background image

1

E3F2-SUS

Cylindrical photoelectric sensor in M18 stainless steel housing

E3F2-SUS

The stainless steel housing provides enhanced 

detergent resistance and longer lifetime in demanding 

environments.

• Complete sensor portfolio in robust stainless steel 

housing

• IP67, IP69K for highest water resistance

• Enhanced detergent resistance (ECOLAB certified)

• High power LED to compensate for dirt and misalign-

ment

Selection Guide

Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adapting the length of the cable 

(e.g. E3F2-R4B4-S-E 5M). For other cable length please contact your OMRON sales representative.

Sensing method

Sensing 
distance

Connection method

Order code

PNP output

NPN output

Through-beam

7 m

2  m

*1

*1.

Pre-wired connectors are available on request. Contact your OMRON representative.

E3F2-7B4-S 2M

E3F2-7C4-S 2M

„

*1

E3F2-7B4-M1-S

E3F2-7C4-M1-S

Retro-reflective with M.S.R.

*2

*2.

Order reflector separately

0.1 to 4 m 
(adjustable)

*3

*3.

Measured with E39-R1S

2  m

*1

E3F2-R4B4-S-E 2M

E3F2-R4C4-S-E 2M

„

*1

E3F2-R4B4-M1-S-E

E3F2-R4C4-M1-S-E

Diffuse-reflective 0.1 m 

(fixed, 

wide beam)

2  m

*1

E3F2-DS10B4-S 2M

E3F2-DS10C4-S 2M

„

*1

E3F2-DS10B4-M1-S

E3F2-DS10C4-M1-S

0.3 m 
(adjustable)

2  m

*1

E3F2-DS30B4-S 2M

E3F2-DS30C4-S 2M

„

*1

E3F2-DS30B4-M1-S

E3F2-DS30C4-M1-S

Diffuse-reflective 
(background suppression)

0.1 m (fixed)

2  m

*1

E3F2-LS10B4-S 2M

E3F2-LS10C4-S 2M

„

*1

E3F2-LS10B4-M1-S

E3F2-LS10C4-M1-S

Summary of Contents for E3F2-7B4-M1-S

Page 1: ...gth please contact your OMRON sales representative Sensing method Sensing distance Connection method Order code PNP output NPN output Through beam 7 m 2 m 1 1 Pre wired connectors are available on request Contact your OMRON representative E3F2 7B4 S 2M E3F2 7C4 S 2M 1 E3F2 7B4 M1 S E3F2 7C4 M1 S Retro reflective with M S R 2 2 Order reflector separately 0 1 to 4 m adjustable 3 3 Measured with E39 ...

Page 2: ...0 x 40 mm enhanced chemical resistance 5 m 100 mm E39 R7 84 mm 6 m 100 mm E39 R8 100 x 100 mm 5 m 100 mm E39 R40 80 x 80 mm Tape Reflectors 0 7 m 150 mm E39 RS1 35 x 10 mm 1 1 m 150 mm E39 RS2 35 x 40 mm 1 4 m 150 mm E39 RS3 80 x 70 mm Lens Cap E39 F31 Mounting Bracket Y92E B18 screw mount Cord Shape Cable type Model Standard Straight 2 m Four wire type M12 connector XS2F D421 D80 A 5 m XS2F D421 ...

Page 3: ...een energized parts and case Vibration resistance 10 to 55 Hz 1 5 mm double amplitude for 2 hrs each direction X Y Z Shock resistance Destruction 500 m s2 each direction X Y Z Degree of protection 1 1 The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure steam cleaning During the test 14 16l min water at 80 C is sprayed onto the sensor from different angles with 8000 ...

Page 4: ...pical sensing distance E39 RS3 E39 R1S E39 R40 E39 R7 E39 R8 20 40 60 80 100 120 0 0 5 10 15 5 10 15 Distance Y mm Distance X mm 140 white paper 50 x 50 mm X Y Object 100 200 300 400 500 600 0 0 10 20 30 40 10 20 30 40 Distance Y mm Distance X mm Sensing distance adjustable between 0 and 550 mm Sensitivity adjusted to maximum Sensitivity adjusted to 400 mm white paper 100 x 100 mm X Y Object 2 4 6...

Page 5: ...0 1000 0 100 10 1 0 1 Excess gain Distance X mm Grey paper 18 reflectivity White paper 90 reflectivity Sensitivity adjusted to maximum Sensing object 100 x 100 mm 0 2 4 6 0 50 100 150 Distance mm Spot diameter mm 20 00 10 00 0 00 10 00 20 00 40 30 20 10 0 10 20 30 40 Incline Angle Sensing Distence movement 20 00 10 00 0 00 10 00 20 00 40 30 20 10 0 10 20 30 40 Incline Angle Sensing Distence moveme...

Page 6: ...lack XS2F D42 D80 XS2F G42 G80 Main circuit 1 2 3 4 1 3 Connector Pin Arrangement 10 to 30 VDC 0 V Brown Blue Power indicator red Incident Interrupted ON OFF ON OFF Operate Release Output indicator red Output transistor Load relay Light indicator Red Main circuit 1 2 3 4 1 2 3 4 Connector Pin Arrangement 10 to 30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink ZD ZD VZ 36 V Stability ...

Page 7: ... OFF Operate Release Output indicator orange Output transistor Load relay Output indicator Stability indicator Orange Main circuit 1 2 3 4 1 2 3 4 Connector Pin Arrangement 10 to 30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink ZD ZD VZ 36 V Green Incident Interrupted ON OFF ON OFF Operate Release Output indicator orange Output transistor Load relay Output indicator Stability indica...

Page 8: ...ngement 10 to 30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink ZD VZ 36 V Stability indicator Green Only on models E3F2 R4C4 and E3F2 D1C4 Incident Interrupted ON OFF ON OFF Operate Release Output indicator red Output transistor Load relay Output indicator Red Main circuit 1 2 3 4 1 2 3 4 Connector Pin Arrangement 10 to 30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink...

Page 9: ... E39 R1S E39 R7 4 8 dia 37 42 3 64 9 Light indicator 16 4 dia 4 dia 4 M18x1 6g 24 27 7 6 2 optical area 37 42 3 Light indicator 4 8 dia 76 16 4 dia M12x1 6g 4 M18x1 6g 24 27 7 6 2 65 5 optical area 37 42 3 49 3 64 9 Light indicator Sensitivity adjustor 4 8 dia 16 4 dia 4 dia 4 M18x1 6g 24 27 7 6 2 optical area 37 42 3 49 3 Light indicator Sensitivity adjustor 4 8 dia 16 4 dia M12x1 6g 4 M18x1 6g 7...

Page 10: ... Y92E B18 Note Hexagon bolt M5 x 32 Material plastic Lens Cap E39 F31 Reflectors f for M3 for M3 9 100 100 92 92 for M3 8 7 84 5 84 5 77 77 80 4 R1 70 0 6 Adhesive tape side 35 10 0 7 Adhesive tape Reflecting surface 4 x R1 40 35 0 7 Adhesive tape Reflecting surface 4 x R1 20 dia 4 max Metal rim Gasket E3F2 Glass plate ...

Page 11: ...nlight 2 Locations subject to condensation due to high humidity 3 Locations subject to corrosive gas 4 Locations where the Sensor may receive direct vibration or shock Connecting and Mounting 1 The maximum power supply voltage is 30 VDC Before turning the power ON make sure that the power supply voltage does not exceed the maximum voltage 2 Laying Sensor wiring in the same conduit or duct as high ...

Page 12: ...listed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems combustion systems railroad sys tems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate in dustry or government regulation...

Reviews: