background image

D-82

Inductive Sensors

Power Reset Time

The Sensor is ready to operate within 300 ms after the Sensor

is turned ON. If the load and Sensor are connected to inde-

pendent power supplies respectively, be sure to turn ON the

Sensor before supplying power to the load.

Power OFF

The Proximity Sensor may output a pulse signal when it is

turned OFF. Therefore, it is recommended that the load be

turned OFF before turning OFF the Proximity Sensor.

Power Supply Transformer

When using a DC power supply, make sure that the DC power

supply has an insulated transformer. Do not use a DC power

supply with an auto-transformer.

Sensing Object

The sensing distance of the Proximity Sensor vary with the

metal coating on sensing objects.

Wiring

High-tension cables

Wiring through Metal Conduit:

If there is power or high-tension line near the cable of the

Proximity Sensor, wire the cable through an independent met-

al conduit to prevent against Proximity Sensor damage or

malfunction.

Mounting

Mounting the Sensor

The Proximity Sensor must be subjected to excessive shock

with a hammer when it is installed, otherwise the Proximity

Sensor may be damaged or lose its water-resistivity.

Maintenance and Inspection

Periodically perform the following checks to ensure stable op-

eration of the Proximity Sensor over a long period of time.

• Check for mounting position, dislocation, looseness or dis-

tortion of the Proximity Sensor and sensing objects.

• Check for loose wiring and connections, improper contacts 

and line breakage.

• Check for attachment or accumulation of metal powder or 

dust.

• Check for abnormal temperature conditions and other envi-

ronmental conditions.

Never disassemble or repair the Sensor.

Environment

Water Resistivity

Do not use the Proximity Sensor underwater, outdoors or in

the rain.

Operating Environment

Be sure to use the Proximity Sensor within its operating ambi-

ent temperature range and do not use the Proximity Sensor

outdoors so that its reliability and life expectancy can be main-

tained. Although the Proximity Sensor is water resistive, a

cover to protect the Proximity Sensor from water or water-sol-

uble machining oil is recommended so that its reliability and

life expectancy can be maintained.

Do not use the Proximity Sensor in an environment with

chemical gas (e.g., strong alkaline or acid gasses including ni-

tric, chromic and concentrated sulfuric acid gases).

Inrush Current

A load that has a large inrush current (e.g., a lamp or motor)

will damage the Proximity Snesor, in this case connect the

load to the Proximity Sensor through a Relay

E2Q4-N40M

##

- M1

150

Mutual Interference  (Unit: mm)

Model

Length

A

A

Side-by-side

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. 

D02E-EN-01A

F502-EN2-04.book  Seite 82  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for E2Q4

Page 1: ... Y axis 15 X axis 90 incremets Square Proximity Sensor Ordering Information DC type Sensing distance Connection Active face Output NO NO NC 20 mm shielded Plug in connector Changable NPN E2Q4 N20E1 M1 E2Q4 N20E3 M1 PNP E2Q4 N20F1 M1 E2Q4 N20F3 M1 30 mm non shielded NPN E2Q4 N30ME1 M1 E2Q4 N30ME3 M1 PNP E2Q4 N30MF1 M1 E2Q4 N30MF3 M1 40 mm non shielded NPN E2Q4 N40ME3 M1 PNP E2Q4 N40MF3 M1 ...

Page 2: ...P NO NC Load 200 mA max On stage voltage drop 3 VDC max at 200 mA load current Circuit protection Reverse polarity output short circuit Indicator Operating indicator yellow LED operating voltage green LED Ambient temperature Operating 25 to 70 C Ambient humidity 35 to 95 RH Influence of temperature 10 max of Sn at 23 in temperature range of 25 to 70 C Dielectric strength 1 500 VAC 50 60 Hz for 1 m...

Page 3: ...ing distance Sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output Load Brown Black Blue V 0 V Proximity Sensor main circuits 4 7kΩ Operation Indicator yellow 3 1 2 4 sensing Sensing object 100 0 Rated distance Sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output NO ON OFF Control output NC White NC Load Load Brown Blac...

Page 4: ...ted sensing distance Sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output Load Brown Black Blue V 0 V Proximity Sensor main circuits 4 7kΩ Operation Indicator yellow 3 1 2 4 sensing Sensing object 100 0 Rated distance Sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output NO ON OFF Control output NC White NC Load Load Br...

Page 5: ... distance between the Sensor and the sur rounding metal as shown in the table below Mutual Interference If more than one Sensor is located in parallel ensure to main tain enough space between adjacent Sensors to suppress mutual interference as provided in the following diagram Connection type Method Description AND serial connection The Sensors connected together must satisfy the following conditi...

Page 6: ...tion dislocation looseness or dis tortion of the Proximity Sensor and sensing objects Check for loose wiring and connections improper contacts and line breakage Check for attachment or accumulation of metal powder or dust Check for abnormal temperature conditions and other envi ronmental conditions Never disassemble or repair the Sensor Environment Water Resistivity Do not use the Proximity Sensor...

Reviews: