background image

D-163

E2EZ

E2

E

Z

Rating/performance

Model

E2EZ-X4C1
E2EZ-X4Y1

E2EZ-X8C1
E2EZ-X8Y1

E2EZ-X4D

@

-N

E2EZ-X4D

@

-M1J

E2EZ-X4D

@

-M1GJ

E2EZ-X8D

@

-N

E2EZ-X8D

@

-M1J

E2EZ-X8D

@

-M1GJ

Item

Sensing distance

4 mm 

±

10%

8 mm 

±

10%

4 mm 

±

10%

8 mm 

±

10%

Setting distance*1

*1. Use within a range where the green indicator is lit.

0 to 3.2 mm

0 to 6.4 mm

0 to 3.2 mm

0 to 6.4 mm

Differential distance

20% max. of sensing distance

Sensing object

Ferrous metal (Sensitivity lowers with non-ferrous metals)

Standard sensing 
object

Iron, 30 

×

 30 

×

 1 mm

Iron, 54 

×

 54 

×

 1 mm

Iron, 30 

×

 30 

×

 1 mm

Iron, 54 

×

 54 

×

 1 mm

Response 
frequency*2

*2. The response frequencies for DC switching are average values measured on condition that the distance between each sensing object is twice as large as the size

of the sensing object and the sensing distance set is half of the maximum sensing distance.

C models: 12 Hz
Y models: 5 Hz

C models: 8 Hz
Y models: 5 Hz

100 Hz

30 Hz

Rated supply voltage 
(operating voltage)

C models: 12 to 24 VDC, ripple (p-p) : 10% max., (10 to 
30 VDC)

12 to 24 VDC (10 to 30 VDC) ripple (p-p): 10% max.

Current consumption

C models: 15 mA max.

---

Leakage current

Y models: 2 mA max. (at 100 VAC), 3 mA max. (at 200 
VAC)

0.8 mA max.

Control 
output

Switching 
capacity

C models: NPN open collector output 12 VDC 100 mA 
max. (30 VDC max.)
Y models: 10 to 200 mA

3 to 100 mA

Residual 
voltage

C models: 2 V max. (load current: 200 mA with cable 
length: 2 m) 
Y models: Refer to the Specifications

3.0 V max. (under load current of 100 mA with cable 
length of 2 m)

Indicator lamp

C models: Detection indicator (red LED) 
Y models: Operation indicator (red LED)

D1 models: Operation indicator (red LED), Operation 
set indicator (green LED) D2 models: Operation indica-
tor (red LED)

Operating status (with 
sensing object ap-
proaching)

NO

D1 models: NO
D2 models: NC
NO

Protective circuits

C models: Reverse connection protection, load short-
circuit protection, surge absorber Y models: None

Surge absorber, short-circuit protection

Ambient temperature

Operating/Storage: 0

°

C to 50

°

C (with no icing or condensation)

Ambient humidity

Operating/Storage: 35% to 95%RH (with no condensation)

Temperature influ-
ence

±

20% max. of sensing distance within a temperature range of 0

°

C to 50

°

C based on the sensing distance at a 

temperature of 23

°

C.

Voltage influence

E models: 

±

2.5% max. of sensing distance within a 

range of 

±

10% of rated power supply voltage

Y models: 

±

1% max. of sensing distance within a range 

of 

±

10% of rated power supply voltage

±

2.5% max. of sensing distance within a range of 

±

10% 

of rated power supply voltage

Insulation resistance

50 M

 min. (at 500 VDC) between current carry parts and case

Dielectric strength

C type: 1,000 VAC, 50/60 Hz for 1 min.
                                                                

1000 VAC 50/60 Hz for 1 min between current carrying 
part and case

Vibration resistance

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 1,000 m/s

2

 for 10 times each in X, Y, and Z directions

Protective structure

IEC60529 IP67

Connection method

Pre-wired (standard length: 2 m) Connector Extension Models

Weight (Packed state) Approx. 170 g

Approx. 270 g

E2EZ-X4D

@

-N Approx. 

160 g
E2EZ-X4D

@

-M1J Approx. 

90 g
E2EZ-X4D

@

-M1GJ Ap-

prox. 90 g

E2EZ-X8D

@

-N Approx. 

220 g
E2EZ-X8D

@

-M1J Approx. 

160 g
E2EZ-X8D

@

-M1G Ap-

prox. 160 g

Material

Case: Brass, Sensing face: Heat-resistant ABS resin
Screw: Brass, Mounting nut: Steel

Accessories

Instruction manual

)

F502-EN2-04.book  Seite 163  Dienstag, 26. Juli 2005  5:48 17

Reviews: