![background image](http://html1.mh-extra.com/html/omron/e2ez/e2ez_datasheet_740874003.webp)
D-163
E2EZ
E2
E
Z
Rating/performance
Model
E2EZ-X4C1
E2EZ-X4Y1
E2EZ-X8C1
E2EZ-X8Y1
E2EZ-X4D
@
-N
E2EZ-X4D
@
-M1J
E2EZ-X4D
@
-M1GJ
E2EZ-X8D
@
-N
E2EZ-X8D
@
-M1J
E2EZ-X8D
@
-M1GJ
Item
Sensing distance
4 mm
±
10%
8 mm
±
10%
4 mm
±
10%
8 mm
±
10%
Setting distance*1
*1. Use within a range where the green indicator is lit.
0 to 3.2 mm
0 to 6.4 mm
0 to 3.2 mm
0 to 6.4 mm
Differential distance
20% max. of sensing distance
Sensing object
Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing
object
Iron, 30
×
30
×
1 mm
Iron, 54
×
54
×
1 mm
Iron, 30
×
30
×
1 mm
Iron, 54
×
54
×
1 mm
Response
frequency*2
*2. The response frequencies for DC switching are average values measured on condition that the distance between each sensing object is twice as large as the size
of the sensing object and the sensing distance set is half of the maximum sensing distance.
C models: 12 Hz
Y models: 5 Hz
C models: 8 Hz
Y models: 5 Hz
100 Hz
30 Hz
Rated supply voltage
(operating voltage)
C models: 12 to 24 VDC, ripple (p-p) : 10% max., (10 to
30 VDC)
12 to 24 VDC (10 to 30 VDC) ripple (p-p): 10% max.
Current consumption
C models: 15 mA max.
---
Leakage current
Y models: 2 mA max. (at 100 VAC), 3 mA max. (at 200
VAC)
0.8 mA max.
Control
output
Switching
capacity
C models: NPN open collector output 12 VDC 100 mA
max. (30 VDC max.)
Y models: 10 to 200 mA
3 to 100 mA
Residual
voltage
C models: 2 V max. (load current: 200 mA with cable
length: 2 m)
Y models: Refer to the Specifications
3.0 V max. (under load current of 100 mA with cable
length of 2 m)
Indicator lamp
C models: Detection indicator (red LED)
Y models: Operation indicator (red LED)
D1 models: Operation indicator (red LED), Operation
set indicator (green LED) D2 models: Operation indica-
tor (red LED)
Operating status (with
sensing object ap-
proaching)
NO
D1 models: NO
D2 models: NC
NO
Protective circuits
C models: Reverse connection protection, load short-
circuit protection, surge absorber Y models: None
Surge absorber, short-circuit protection
Ambient temperature
Operating/Storage: 0
°
C to 50
°
C (with no icing or condensation)
Ambient humidity
Operating/Storage: 35% to 95%RH (with no condensation)
Temperature influ-
ence
±
20% max. of sensing distance within a temperature range of 0
°
C to 50
°
C based on the sensing distance at a
temperature of 23
°
C.
Voltage influence
E models:
±
2.5% max. of sensing distance within a
range of
±
10% of rated power supply voltage
Y models:
±
1% max. of sensing distance within a range
of
±
10% of rated power supply voltage
±
2.5% max. of sensing distance within a range of
±
10%
of rated power supply voltage
Insulation resistance
50 M
Ω
min. (at 500 VDC) between current carry parts and case
Dielectric strength
C type: 1,000 VAC, 50/60 Hz for 1 min.
1000 VAC 50/60 Hz for 1 min between current carrying
part and case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 1,000 m/s
2
for 10 times each in X, Y, and Z directions
Protective structure
IEC60529 IP67
Connection method
Pre-wired (standard length: 2 m) Connector Extension Models
Weight (Packed state) Approx. 170 g
Approx. 270 g
E2EZ-X4D
@
-N Approx.
160 g
E2EZ-X4D
@
-M1J Approx.
90 g
E2EZ-X4D
@
-M1GJ Ap-
prox. 90 g
E2EZ-X8D
@
-N Approx.
220 g
E2EZ-X8D
@
-M1J Approx.
160 g
E2EZ-X8D
@
-M1G Ap-
prox. 160 g
Material
Case: Brass, Sensing face: Heat-resistant ABS resin
Screw: Brass, Mounting nut: Steel
Accessories
Instruction manual
)