![background image](http://html1.mh-extra.com/html/omron/e2c-c1a/e2c-c1a_manual_740823005.webp)
E2C
E2C
5
Operation
Output Circuits
Main
circuit
50 mA max.
2.2
Ω
47 V
Output (+)
Output (–)
E2C-AK4A (AC-switching Amplifier Unit)
Note:
Relay contact output is incorporated.
Main
circuit
2.2
Ω
47 V
47 V
200 mA max.
12 to 24 VDC
Output 1 (PNP)
Output 2 (NPN)
0 V
E2C-AM4A (DC-switching Amplifier Unit)
E2C-GE4
j
(DC-switching Amplifier Unit)
E2C-GF4
j
(DC-switching Amplifier Unit)
Main
circuit
4.7 k
Ω
47 V
100 mA
max.
12 to 24 VDC
Output
0 V
2.2
Ω
Main
circuit
4.7 k
Ω
47 V
100 mA max.
12 to 24 VDC
Output
0 V
2.2
Ω
E2C-JC4A (DC-switching Amplifier Unit)
E2C-JC4AP
Main
circuit
12 to 24 VDC
Brown (Red)
Output
Black (White)
0 V
Blue (Black)
47 V
2.2
Ω
Load
12 to
24 VDC
100 mA
max.
0 V
Brown (Red)
Black
(White)
Output
Blue (Black)
Orange (Yellow)
Self-diagnostic
output (50 mA
max.)
Operation
indicator
Stability
indicator
(Red)
(Green)
2.2
Ω
3.9
Ω
Z
D
: V
Z
=40 V
Main
circuit
Note:
Voltage output from E2C-GE4
j
will be available if the operation selector
is set to NC. When using voltage output, be sure to reset the E2C-GE4
j
after the E2C-GE4
j
is turned on, at which moment the E2C-GE4
j
gen-
erates a pulse for approximately 60 ms. No such pulse is generated from
the E2C-GF4 with PNP output.
100 mA max.
E2C-WH4A (DC-switching Amplifier Unit)
E2C-WH4AF
(DC-switching Amplifier Unit with Connector Output)
Main
circuit
12 to 24 VDC
0 V
2.2
Ω
2.2
Ω
47 V
47 V
200 mA max.
Output 2 (PNP)
Output 1 (NPN)
12 to 24 VDC
0 V
2.2
Ω
2.2
Ω
47 V
47 V
200 mA max.
Output 2 (PNP)
Output 1 (NPN)
2.2
Ω
47 V
50 mA max.
Connector output
Main
circuit