Safety Precautions

Power Supply

Do not impose an excessive voltage on the E2AX, otherwise it may
be damaged. Do not impose AC current (100 to 240 VAC) on any DC
model, otherwise it may be damaged.

Load Short-circuit

Do not short-circuit the load, or the E2AX may be damaged.

The E2AX’s short-circuit protection function will be valid if the polarity
of the supply voltage imposed is correct and within the rated voltage
range.

Wiring

Be sure to wire the E2AX and load correctly, otherwise it may be
damaged.

Connection with No Load

Be sure to insert loads when wiring. Make sure to connect a proper
load to the E2AX in operation, otherwise it may damage internal ele-
ments.

Do not expose the product to flammable or explo-
sive gases.

Do not disassemble, repair, or modify the product.

Correct Use

Designing

Power Reset Time

The Proximity Sensor is ready to operate within 100 ms (160ms for
NO+NC -B3 / -C3 types) after power is supplied. If power supplies
are connected to the Proximity Sensor and load respectively, be sure
to supply power to the Proximity Sensor before supplying power to
the load.

Effects of Surrounding Metal

When mounting the E2AX within a metal panel, ensure that the
clearances given in the following table are maintained. 

(Unit: mm)

Note 1.

In the case of using the supplied nuts. If true flash mounting 
is necessary, apply a free zone of 1.5 mm.

2.

In the case of using the supplied nuts. If true flush mounting 
is necessary, apply a free zone of 4 mm.

7

4

56

70

17

M12

×

1

M12

×

1

9.2 dia.

4

56

70

7

7

17

M12

×

1

M12

×

1

10

24

4

61

75

M18

×

1

M12

×

1

24

10

4

61

75

10

15.1 dia.

M18

×

1

M12

×

1

66

5

80

36

10

M30

×

1.5

M12

×

1

10

5

15

66

80

36

26.6 dia.

M30

×

1.5

Note:

Operation indicator (yellow LED, 4

×

90

°

)

Note:

Operation indicator (yellow LED, 4

×

90

°

)

Note:

Operation indicator (yellow LED, 4

×

90

°

)

Note:

Operation indicator (yellow LED, 4

×

90

°

)

Note:

Operation indicator (yellow LED, 4

×

90

°

)

Note:

Operation indicator (yellow LED, 4

×

90

°

)

E2AX-M12LS04-M1-

@@ 

E2AX-S12LS04-M1-@

E2AX-M18LS08-M1-

@@

E2AX-S18LS08-M1-@

E2AX-M30LS15-M1-

@@

E2AX-S30LS15-M1-@

E2AX-M12LN08-M1-

@@

E2AX-S12LN08-M1-@

E2AX-M18LN16-M1-

@@

E2AX-S18LN16-M1-@

E2AX-M30LN30-M1-

@@

E2AX-S30LN30-M1-@

Two, clamping nuts

Indicator (See note.)

Two, clamping nuts

Indicator (See note.)

Two, clamping nuts

Indicator (See note.)

Two, clamping nuts

Indicator (See note.)

Two, clamping nuts

Indicator (See note.)

Two, clamping nuts

Indicator (See note.)

l

m

n

m

D

d dia.

l

Type

Dimension

M12

M18

M30

Short 

barrel

Long 

barrel

Shielded

l

0


(See note 1.)


(See note 2.)

m

12

24

45

d

---

27

45

D

0

1.5

4

n

18

27

45

Non-
shielded

l

15

22

30

40

m

20

48

70

90

d

40

70

90

120

D

15

22

30

40

n

40

70

90

120

Summary of Contents for E2AX -

Page 1: ...08 M1 B3 NPN E2AX M12KN08 M1 C1 E2AX M12KN08 M1 C2 E2AX M12KN08 M1 C3 56 70 PNP E2AX M12LN08 M1 B1 E2AX M12LN08 M1 B2 E2AX M12LN08 M1 B3 NPN E2AX M12LN08 M1 C1 E2AX M12LN08 M1 C2 E2AX M12LN08 M1 C3 M18 Shiel ded 8 0 mm M12 connector Brass 2 39 53 PNP E2AX M18KS08 M1 B1 E2AX M18KS08 M1 B2 E2AX M18KS08 M1 B3 NPN E2AX M18KS08 M1 C1 E2AX M18KS08 M1 C2 E2AX M18KS08 M1 C3 61 75 PNP E2AX M18LS08 M1 B1 E2...

Page 2: ... S Cylindrical metric threaded stainless steel 4 Housing size 08 8 mm 12 12 mm 18 18 mm 30 30 mm 5 Barrel length K Standard length L Long body 6 Shield S Shielded N Non shielded 7 Sensing distance Numeral Sensing distance e g 02 2 mm 16 16 mm 8 Kind of connection M1 M12 connector 4 pin M3 M8 connector 4 pin M5 M8 connector 3 pin 9 Power source and output B DC 3 wire PNP open collector C DC 3 wire ...

Page 3: ...able length of 2 m Indicator Operation indicator Yellow LED Operation mode with sensing object approaching B1 C1 models NO B2 C2 models NC B3 C3 models NO NC For details refer to the timing charts Protection circuit Output reverse polarity protection Power source circuit reverse polarity protection Surge suppressor Short circuit protection Ambient air temperature Operating 40 C to 70 C Storage 40 ...

Page 4: ...dels PNP open collector C models NPN open collector Control output Load current See note 2 200 mA max 32 VDC max Residual voltage 2 V max under load current of 200 mA with cable length of 2 m Indicator Operation indicator Yellow LED Operation mode with sensing object approaching B1 C1 models NO B2 C2 models NC B3 C3 models NO NC For details refer to the timing charts Protection circuit Output reve...

Page 5: ...dicator Yellow Setting indicator Red NC type Operation indicator Yellow Operation mode D1 models NO D2 models NC Protection circuit Surget suppressor Short circuit protection Ambient temperature Operating 40 C to 70 C Storage 40 C to 85 C with no icing or condensation Temperature influence 10 max of sensing distance at 23 C within temperature range of 25 C to 70 C 15 max of sensing distance at 23 ...

Page 6: ...Load current See note 2 3 to 100 mA Residual voltage 3 V max under load current of 100 mA with cable length of 2 m Indicator see timing chart NO type Operation indicator Yellow Setting indicator Red NC type Operation indicator Yellow Operation mode D1 models NO D2 models NC Protection circuit Surget suppressor Short circuit protection Ambient temperature Operating 40 C to 70 C Storage 40 C to 85 C...

Page 7: ... N16 E2A M12 N08 E2A M30KN20 5 0 4 0 3 0 2 0 1 0 0 d t 1 mm X 5 10 15 20 25 30 35 0 1 0 2 0 3 0 4 0 5 0 7 0 8 0 6 0 10 20 30 40 50 60 d t 1 mm X 0 4 8 12 16 20 10 20 30 40 50 60 70 80 d t 1 mm X Side length of sensing object d mm Brass Iron Sensing distance X mm Stainless steel SUS303 Aluminum Copper Side length of sensing object d mm Brass Iron Sensing distance X mm Copper Stainless steel SUS303 ...

Page 8: ...m Stainless steel SUS303 Copper E2AX M18 N16 E2A S18 N16 Side length of sensing object d mm Sensing distance X mm Iron Copper Brass Aluminum E2AX M30LN30 E2A S30LN30 Side length of sensing object d mm Sensing distance X mm Iron Copper Brass Stainless steel SUS303 Stainless steel SUS303 Aluminum Side length of sensing object d mm Sensing distance X mm 25 20 15 10 5 0 20 40 60 80 100 t 1 mm d X Copp...

Page 9: ...ot used Proximity Sensor main circuits 100 0 Sensing object Rated sensing distance Sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output 3 1 2 4 Load See note 1 V 0 V M12 Connector Pin Arrangement See note Note Pin 4 of the M12 connector is not used Proximity Sensor main circuits Sensing object 100 0 Rated sensing distance Sensing zone Non sensing zone Proxim...

Page 10: ...12 Connector Pin Arrangement See note 100 0 Sensing object Rated sensing distance Sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output Load See note 1 V 0 V Note Pin 4 of the M12 connector is not used Proximity Sensor main circuits 3 1 2 4 M12 Connector Pin Arrangement See note Sensing object 100 0 Rated sensing distance Sensing zone Non sensing zone Proximi...

Page 11: ...Proximity Sensor ON OFF ON OFF ON OFF Yellow indicator Red indicator Control output Load Brown Blue V 0 V Load can be connected to V or 0V side 3 1 2 4 M12 Connector Pin Arrangement 100 0 Sensing object Rated sensing distance Sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output Load Brown Blue V 0 V Load can be connected to V or 0V side 3 1 2 4 M12 Connector...

Page 12: ... Note 1 Operation indicator yellow LED 4 90 Note 2 for NO NC B3 C3 models the total length is 4 mm longer Note 1 Operation indicator yellow LED 4 90 Note 2 for NO NC B3 C3 models the total length is 4 mm longer Note Operation indicator yellow LED 4 90 Note Operation indicator yellow LED 4 90 Note Operation indicator yellow LED 4 90 Two clamping nuts Indicator See note Two clamping nuts Indicator S...

Page 13: ...tal When mounting the E2AX within a metal panel ensure that the clearances given in the following table are maintained Unit mm Note 1 In the case of using the supplied nuts If true flash mounting is necessary apply a free zone of 1 5 mm 2 In the case of using the supplied nuts If true flush mounting is necessary apply a free zone of 4 mm 7 4 56 70 17 M12 1 M12 1 9 2 dia 4 56 70 7 7 17 M12 1 M12 1 ...

Page 14: ...re conditions and other environ mental conditions 5 Check for proper lighting of indicators for models with a set indi cator Never disassemble or repair the Sensor Environment Water Resistivity The Proximity Sensors are tested intensively on water resistance but in order to ensure maximum performance and life expectancy avoid immersion in water and provide protection from rain or snow Operating En...

Reviews: