Precautions

Safety Precautions

Power Supply

Do not impose an excessive voltage on the E2A, otherwise it may be
damaged. Do not impose AC current (100 to 240 VAC) on any DC
model, otherwise it may be damaged.

Load Short-circuit

Do not short-circuit the load, or the E2A may be damaged.

The E2A’s short-circuit protection function will be valid if the polarity
of the supply voltage imposed is correct and within the rated voltage
range.

Wiring

Be sure to wire the E2A and load correctly, otherwise it may be dam-
aged.

Connection with No Load

Be sure to insert loads when wiring. Make sure to connect a proper
load to the E2A in operation, otherwise it may damage internal ele-
ments.

Do not expose the product to flammable or explo-
sive gases.

Do not disassemble, repair, or modify the product.

Correct Use

Designing

Power Reset Time

The Proximity Sensor is ready to operate within 100 ms (160ms for
NO+NC -B3 / -C3 types) after power is supplied. If power supplies
are connected to the Proximity Sensor and load respectively, be sure
to supply power to the Proximity Sensor before supplying power to
the load.

Effects of Surrounding Metal

When mounting the E2A within a metal panel, ensure that the clear-
ances given in the following table are maintained. 

(Unit: mm)

Note 1.

In the case of using the supplied nuts. 
If true flash mounting is necessary, apply a free zone of 
1.5 mm.

2.

In the case of using the supplied nuts. 
If true flush mounting is necessary, apply a free zone of 
4 mm.

Power OFF

The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.

Power Supply Transformer

When using a DC power supply, make sure that the DC power sup-
ply has an insulated transformer. Do not use a DC power supply with
an auto-transformer.

Mutual Interference

When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.

(Unit: mm)

Type

Dimension

M8

M12

M18

M30

Short 

barrel

Long 

barrel

Shielded

l

0

0


(See note 1.)


(See note 2.)

m

4.5

12

24

45

d

---

---

27

45

D

0

0

1.5

4

n

12

18

27

45

Non-
shielded

l

12

15

22

30

40

m

8

20

48

70

90

d

24

40

70

90

120

D

12

15

22

30

40

n

24

40

70

90

120

l

m

n

m

D

d dia.

l

Type

Dimension

M8

M12

M18

M30

Short 

barrel

Long 

barrel

Shielded

A

20

30

60

110

B

15

20

35

70

Non-shiel-
ded

A

80

120

200

300

300

B

60

100

120

200

300

Summary of Contents for E2A -

Page 1: ...A S08KS02 M1 C1 E2A S08KS02 M1 C2 49 65 PNP E2A S08LS02 M1 B1 E2A S08LS02 M1 B2 NPN E2A S08LS02 M1 C1 E2A S08LS02 M1 C2 M8 connector 3 pin 27 39 PNP E2A S08KS02 M5 B1 E2A S08KS02 M5 B2 NPN E2A S08KS02...

Page 2: ...34 48 PNP E2A M12KN08 M3 B1 E2A M12KN08 M3 B2 n a NPN E2A M12KN08 M3 C1 E2A M12KN08 M3 C2 n a 56 70 PNP E2A M12LN08 M3 B1 E2A M12LN08 M3 B2 n a NPN E2A M12LN08 M3 C1 E2A M12LN08 M3 C2 n a M18 Shiel de...

Page 3: ...C1 E2A M30LS15 M5 C2 n a M8 connector 4 pin Brass 3 44 58 PNP E2A M30KS15 M3 B1 E2A M30KS15 M3 B2 n a NPN E2A M30KS15 M3 C1 E2A M30KS15 M3 C2 n a 66 80 PNP E2A M30LS15 M3 B1 E2A M30LS15 M3 B2 n a NPN...

Page 4: ...erial PVC dia 4mm WP Other available cable materials and sizes PVC dia 6mm WS PUR PVC PUR jacket dia 4mm WA PUR PVC PUR jacket dia 6mm WB PVC robotic cable dia 4mm WR Pre wired models with cable end c...

Page 5: ...WP pre wired PVC dia 4mm standard WS pre wired PVC dia 6mm WR pre wired PVC robotic cable dia 4mm WA pre wired PUR PVC PUR jacket dia 4mm WB pre wired PUR PVC PUR jacket dia 6mm M1 M12 connector 4 pin...

Page 6: ...s NO B2 C2 models NC B3 C3 models NO NC For details refer to the timing charts See note 4 Protection circuit Power source circuit reverse polarity protection Surge suppressor Short circuit protection...

Page 7: ...ator Operation indicator Yellow LED Operation mode with sensing object approaching B1 C1 models NO B2 C2 models NC B3 C3 models NO NC For details refer to the timing charts Protection circuit Output r...

Page 8: ...odels NC Protection circuit Surget suppressor Short circuit protection Ambient temperature Operating 40 C to 70 C Storage 40 C to 85 C with no icing or condensation Temperature influence 10 max of sen...

Page 9: ...tor Yellow Setting indicator Red NC type Operation indicator Yellow Operation mode D1 models NO D2 models NC Protection circuit Surget suppressor Short circuit protection Ambient temperature Operating...

Page 10: ...h of sensing object d mm Iron d t 1 mm X 0 5 1 0 1 5 2 0 2 5 5 0 4 0 3 0 2 0 1 0 0 d t 1 mm X 5 10 15 20 25 30 35 0 1 0 2 0 3 0 4 0 5 0 7 0 8 0 6 0 10 20 30 40 50 60 d t 1 mm X 0 4 8 12 16 20 10 20 30...

Page 11: ...gth of sensing object d mm Sensing distance X mm Iron Brass Aluminum Stainless steel SUS303 Copper E2A M18 N16 E2A S18 N16 Side length of sensing object d mm Sensing distance X mm Iron Copper Brass Al...

Page 12: ...main circuits 1 2 4 3 100 0 Sensing object Rated sensing distance Sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output 3 1 2 4 Load Brown Black See note 1 Blue...

Page 13: ...2 1 2 4 3 100 0 Sensing object Rated sensing distance Sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output Load Brown Black See note 1 Blue V 0 V Note 1 With M8...

Page 14: ...Proximity Sensor ON OFF ON OFF ON OFF Yellow indicator Red indicator Control output Load Brown Blue V 0 V Load can be connected to V or 0V side 3 1 2 4 M12 Connector Pin Arrangement 100 0 Sensing obj...

Page 15: ...ated round cable with 3 conductors conductor cross section 0 3 mm2 insulator diameter 1 3 mm standard length 2 m 2 Operation indicator yellow Two clamping nuts Indicator See note 2 Note 1 4 dia vinyl...

Page 16: ...ator diameter 1 3 mm standard length 2 m 2 Operation indicator yellow Note 1 4 dia vinyl insulated round cable with 3 conductors conductor cross section 0 3 mm2 insulator diameter 1 3 mm standard leng...

Page 17: ...90 Note 2 for NO NC B3 C3 models the total length is 4 mm longer Note 1 Operation indicator yellow LED 4 90 Note 2 for NO NC B3 C3 models the total length is 4 mm longer Note Operation indicator yello...

Page 18: ...8LN16 M1 E2A S18LN16 M1 E2A M30LN30 M1 E2A S30LN30 M1 Two clamping nuts Indicator See note Two clamping nuts Indicator See note Two clamping nuts Indicator See note Two clamping nuts Indicator See not...

Page 19: ...ects of Surrounding Metal When mounting the E2A within a metal panel ensure that the clear ances given in the following table are maintained Unit mm Note 1 In the case of using the supplied nuts If tr...

Page 20: ...t Water Resistivity The Proximity Sensors are tested intensively on water resistance but in order to ensure maximum performance and life expectancy avoid immersion in water and provide protection from...

Reviews: