background image

F-140

Special-purpose Basic Switch 

DZ

Specifications

Approved Standards

Approved Standard Ratings

UL508 (File No. E41515)/
CSA C22.2 No. 55 (File No. LR21642)

Ratings

Note: 1.

Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).

2.

Lamp load has an inrush current of 10 times the steady-state current.

3.

Motor load has an inrush current of 6 times the steady-state current.

Characteristics

Note: 1.

The values are for pin plunger models. (Contact your OMRON representative for other models.)

2.

Malfunction: 1 ms max.

Contact Form (DPDT)

Agency

Standard

File No.

UL

UL508

E41515

CSA

CSA C22.2 No. 55

LR21642

Rated voltage

DZ-10G

125 VAC

10 A 1/3 HP

250 VAC

10 A 1/4 HP

480 VAC

2 A

125 VDC

0.5 A

250 VDC

0.25 A

Rated voltage

Non-inductive load

Inductive load

Inrush current

Resistive load

Lamp load

Inductive load

Motor load

NC

NO

NC

NO

NC

NO

NC

NO

NC

NO

125 VAC
250 VAC

10 A
10 A

2 A
1.5 A

1 A
0.7 A

6 A
4 A

3 A
2 A

1.5 A
1 A

30 A max.

15 A max.

8 VDC
14 VDC
30 VDC

10 A
10 A
10 A

3 A
3 A
3 A

1.5 A
1.5 A
1.5 A

6 A
6 A
4 A

5 A
5 A
3 A

2.5 A
2.5 A
1.5 A

125 VAC

0.5 A 

0.5 A

0.05 A

0.05 A

250 VDC

0.25 A

0.25 A

0.03 A

0.03 A

Operating speed

0.1 mm to 1 m/s (at pin plunger)

Operating frequency

Mechanical: 240 operations/min
Electrical:

20 operations/min

Insulation resistance

100 M

 min. (at 500 VDC)

Contact resistance

15 m

 max. (initial value)

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between non-continuous terminals
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal part, 
and between current-carrying metal part and ground and between switches

Vibration resistance

Malfunction: 10 to 55 Hz, 1.5-mm double amplitude

Shock resistance

Destruction: 1,000 m/s

2

 {approx. 100G} max.

Malfunction: 300 m/s

2

 {approx. 30G} max. (See notes 1 and 2.)

Durability

Mechanical: 1,000,000 operations min.
Electrical:

500,000 operations min.

Ambient temperature

Operating: 

25

°

C to 80

°

C (with no icing)

Ambient humidity

Operating: 35% to 85% max.

Weight

Approx. 30 to 50 g

COM1

COM2

NC1

NO1

NC2

NO2

Summary of Contents for DZ

Page 1: ...Legend 1 Ratings 10 10 A 250 VAC 2 Contact Gap G 0 5 mm 3 Actuator None Pin plunger V Hinge lever V22 Short hinge roller lever V2 Hinge roller lever W Hinge lever W22 Short hinge roller lever W2 Hinge roller lever 4 Contact Form 1 DPDT 5 Terminals A Solder terminal B Screw terminal Ordering Information List of Models 1 2 3 4 5 DZ 10G 1 Actuator OT Solder terminal Screw terminal 0 13 mm min DZ 10G ...

Page 2: ...7 A 6 A 4 A 3 A 2 A 1 5 A 1 A 30 A max 15 A max 8 VDC 14 VDC 30 VDC 10 A 10 A 10 A 3 A 3 A 3 A 1 5 A 1 5 A 1 5 A 6 A 6 A 4 A 5 A 5 A 3 A 2 5 A 2 5 A 1 5 A 125 VAC 0 5 A 0 5 A 0 05 A 0 05 A 250 VDC 0 25 A 0 25 A 0 03 A 0 03 A Operating speed 0 1 mm to 1 m s at pin plunger Operating frequency Mechanical 240 operations min Electrical 20 operations min Insulation resistance 100 MΩ min at 500 VDC Conta...

Page 3: ...6 mm 0 4 mm 1 7 mm OP 18 3 1 mm 100 000 70 000 50 000 30 000 10 000 1 000 7 000 5 000 3 000 2 000 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 10 000 7 000 5 000 3 000 1 000 700 500 300 100 0 5 15 10 Durability x10 3 operations Durability x10 3 operations 125 VAC cosφ 1 250 VAC cosφ 1 Overtravel mm Switching current A Without load Operating frequency 240 operations minute Operating frequency 20 operations mi...

Page 4: ... Short Hinge Roller Lever DZ 10GW22 1B 9 5 dia 4 plastic roller t 1 stainless steel lever 4 36 0 1 dia 0 05 4 2 0 075 dia hole 0 025 17 45 0 2 49 2 11 9 25 4 0 1 8 2 19 7 17 7 14 5 OP 30 2R 4 2 0 075 0 025 1 1 PT DZ 10GV22 1B 4 36 0 1 dia 0 05 9 5 dia 4 plastic roller t 1 Stainless steel lever 4 2 0 075 dia hole 0 025 4 2 0 075 0 025 48 4R 19 7 17 7 49 2 11 9 14 5 OP FP 28 4 25 4 0 1 17 45 0 2 8 2...

Page 5: ...witching frequency is too high the contact may not catch up with the speed The rated permissible switching speed and frequency indicate the switching reliability of the Switch The life of a Switch is determined at the specified switching speed The life varies with the switching speed and frequency even when they are within the permissible ranges In order to determine the life of a Switch model to ...

Page 6: ... interest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No B060 E1 07 ...

Reviews: