![background image](http://html1.mh-extra.com/html/omron/dz/dz_datasheet_1633475002.webp)
F-140
Special-purpose Basic Switch
DZ
Specifications
■
Approved Standards
■
Approved Standard Ratings
UL508 (File No. E41515)/
CSA C22.2 No. 55 (File No. LR21642)
■
Ratings
Note: 1.
Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
2.
Lamp load has an inrush current of 10 times the steady-state current.
3.
Motor load has an inrush current of 6 times the steady-state current.
■
Characteristics
Note: 1.
The values are for pin plunger models. (Contact your OMRON representative for other models.)
2.
Malfunction: 1 ms max.
■
Contact Form (DPDT)
Agency
Standard
File No.
UL
UL508
E41515
CSA
CSA C22.2 No. 55
LR21642
Rated voltage
DZ-10G
125 VAC
10 A 1/3 HP
250 VAC
10 A 1/4 HP
480 VAC
2 A
125 VDC
0.5 A
250 VDC
0.25 A
Rated voltage
Non-inductive load
Inductive load
Inrush current
Resistive load
Lamp load
Inductive load
Motor load
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
125 VAC
250 VAC
10 A
10 A
2 A
1.5 A
1 A
0.7 A
6 A
4 A
3 A
2 A
1.5 A
1 A
30 A max.
15 A max.
8 VDC
14 VDC
30 VDC
10 A
10 A
10 A
3 A
3 A
3 A
1.5 A
1.5 A
1.5 A
6 A
6 A
4 A
5 A
5 A
3 A
2.5 A
2.5 A
1.5 A
125 VAC
0.5 A
0.5 A
0.05 A
0.05 A
250 VDC
0.25 A
0.25 A
0.03 A
0.03 A
Operating speed
0.1 mm to 1 m/s (at pin plunger)
Operating frequency
Mechanical: 240 operations/min
Electrical:
20 operations/min
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Contact resistance
15 m
Ω
max. (initial value)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between non-continuous terminals
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal part,
and between current-carrying metal part and ground and between switches
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction: 1,000 m/s
2
{approx. 100G} max.
Malfunction: 300 m/s
2
{approx. 30G} max. (See notes 1 and 2.)
Durability
Mechanical: 1,000,000 operations min.
Electrical:
500,000 operations min.
Ambient temperature
Operating:
−
25
°
C to 80
°
C (with no icing)
Ambient humidity
Operating: 35% to 85% max.
Weight
Approx. 30 to 50 g
COM1
COM2
NC1
NO1
NC2
NO2