![Omron D5A - Datasheet Download Page 7](http://html1.mh-extra.com/html/omron/d5a/d5a_datasheet_1633454007.webp)
277
D5A
D5A
Precautions
■
Correct Use
Handling of Fiber Cable
Do not pull or impose any force exceeding 29.42 N on the fiber
cable.
Make sure that the bending radius of the fiber cable is as large as
possible and at least 25 mm.
The 40-mm portion of the fiber cable on the connector end as
shown below must not be bent.
Do not impose compressing loads on the fiber cable.
The fiber cable can be cut with OMRON’s E39-F4 Cutting Tool.
Do not impose any force exceeding 29.42 N on the cord, other-
wise the cord may break. Make sure that the bending radius of
the cord is at least 20 mm.
Mounting
For the mounting dimensions, refer to the following figures and tables.
Do not tighten the nut with too much force.
Be sure to apply the clamping torque shown in this table.
When mounting the Switch to a panel, be sure to use the toothed
lock washer attache as an accessory (to M5, M8, and M16 types
only). Use the washer on the panel surface opposite the object to
be detected by the Switch.
40 mm min.
R25 mm min.
Fiber cable
Dimensions
M5
M8
M16
Contact
output
Solid-state
output
A
Mounting hole
5.2
0.1 mm dia.
8.2
0.1 mm dia.
16.2
0.1 mm dia.
B
Panel thickness
3 to 10 mm
5 to 8 mm
5 to 13 mm
10 to 17 mm
C
Toothed lock washer
10 mm dia.
15 mm dia.
26 mm dia.
Dimensions
Slim
Limit
A
Mounting pitch
12
0.2 mm
20
0.2 mm
B
Tapping
M2.6
M4
Mounting hole
B
C
A
A
B
2.8 mm dia.
+0.2
°
−
0
°
4.2 mm dia.
+0.2
°
−
0
°
Type
Clamping torque
M5
0.98 N • m max.
M8
2.94 N • m max.
M16
9.81 N • m max.
Slim
0.29 N • m max. (M2.6 screw)
Limit
1.47 N • m max. (M4 screw)
Object
to be
detected
Pa
n
el
Nut
Toothed lock washer