![Omron D5A - Datasheet Download Page 3](http://html1.mh-extra.com/html/omron/d5a/d5a_datasheet_1633454003.webp)
273
D5A
D5A
■
Characteristics
Note:
1. The above figures are initial values.
2. Contact your OMRON sales representative for measurement conditions of the repeat accuracy.
3. Life expectancy values are calculated at an operating temperature of 5
C to 35
C, and an operating humidity of 40% to 70%.
Contact your OMRON sales representative for more detailed information on other operating environments.
4. The value indicates the operating position change rate for a change of 1
C in the ambient temperature.
■
Operating Characteristics
Note:
1. The operating position of these types is the same as the free position because of high sensitivity (repeat accuracy: 1
m
m max.).
2. Total movement is 1.9 to 2.1 mm. Set the appropriate stroke (plunging depth) to 1.0 to 1.5 mm from the FP.
Degree of protection
D5A-1
#
, D5A-2
#
: IP40
Other than the above models: IP67
Repeat accuracy (see note 2)
M5 (D5A-1
###
series), M8, slim type:1
m
m max.
M5 (D5A-2
###
series), M16, limit type:3
m
m max.
Life expectancy (see note 3)
Mechanical: 10,000,000 operations min.
Malfunction: 1,000,000 operations min. (under rated load)
Deviation in electrical life expectan-
cy after 1,000,000 operations
M5, M8, M16, slim type:
10
m
m max.
Limit type:
20
m
m max.
Operating speed
1
m
m to 0.5 m/s
Rated frequency
50/60 Hz
Insulation resistance
100 M
W
min. (at 250 VDC) between each terminal and ground
Contact resistance
800 m
W
max. (initial) with 1 m cable,
2.4
W
max. (initial) with 3 m cable, 4
W
max. (initial) with 5 m cable)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between each terminal and ground
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Mechanical: 1,000 m/s
2
min.
Malfunction: 300 m/s
2
min.
Temperature coefficient
(see note 4)
M5, M8, slim type:
20 x 10
–6
/
C max.
M16 type:
40 x 10
–6
/
C max.
Limit type:
50 x 10
–6
/
C max.
Ambient temperature
Operating: –20
C to 75
C (with no icing)
Ambient humidity
Operating: 30% to 85% (30% to 95% with the seal rubber)
Model
D5A-1100
D5A-2100
(see note 2)
D5A-1200
D5A-2200
(see note 2)
D5A-3200
D5A-3210
(see note 2)
D5A-3300
D5A-3310
(see note 2)
D5A-5210
(see note 2)
D5A-5310
(see note 2)
OF max.
0.29 N
0.49 N
0.49 N
0.98 N
0.49 N
0.98 N
OT min.
1.5 mm
1.5 mm
1.5 mm
1.5 mm
1.5 mm
1.5 mm
MD max.
5
m
m
5
m
m
5
m
m
5
m
m
5
m
m
5
m
m
OP
(see note 1)
(2 mm)
(2 mm)
(6.5 mm)
(6.5 mm)
10.5
0.4 mm
10.5
0.4 mm
Model
D5A-7400/-7410
D5A-7403/-7413
D5A-8511/-8514
D5A-8512/-8515
D5A-9511/-9514
D5A-9512/-9515
OF max.
2.45 N
3.93 N
PT max.
1 mm
1 mm
OT min.
2 mm
5 mm
4 mm
MD max.
5
m
m
5
m
m
5
m
m
OP
(4.4 mm)
21.0
0.4 mm
15.2
0.4 mm
FP
(5 mm)
(21.8 mm)
(15.8 mm)