G-134
Safety Sensors / Components
Characteristics
Note: 1.
The above values are initial values.
2.
Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity. Doing so may result in rough-
ening of the contact surface and contact reliability may be lost.
3.
The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are suffi-
cient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do
not use the D4NS in places where foreign material may penetrate through the key hole on the head, otherwise Switch damage or mal-
functioning may occur.
4.
The durability is for an ambient temperature of 5
°
C to 35
°
C and an ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
5.
If the ambient temperature is greater than 35
°
C, do not pass the 3-A, 250-VAC load through more than 2 circuits.
6.
These figures are minimum requirements for safe operation.
7.
This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the ac-
tual load beforehand.
Degree of protection (See note 3.)
IP67 (EN60947-5-1)
(This applies for the Switch only. The degree of protection for the key hole is IP00.)
Durability
(See note 4.)
Mechanical
1,000,000 operations min.
Electrical
500,000 operations min. for a resistive load of 3 A at 250 VAC (See note 5.)
300,000 operations min. for a resistive load of 10 A at 250 VAC
Operating speed
0.05 to 0.5 m/s
Operating frequency
30 operations/minute max.
Direct opening force (See note 6.)
60 N min.
Direct opening travel (See note 6.)
10 mm min.
Contact resistance
25 m
Ω
max.
Minimum applicable load (See note 7.)
Resistive load of 1 mA at 5 VDC (N-level reference value)
Rated insulation voltage (U
i
)
300 V
Protection against electric shock
Class II (double insulation)
Pollution degree (operating environment)
3 (EN60947-5-1)
Impulse withstand voltage (EN60947-5-1)
Between terminals of the same polarity
2.5 kV
Between terminals of different polarities
4 kV
Between other terminals and uncharged metallic parts
6 kV
Insulation resistance
100 M
Ω
min.
Contact gap
2 x 2 mm min
Vibration resistance
Malfunction
10 to 55 Hz, 0.75-mm single amplitude
Shock resistance
Destruction
1,000 m/s
2
min.
Malfunction
300 m/s
2
min.
Conditional short-circuit current
100 A (EN60947-5-1)
Rated open thermal current (I
th
)
10 A (EN60947-5-1)
Ambient temperature
Operating: -30
°
C to 70
°
C with no icing
Ambient humidity
Operating: 95% max.
Weight
Approx. 96 g (D4NS-1CF)
F502-EN2-04.book Seite 134 Dienstag, 26. Juli 2005 5:48 17