background image

4

Miniature Limit Switch 

D4CC

Characteristics

Note: 1. The above figures are initial values.

2. The values are calculated at an operating temperature of 5

°

C to 35

°

C, and an operating humidity of 40% to 70%. Contact your OMRON

sales representative for more detailed information on other operating environments.

3. Excluding plastic rod models.

Leakage Current (for Switches with Indicators)

The leakage current and resistance of Switches with indicators are as follows:

Operating Characteristics

Degree of protection

IP67

Durability (see note 2)

Mechanical: 10,000,000 operations min.
Electrical:

200,000 operations min. (1 A at 125 VAC, resistive load)

Operating speed

Plunger:

0.1 mm to 0.5 m/s

Roller lever: 1 mm to 1 m/s

Operating frequency

Mechanical: 120 operations/min
Electrical:

30 operations/min

Rated frequency

50/60 Hz

Insulation resistance

100 M

 min. (at 500 VDC)

Contact resistance (initial)

100 m

 max.

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each 
terminal and non-current-carrying metal part

Vibration resistance

Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 3)

Shock resistance

Destruction: 1,000 m/s

2

 min.

Malfunction: 500 m/s

2

 min.

Ambient temperature

Operating: –10

°

C to 70

°

C (with no icing)

Ambient humidity

Operating: 95% max.

Weight

Approx. 120 g (in the case of D4CC-1002)

Item

D4CC-2

@@@

D4CC-4

@@@

Voltage

125 VAC

30 VDC

Leakage current

1.0 mA

1.0 mA

Resistive value

150 k

30 k

Model

D4CC-

@

001

D4CC-

@

002

D4CC-

@

003

D4CC-

@

010

D4CC-

@

024

OF max.

11.77 N

11.77 N

11.77 N

11.77 N

5.69 N

RF min.

4.41 N

4.41 N

4.41 N

4.41 N

1.47 N

PT max.

1.8 mm

1.8 mm

1.8 mm

1.8 mm

10

±

3

°

OT min.

3 mm

3 mm

3 mm

3 mm

50

°

MD max.

0.2 mm

0.2 mm

0.2 mm

0.2 mm

3

°

OP

15.7

±

1 mm

28.5

±

1 mm

28.5

±

1 mm

28.5

±

1 mm

---

Model

D4CC-

@

031

D4CC-

@

032

D4CC-

@

033

D4CC-

@

041

D4CC-

@

042

D4CC-

@

043

OF max.

17.65 N

17.65 N

17.65 N

11.77 N

11.77 N

11.77 N

RF min.

4.41 N

4.41 N

4.41 N

4.41 N

4.41 N

4.41 N

PT max.

1.8 mm

1.8 mm

1.8 mm

1.8 mm

1.8 mm

1.8 mm

OT min.

3 mm

3 mm

3 mm

3 mm

3 mm

3 mm

MD max.

0.2 mm

0.2 mm

0.2 mm

0.2 mm

0.2 mm

0.2 mm

OP

24.9

±

1 mm

34.3

±

1 mm

34.3

±

1 mm

31.2

±

1 mm

36.8

±

1 mm

36.8

±

1 mm

TT 
(reference value)

(5) mm

(5) mm

(5) mm

(5) mm

(5) mm

(5) mm

Model

D4CC-

@

050

D4CC-

@

060

OF max.

1.47 N

6.67 N

RF min.

---

1.47 N

PT max.

15

°

10

±

3

°

OT min.

---

50

°

MD max.

---

3

°

Summary of Contents for D4CC -

Page 1: ...Legend 1 Rated Load These codes are different from suffix codes of the D4C 1 1 A at 125 VAC 2 1 A at 125 VAC with LED indicator 3 1 A at 30 VDC 4 1 A at 30 VDC with LED indicator 2 Actuator 01 Pin pl...

Page 2: ...3024 D4CC 4024 D4CC 1031 D4CC 2031 D4CC 3031 D4CC 4031 D4CC 1032 D4CC 2032 D4CC 3032 D4CC 4032 D4CC 1033 D4CC 3033 D4CC 4033 D4CC 1041 D4CC 2041 D4CC 3041 D4CC 4041 D4CC 1042 D4CC 2042 D4CC 3042 D4CC...

Page 3: ...f 0 4 min AC and a time constant of 7 ms max DC 3 Lamp loads have an inrush current of 10 times the steady state current 4 Motor loads have an inrush current of 6 times the steady state current D4CC 3...

Page 4: ...nd and between each terminal and non current carrying metal part Vibration resistance Malfunction 10 to 55 Hz 1 5 mm double amplitude see note 3 Shock resistance Destruction 1 000 m s2 min Malfunction...

Page 5: ...he free position the indicator is lit and when the actuator is turned or pushed and the contact comes into contact with the NO side the indicator turns OFF Plugs NC COM E NO NO COM NC E 2 3 1 4 NO COM...

Page 6: ...ller Center lever Built in switch Ground terminal Molded resin O ring NBR Nitrile rubber diaphragm Open space to reduce a change in internal pneumatic pressure and to prevent the res piratory movement...

Page 7: ...ax 57 max 40 max Indicator 50 max 65 max 10 dia stainless steel plunger Indicator 40 max 59 5 max 75 max 12 dia x 5 stainless steel roller 40 max 16 Indicator 75 max 59 5 max 40 max 12 dia x 5 stainle...

Page 8: ...x 5 stainless steel roller Rubber seal Indicator 57 max 40 max 12 dia x 5 stainless steel roller Rubber seal Indicator 40 max 57 max Sealed Roller Plunger D4CC 032 Sealed Crossroller Plunger D4CC 033...

Page 9: ...0 7 max Indicator Center Roller Lever D4CC 60 17 5 dia x 7 stainless steel roller 0 Two 5 1 0 2 dia holes counter sunk 10 2 dia depth 6 1 m 2 m 5 m 10 m Model Cable length L XS2F D421 C A XS2F D421 D...

Page 10: ...2 30 0 2 58 7 0 2 25 0 2 5 1 0 2 11 dia D4C P002 For D4CC 002 D4C P020 For D4CC 024 44 OP of WLD2 Two M5 x 0 8 tapped hole See note 3 Note 1 Four hexagonal flat head bolts M5 x 0 8 length 10 and two A...

Page 11: ...ection re tight en to the torque specified above Be careful not to allow any for eign substance to enter the Switch Plug Tightening Connect the plug connector B to the connector threads of the D4CC Th...

Page 12: ...r roller lever along with the dog or cam so that the concave part A of the head is located between the convex parts of the head as shown below when the center roller lever is pressed by the dog or cam...

Reviews: