background image

G-143

D4BS

D4B

S

Safety-door Switch

D4BS

Safety-door Switch’s Special 
Operation Key Directly Pulls 
Apart the Contacts from Each 
Other and Contributes to the 
Safety of the Production Site

• Conforms to EN (TÜV) standards cor-

responding to the CE marking.

• Approved by UL, CSA, BIA, and SUVA 

standards.

• The switch contact is opened by a di-

rect opening mechanism (NC contacts 
only) when the protective cover is 
opened. The EN-approved direct open-
ing mechanism is indicated by 

 on 

the Switch.

• Degree of protection of the switch box: 

IP67 (EN60947-5-1).

• Series includes models with gold-plat-

ed contacts for handling the micro-load 
range.

• Metric conduit types available.

Model Number Structure

Model Number Legend

Ordering Information

List of Models

Switches

 Prefered stock item

Type

Mounting direction

Conduit size

1NC/1NO 

(Slow-action)

2NC (Slow-action)

1-conduit

Front-side 
mounting

Pg13.5

D4BS-15FS

D4BS-1AFS

G1/2

D4BS-25FS

D4BS-2AFS

M20

D4BS-45FS

D4BS-4AFS

3-conduit

Pg13.5

D4BS-55FS

D4BS-5AFS

G1/2

D4BS-65FS

D4BS-6AFS

M20

D4BS-85FS

D4BS-8AFS

1

2

3

1

D4BS -               S

1. Conduit

D4BS - K

Switch

Operation Key

1. Operation Key Type

2. Built-in Switch

3. Head Mounting Direction

1: PG13.5 (1 conduit)
2: G1/2 (1 conduit)
3: 1/2-14NPT (1 conduit)
4: M20
5: PG13.5 (3-conduit)
6: G1/2 (3-conduit)
7: 1/2-14NPT (3-conduit)
8: M20 (3-conduit)

5: 1NC/1NO (slow-action)
6: 1NC/NO (slow-action), gold-plated contacts
A: 2NC (slow-action)
B: 2NC (slow-action), gold-plated contacts

F:  Four mounting directions pos-

sible (front-side mounting at 
shipping)

1: Horizontal mounting
2: Vertical mounting
3: Adjustable mounting (Horizontal)

F502-EN2-04.book  Seite 143  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for D4BS -

Page 1: ...odel Number Legend Ordering Information List of Models Switches Prefered stock item Type Mounting direction Conduit size 1NC 1NO Slow action 2NC Slow action 1 conduit Front side mounting Pg13 5 D4BS 1...

Page 2: ...e UL CSA UL508 CSA C22 2 No 14 A600 Type Model D4BS K1 D4BS K2 D4BS K3 Horizontal mounting Vertical mounting Adjustable mounting Horizontal Agency Standard File No T V Rheinland EN60947 5 1 UL UL508 E...

Page 3: ...and ground and between each ter minal and non current carrying metal part Contact resistance 25 m max initial value Rated insulation voltage Ui 600 V EN60947 5 1 Conventional enclosed thermal current...

Page 4: ...contacts from each other by using shearing force if any abnormality such as contact welding should occur in the contact area There is a difference in level between the NC and NO terminal which assures...

Page 5: ...amping screws Six 5 3 dia mounting holes Four M3 5 x 10 cover clamping screws D4BS 1 S Pg13 5 D4BS 2 S G1 2 D4BS 4 S 1 2 14NPT D4BS 5 S 3 Pg13 5 D4BS 6 S 3 G1 2 D4BS 8 S 3 1 2 14NPT 30 0 2 19 61 N max...

Page 6: ...Key insertion radius in horizontal direction R 1200 53 5 min 58 max Operation Key insertion radius in horizontal direction R 1000 D4BS 1 S D4BS K2 D4BS 2 S D4BS K2 D4BS 4 S D4BS K2 54 5 min 59 max Ope...

Page 7: ...on Locations where the product may come into direct contact with pro cessing waste or dust Operation Key Be sure to use a special Operation Key only Do not operate the D4BS with anything other than th...

Page 8: ...d Mounting Direction By removing the screws on the four corners of the head the head can be reset in any of four directions The head direction can be changed with or without the Operation Key inserted...

Page 9: ...ing so that the enclosure will confirm to IP67 If using a Pg13 5 conduit use an ABS 08 Pg13 5 connector or an ABS 12 Pg13 5 connector manufactured by Nippon Flex Use a connector SC Series sold separat...

Page 10: ...est of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounc...

Reviews: