Wiring

Applicable Wires

The wires that you can connect to the terminal block are twisted wires, solid wires, and ferrules that are attached to the twisted wires. The following 
section describes the dimensions and processing methods for applicable wires.

Using Ferrules

If you use ferrules, attach the twisted wires to them.
Observe the application instructions for your ferrules for the wire stripping length when attaching ferrules.
Always use plated one-pin ferrules. Do not use unplated ferrules or two-pin ferrules.

The applicable ferrules, wires, and crimping tools are listed in the following table.

Using Twisted or Solid Wires

Required Tools

Use a flat-blade screwdriver to remove wires.
The recommended screwdriver is as follows.

Dimensions

 (Unit: mm)

Digital I/O Unit

Manufacturer

Ferrule model

Applicable wire

(mm

2

 (AWG))

Crimping Tool

 (applicable wire size given in parentheses)

Phoenix Contact

AI0,5-10

0.5 (#20)

Phoenix Contact
CRIMPFOX 6 (0.25 to 6 mm

2

, AWG24 to 10)

AI0,75-10

0.75 (#18)

AI1,0-10

1.0 (#18)

AI1,5-10

1.5 (#16)

Weidmüller

H0.5/16

0.5 (#20)

Weidmüller
PZ6 Roto (0.14 to 6 mm

2

, AWG26 to 10)

H0.75/16

0.75 (#18)

H1.0/16

1.0 (#18)

H1.5/16

1.5 (#16)

Wire type

Conductor cross-sectional area

Conductor length

(stripping length)

Solid wire

0.14 to 1.5 mm

2

10 mm

Twisted wire

Model

Manufacturer

SZF 0-0,4X2,5

Phoenix Contact

31.6

90

80

Summary of Contents for CK3W-MD71 0 Series

Page 1: ...odels PNP and NPN CK3W MD71 0 EtherCAT is a registered trademark and patented technology licensed by Beckhoff Automation GmbH Germany Other company names and product names in this document are the tra...

Page 2: ...pply Unit Unless the Expansion Master Unit CK3W EXM01 is connected adjacent to the right side of the CPU Unit the Sys Status register CK3WConfigErr becomes 5 Letter Configuration Remarks A Power Suppl...

Page 3: ...D Unit Analog Input Unit You can add 4 or 8 voltage inputs G End Cover Must be connected to the right end of the CPU Rack and Expansion Rack The CPU Unit and the Expansion Slave Unit are each provided...

Page 4: ...o 95 with no condensation or icing Atmosphere Must be free of corrosive gases Ambient Storage Temperature 25 to 70 C with no condensation or icing Vibration Resistance Conforms to IEC 60068 2 6 5 to 8...

Page 5: ...min OFF voltage OFF current 5 VDC max 1 mA max ON OFF response time 20 s max 400 s max Isolation method Isolation by Photocoupler between input and internal circuit Circuit configuration NPN type PNP...

Page 6: ...4 VDC Maximum load current 0 5 A point 2 A Unit Maximum inrush current 4 0 A point 10 ms max Leakage current 0 1 mA max Residual voltage 1 0 V max ON OFF response time 0 1 ms max 0 8 ms max Isolation...

Page 7: ...esidual voltage 1 0 V max ON OFF response time 0 1 ms max 0 8 ms max Isolation method Isolation by Photocoupler between output and internal circuit Load short circuit prevention Provided Circuit confi...

Page 8: ...dicator Shows the power supply status C Digital input output status indicator Shows the digital input output status D Terminal block Connects the digital input output E Unit connector Connector that c...

Page 9: ...ires and crimping tools are listed in the following table Using Twisted or Solid Wires Required Tools Use a flat blade screwdriver to remove wires The recommended screwdriver is as follows Dimensions...

Page 10: ...ogrammable Multi Axis Controller The following information is provided on the CK3M series Pro grammable Multi Axis Controller Details of commands Details of data structure Power PMAC IDE User Manual O...

Page 11: ...ERS Chicago IL USA 847 843 7900 800 556 6766 automation omron com Controllers I O Machine Automation Controllers MAC Motion Controllers Programmable Logic Controllers PLC Temperature Controllers Remot...

Reviews: