background image

CJ1W-NC

@@

4

6

Specifications

General Specifications

Models other than above conform to the general specifications of the CJ series.

Performance Specifications

* This indicates the number of occupied words of special I/O Unit area. In addition, this occupies areas that correspond to up to 144 words 

according to the number of axes and functions which you use.

Specification item

Model

CJ1W-NC214/234

CJ1W-NC414/434

Power supply voltage

5 VDC (unit)

24 VDC (external power supply)

Allowable power supply voltage range

21.6 to 26.4 VDC (external power supply)

Internal current consumption

5 VDC, 270 mA maximum

5 VDC, 310 mA maximum

Current consumption of external power supply

24 VDC
   NC214 13 mA maximum
   NC234 44 mA maximum

24 VDC
   NC414 26 mA maximum
   NC434 90 mA maximum

Dimensions

90 

×

 51 

×

 65 (H 

×

 W 

×

 D)

90 

×

 62 

×

 65 (H 

×

 W 

×

 D)

Weight

170 g maximum

220 g maximum

Ambient operating temperature

0 to 55

°

C

Mounting position

CJ-series CPU Rack or CJ-series Expansion Rack

Maximum number of units per rack

5 units

Maximum number of units per CJ system

20 units (when up to 3 expansion racks are connected)

Occupied unit

No. 2

Applicable standards

cULus, EC directives

Specification item

Model

CJ1W-NC214/234

CJ1W-NC414/434

Applicable PLCs

CJ-series

Number of occupied inputs/
outputs

Number of words

18CH *

Controlled drivers

Servo Drive of pulse train input type or stepping motor drivers
   NC214/414: Open collector output type
   NC234/434: Line driver output type

Pulse output method

Phase difference pulse output, forward/reverse direction pulse output, pulse + direction output

Controls

Control method

Open-loop control by pulse train output

Number of controlled axes

2 axes

4 axes

Units of control

Pulse, mm, inch, degree

Positioning functions

Memory operation, direct operation

Independent operation

Independent, 2 axes

Independent, 4 axes

Linear interpolation

2 axes maximum

4 axes maximum

Circular interpolation

2 axes maximum

2 axes maximum

Speed control

Independent, 2 axes

Independent, 4 axes

Interrupt Constant-pitch Feed

Independent, 2 axes

Independent, 4 axes

Position command

Data

2147483648 to +2147483647

Number of data

500 per task (4 tasks per unit)

Speed command

Data

Position control: 1 to 2147483647
Speed control: 

2147483648 to 2147483647

However, this limits the maximum output frequency based on whether the maximum speed is 4 
Mpps (NC234/434) or 500 kpps (NC214/414).

Number of data

500 per task

Acceleration/deceleration 
time

Data

0 to 250000 ms

Number of data

500 per task

Function

Override

0.01% to 500.00% (settable for each axis)

Software limits

2147483647 to 2147483646 command unit

(Settable for each axis)

Backlash Compensation

0 to 50000 command unit (settable for each axis)

MPG and external encoder 
counter input

Number of input words

1 word (switchable for each controlled axis)

Input interface

Photocoupler input

Maximum response 
frequency

500 kHz

Feedback pulse counter 
input

Number of input words

4 words (1 word per axis)

Input interface

Line receiver input

Maximum response 
frequency

NC234/434: 4 MHz (phase difference multiplication of 4 times: 1 MHz)
NC214/414: 500 kHz (phase difference multiplication of 4 times: 125 kHz)

Summary of Contents for CJ1W-NC214 -

Page 1: ...d G5 series Servomotors are supported enabling an absolute positioning system This eliminates the need to redefine the origin after power interruptions helping to provide extra added value Select from direct operation or memory operation Up to 500 positioning sequences can be saved as the data for memory operation for each axis Any of three end patterns independent automatic or consecutive can be ...

Page 2: ... CJ1 Special I O Units Position Control Units High Speed type Pulse train open collector output with Pulse Counter Function 2 axes 2 0 27 CJ1W NC214 UC1 CE 4 axes 0 31 CJ1W NC414 Pulse train line driver output with Pulse Counter Function 2 axes 2 0 27 CJ1W NC234 4 axes 0 31 CJ1W NC434 Product name Specifications Model Standards Number of licenses Media FA Integrated Tool Package CX One Ver 4 The C...

Page 3: ... G16 3m XW2Z 300J G16 OMNUC G G5 Series R88D GT KT 2 axes 1m XW2Z 100J G5 3m XW2Z 300J G5 SMARTSTEP2 R7D BP 1m XW2Z 100J G8 3m XW2Z 300J G8 Line driver output CJ1W NC 34 OMNUC G G5 Series R88D GT KT 1 axis 1m XW2Z 100J G9 5m XW2Z 500J G9 10m XW2Z 10MJ G9 SMARTSTEP2 R7D BP 1m XW2Z 100J G12 5m XW2Z 500J G12 10m XW2Z 10MJ G12 OMNUC G G5 Series R88D GT KT 2 axes 1m XW2Z 100J G1 5m XW2Z 500J G1 10m XW2...

Page 4: ...Z 200X Cable length 3 0m XW2Z 300X Cable length 5 0m XW2Z 500X Cable length 10 0m XW2Z 010X Connector Terminal Block 20 points M2 4 screw terminal XW2B 20G4 20 points M3 5 screw terminal XW2B 20G5 20 points M3 screw terminal XW2D 20G6 Name Specifications Model Connector Socket For a 50 pin MIL plug crimp socket connector For AWG24 XG5M 5032 N Connector Cover For a 50 pin MIL plug crimp socket conn...

Page 5: ...14 234 414 434 Not supported 5 Units 5 Units per Expansion Backplane Not Supported Not Supported 5 Units CPU Unit Functions Required Programming Device CX Programmer Programming Console Ver 7 1 or lower Ver 8 0 Ver 8 02 or higher CJ1W NC 4 Unit Ver 1 0 Functions for unit version 1 0 Not supported Not supported Supported Not supported 1 Move Absolute 14 Manual Pulses Output 2 Unlimited Move Absolut...

Page 6: ...Phase difference pulse output forward reverse direction pulse output pulse direction output Controls Control method Open loop control by pulse train output Number of controlled axes 2 axes 4 axes Units of control Pulse mm inch degree Positioning functions Memory operation direct operation Independent operation Independent 2 axes Independent 4 axes Linear interpolation 2 axes maximum 4 axes maximum...

Page 7: ...onstant speed Inching operation The axis inches in the forward reverse direction MPG operation Connect a manual pulsar and perform manual feed Auxiliary control function Command unit setting You can set a desired unit of control for each axis according to the machine Acceleration deceleration control Auto acceleration deceleration control This function automatically generates an acceleration decel...

Page 8: ...Lit ON Phase A B input status of the Axis 1 feedback counter ON when lit OFF when unlit Unlit OFF A2 B2 Orange Lit ON Phase A B input status of the Axis 2 feedback counter ON when lit OFF when unlit Unlit OFF A3 B3 Orange Lit ON Phase A B input status of the Axis 3 feedback counter ON when lit OFF when unlit Unlit OFF A4 B4 Orange Lit ON Phase A B input status of the Axis 4 feedback counter ON whe...

Page 9: ...007 Configuration Diagram for IDC Connector for Discrete Wires Connector type Model Flat cable connector XG4M 5030 T 1 IDC connector for discrete wires Socket XG5M 5032 N 2 XG5M 5035 N 3 Hood cover XG5S 5022 horizontal Socket Wires IDC tool Connection complete Hood cover Usage type Double rows with polarity guide locking possible Discrete wires Double rows Simple IDC tool XY2B 7006 Horizontal type...

Page 10: ...its Operation Manual Provides information on operating and installing Position Control Units including details on basic settings memory operation direct operation from CPU and other functions W446 SBCA 337 CXONE AL C V AL D V CX Programmer Operation Manual Describes operating procedures for the CX Programmer Also refer to the Software User s Manual W473 and Instructions Reference Manual W474 when ...

Page 11: ... products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment ...

Reviews: