background image

1

 

PNSPO!

Model 

CJ1W-CTS21-E 

Synchronous Serial Interface (SSI) Unit 

 

 

INSTRUCTION SHEET 

(NJ-series Controllers) 

 

 

Thank  you  for  purchasing  an  OMRON  product.  Read  this 
instruction  sheet  thoroughly  and  familiarise  yourself  with  the 
functions  and  characteristics  of  the  product  before  using  it.  To 
ensure safe and correct use of this Unit, also read the Operation 
and Programming Manuals for your NJ-series Controller system. 

 

Keep this instruction sheet for future reference. 

OMRON MANUFACTURING OF THE NETHERLANDS B.V. 

 OMRON Corporation 2012 

All Rights Reserved            

 

 
 

!  DANGER 

Do  not  attempt  to  take  the  Unit  apart  and  do  not 
touch  any  internal  parts  while  the  power  is  being 
supplied.  Doing  either  of  these  may  result  in 
electrical shock, and serious or fatal injury. 
 

!  Caution 

Leave the protective label on top of the Unit as long 
as the Unit is not mounted and wired completely, in 
order  to  prevent  wire  clippings  or  other  materials 
from  getting  inside  the  Unit.  When  the  mounting 
and  wiring  has  been  completed,  the  label  must  be 
removed to allow air circulation and heat radiation. 

 

 

Nomenclature 

 

Unit status LED indicators 

 

RUN 

(green)  

 

ERC 

(red) 

 

ERH 

(red)  

 

CH1, CH2  (green) 

 
Machine number rotary switches 
 
Removable Terminal Block 

  Connections for SSI-encoders 

  Connection for power supply SSI-encoders 

  
Terminal Block latch 

 

Slide down to remove 

 

Slide up to lock 

 
 
 

 

Quick Start 

1. 

Set  all  configuration  device  variables  to  0.  The  Unit  is  now 
configured  as  follows:  400kHz  clock  frequency,  24  bit  Gray-
coded and a 40

µ

s monoflop time, for both SSI channels. 

2. 

Set Machine Number. 

3. 

Mount  and  wire  the  Unit,  the  two  SSI  encoders  and  the 
encoders power supply. 

4. 

Turn power on. 

5. 

Create I/O Table. 

6. 

Both green CH1 and CH2 indicators should now turn on. 

7. 

The  encoder  data  can  now  be  read  from  operational  device 
variables *_Ch1_SSIDat and *_Ch2_SSIDat. 

 
Note:
  If  you  only  want  to  connect  one  SSI  encoder,  the  other  SSI 
channel  has  to  be  disabled.  See  section  Configuration  Device 
Variables for CJ-series Units 
for further details. 

 
 
 
 
 
 

 

Unit specifications 

Unit type 

CJ1 Special I/O Unit 

Applicable PLC models 

CJ/NJ-series PLCs 

Storage temperature 

-20 to +75 °C 

Ambient temperature 

0 to +55 °C 

Ambient humidity 

10 to 90 % (non-condensing) 

EMC compliance 

EN 50081-2, EN 61131-2 

Current consumption 

300 mA (5VDC via bus connection) 

Weight 

200 g (typical) 

Number 

of 

words 

allocated 

 

20 Operation Words 

 

30 Configuration Words 

 
 

 

Dimensions 

EXT.PS FOR ENCODERS: 5-24 V DC, 0.8 A max.

CTS21

10

0

x

10

x

1

RUN
CH1
CH2

ERC

ERH

B1

A1

MACH

MACH

MACH

MACH

No

No

No

No

CJ1W-CTS21-E

SSI DATA+CLK:RS-422 Line Driver, 1.5 MHz max.

2-CHANNEL SSI UNIT

PNSPO

OMRON MANUFACTURING OF THE NETHERLANDS B.V.
MADE IN THE NETHERLANDS

Lot No. 000000N0000

Batch No. 000000000

31

65

24

90

95

 
 

 

LED Indicators 

Name 

Color 

State 

Unit status 

RUN 

green 

On 

Normal operation 

 

 

Off 

Initialisation error 

ERC 

red 

On 

Unit error  
(check *_ErrCode1/*_ErrCode2

 

 

Off 

Unit has no errors 

ERH 

red 

On 

NJ CPU Unit error 

 

 

Off 

NJ CPU Unit has no errors 

 

Name 

Color 

State 

Counter channel status  

CH1, 
CH2 

green 

On 

Channel configured and is 
communicating without errors 

 

 

Off 

Channel is not configured or a 
communication error has occurred 

 

 

 

Machine Number Switch 

Name 

Function 

MACHINE No. 

 

 

Sets the Machine Number (00 – 94).  

 

Setting  Machine  Numbers  95-99 

will generate an error. 

 

Make sure each Machine Number 

is used only once per NJ CPU. 

 

The next higher Machine Number 

should  not  be  used  on  any  unit,  as  it 
would cause a CIO-data overlap 

 

Be  sure  to  turn  off  the  power  to 

the  Unit  before  setting  the  Machine 
Number. 

 

 

x10

x10

1

0