background image

Delay OFF Rocker Switch

   

A8GS-T

5

Precautions

 !WARNING

Do not wire the switch or touch any terminal of the
Switch while power is being supplied. Or it may result
in electric shock.

 !CAUTION

Use the switch within the rated voltage and current ranges, other-
wise the switch may have deteriorated durability radiate heat, or
burn out. This particularly applies to the instantaneous voltages
and currents when switching.

Correct Use

Mounting

Easy to mount by snap fitting.

Do not impose excessive force on switch at the time of panel mounting.

Do not detach the switch after installed. Otherwise, the holding strength may
be loose.

Apply the force to housing when installing to panel. Do not apply the force to
the button (rocker) part when installing to the panel.

Wiring

Confirm the size of the receptacles and be sure to connect them firmly.

Use an appropriate wire allowable to carry current.

Be sure that there is no mechanical stress on terminals and coil terminals.Oth-
erwise, the switch may malfunction and/or damaged.
(Example: Too strong wiring)

Take appropriate insulation distance between switch terminal and other metal
parts after wiring.

Coil has polarity, please confirm polarity when wiring.

Do not apply continuous voltage more than 10 seconds at any time. Otherwise,
insulation deterioration may occur by heat of coil. Please consider the circuit
design.

Reverse voltage may cause of accurate discrete semiconductor devices. In
case of controlling by accurate discrete semiconductor devices, Please con-
sider the circuit design. (Example : add the surge absorbing circuit)

In case of manual soldering, soldering time is max 4 sec by soldering iron 
(Max 350 

°

C at the iron tip) and do not add the stress to terminals.

In case of touching the soldering iron to the root of terminals, it may cause
Housing parts melt.

Handling

Do not apply excessive operating force to the switch.

Do not drop or apply the excessive shock. 
Otherwise the switch may be damaged or deformed.

Do not impose force to operating part from an angle, Otherwise the switch may
be damaged or deformed.

Environment for storage and use

To prevent the terminals color change and others while storage, Do not keep
for a long term in the following conditions.

(1) High temperature, high humid environment 
(2) Corrosive gas 
(3) The place where the direct rays of the sun 
(4) The place where the sea breeze 
(5) Environmental with a sudden temperature change

This switch is not sealed to prevent from entering dust and liquid. 
Do not use under dust and liquid condition.

Switch shall not be icing or condensation.

Strong magnetic field may cause malfunction. 
Check function is recommended under practical use conditions.

Using Micro Loads

In case of using the switch under the micro loads, please refer the Minimum
applicable load and set the load more than minimum applicable load.

Even when using micro load within the operating range, if inrush current
occurs, it may increase contact wear and so deteriorate durability.Therefore,
insert a contact protection circuit where necessary.

The minimum applicable load is the L-level reference value.

This value indicates the malfunction reference level for the reliability level of 
60 %. (

λ 

60)

The equation, 

λ

 60 = 0.5 x 10

-6

 /operations indicates that the estimated mal-

function rate is less than 1/2,000,000 operations with a reliability level of 60 %.

RoHS Compliant

The "RoHS Compliant" designation indicates that the listed models do not con-
tain the six hazardous substances covered by the RoHS Directive.

Reference: The following standards are used to determine compliance for the
six substances.

Lead

 1,000 ppm max.

Mercury

 1,000 ppm max.

Cadmium : 

 100 ppm max.

Hexavalent chromium:   1,000 ppm max.

PBB

 1,000 ppm max.

PBDE

 1,000 ppm max.

Usage Example

Saving energy by cutting standby power.
Saving energy by preventing forgetting turn OFF main power.
Turning OFF main power by remote.
Turning OFF main power of many equipments at the same time.
Timing control of main power switch turn OFF for safety design.
Preventing from circuit and data damage by power flicker.

Pushing position

Correct

Incorrect

Reviews: