Safety Precautions

Refer to 

Safety Precautions for All Pushbutton Switches

.

Do not apply a voltage higher than the maximum 
rated operating voltage between the lamp terminals, 
as there is a risk that the incandescent lamp or LED 
lamp will be damaged, and the Pushbutton will be 
ejected.

When replacing the incandescent lamp, first turn OFF 
the power supply, and then wait 10 minutes before 
performing replacement, as the lamp is still hot 
immediately after the power is turned OFF, so there 
is a risk of burns.

Mounting

To prevent electric shock or a fire, always make sure that the power 
is turned OFF before mounting, removing, or wiring the Switch, or 
performing maintenance.

Do not tighten the mounting ring excessively using pliers or a similar 
tool. Excessive tightening may damage the mounting ring. 
(Tightening torque: 0.20 to 0.39 N·m {20 gf to 40 gf})

Wiring

When wiring, use wires of a size appropriate for the applied voltage 
and carry current. Perform soldering correctly under the conditions 
given below. Using the Switch with the wires soldered incorrectly 
may cause the terminals to become abnormally hot and cause a 
fire.

1. Soldering iron tip temperature: 350

°

C max. within 3 seconds.

2. Dip soldering: At 350

°

C within 3 seconds.

Wait for one minute after soldering before exerting any external 
force on the solder.

Use a non-corrosive rosin liquid for the flux.

Perform wiring so that the wire sheaths do not come into contact 
with the Switch. If this is unavoidable, use wires that can withstand 
temperatures of 100

°

C min.

After wiring to the Switch has been completed, ensure an 
appropriate insulation distance.

Operating Environment

Do not use in locations that are subject to dust, oil, or metal filings 
as these may penetrate the interior of the Switch and cause 
malfunction.

Using Microloads

Using a standard load switch for opening and closing a microload 
circuit may cause wear on the contacts. Use the switch within the 
operating range. (Refer to the diagram below.) Even when using 
microload models within the operating range shown below, if inrush 
current occurs when the contact is opened or closed, it may cause 
the contact surface to become rough, and so decrease life 
expectancy. Therefore, insert a contact protection circuit where 
necessary. The minimum applicable load is the N-level reference 
value. This value indicates the malfunction reference level for the 
reliability level of 60% (

λ

 60) (conforming to JIS C5003). The 

equation, 

λ

 60 = 0.5 x 10

6

/times indicates that the estimated 

malfunction rate is less than 1/2,000,000 with a reliability level of 
60%.

LED

Resistance to limit the LED current is provided internally and so an 
external resistance is not required.

CAUTION

Precautions for Correct Use

Rated voltage

Internal limiting resistance

5 VDC

33 

Ω

12 VDC

270 

Ω

24 VDC

1,600 

Ω

Microload
area

Standard
load area

Invalid
area

0.1

1

10

100

1,000

100mA 150mA

1mA

5

12

24

30

0.15mA

26mA

100mA

Current (mA)

0

V

oltage (V)

Summary of Contents for A3C Series

Page 1: ...aking Miniature size with excellent feeling of operation RoHS Compliant Refer to Safety Precautions for All Pushbutton Switches and Safety Precautions on page 12 List of Models Appearance Model Rectan...

Page 2: ...dard Load Microload Standard Load 0 5 A at 250 VAC 1 A at 125 VAC 1 A at 30 VDC Microload 0 1 A at 125 VAC 0 1 A at 30 VDC Minimum applicable load 1 mA at 5 VDC Momentary action Self resetting Alterna...

Page 3: ...A3CJ 90E1 24E Incandescent lamp A3CJ 90A1 06 R red Y yellow G green W white A blue B black A3CJ 90A1 14 A3CJ 90A1 28 A3CJ 90B1 28 Non lighted A3CJ 90A0 A3CJ 90B0 A3CJ 90E0 Square A3CA LED lamp A3CA 90...

Page 4: ...tion models order the Pushbutton Lamp and Switch as shown in the following table Illuminated color Pushbutton Lamp LED Switch Red IP40 A3C 500W Enter one of the following sym bols in J Rectangular A S...

Page 5: ...ng individual Units Also store the parts as spares for maintenance and repairs Ordering Specify a model number from the following page LED Lamp Operation Unit Lamps LED Lamp Incandescent Lamp Switch N...

Page 6: ...500G A3CA 500G A3CT 500G White A3CJ 500W A3CA 500W A3CT 500W Blue A3CJ 500A A3CA 500A A3CT 500A Shape Button color Rectangular Square Round Red A3CJ 500R A3CA 500R A3CT 500R Yellow A3CJ 500Y A3CA 500...

Page 7: ...used with Dust Cover For square round models A3CA 5050 Dust Cover For rectangular models A3CJ 5060 Cannot be used with Switch Guard Can be used with Dust Cover attached Name Appearance Classification...

Page 8: ...Rated current Operating voltage 6 VAC DC 60 mA 5 VAC DC 14 VAC DC 40 mA 12 VAC DC 28 VAC DC 24 mA 24 VAC DC Operat ing fre quency Mechanical Momentary action models 120 operations minute max Alternate...

Page 9: ...te Blue Non lighted Models Red Yellow Green White Blue Black 3 LED Lamp Incandescent Lamp 4 Standard load 0 5 A at 250 VAC 1 A at 125 VAC 1 A at 30 VDC Microload 0 1 A at 125 VAC 0 1 A at 30 VDC Minim...

Page 10: ...ly Note Recommended panel thickness 1 0 to 3 2 mm Note Recommended panel thickness 1 0 to 3 2 mm With Switch Guard With Dust Cover 0 6 M12 1 20 1 6 9 5 9 5 26 5 15 7 11 8 18 14 0 6 M12 1 20 9 5 9 5 6...

Page 11: ...nin phthalic acid or acrylic paint when marking the legend Insulation Cover A3C 3002 13 9 dia 16 7 33 6 15 8 1 3 55 3 55 1 7 3 55 13 9 dia 16 7 33 6 3 5 0 3 1 6 0 6 1 Six 0 8 dia 9 7 0 1 5 1 0 1 7 4 0...

Page 12: ...e flux Perform wiring so that the wire sheaths do not come into contact with the Switch If this is unavoidable use wires that can withstand temperatures of 100 C min After wiring to the Switch has bee...

Page 13: ...cap of the Pushbutton and pull Note Do not use tools such as pliers to remove the Pushbutton as this may damage the cap Panel Mounting Insert the Switch from the front of the panel Mount the mounting...

Page 14: ...unting frame Mounting nut Panel Lock protrusions Switch Mounting nut Panel Holder black Guard transparent Application examples provided in this document are for reference only In actual applications c...

Reviews: