8 Trouble Shooting
8 - 6
Wireless Pushbutton Switch User’s Manual (A265)
1
Make short the Master Unit error clear terminal to 0 V.
The voltage between the error clear terminal and 0 V must be 15 VDC or less to reset the error.
The error clear terminal and 0 V are the Push-In Plus terminals.
2
The error is reset.
The Master Unit can be restored to the factory setting by the following method.
1
Turn OFF the power supply to the Master Unit.
2
With the reset button pressed, Turn ON power to the Master Unit again.
3
The setting information is initialized and it returns to the factory setting.
Error Clear Input
8-2-3
How to Return Master Unit to Factory Setting
(Upper left part of Master Unit)
Power supply terminals
Error clear terminal