background image

A165E

Accessories (Order Separately)

Specifications

Certified Standard Ratings

UL508, CSA C22.2 No.14, CCC(GB14048.5)

Models with Separate Construction

Models with One-piece Construction

TÜV(EN60947-5-1)

Models with Separate Construction

Models with One-piece Construction

Certified Standards

* Certification for CSA C22.2 No. 14 is indicated by the 

 mark. 

Switch Ratings

Models with Separate Construction

Minimum applicable load: 5 VDC, 150 mA

Models with One-piece Construction

Minimum applicable load: 5 VDC, 1 mA

LED Ratings

(Only for Models with LEDs)

Item

Appearance

Type

Model

Precautions

Yellow Plate

Yellow, 45 dia.

A16Z-5070

Use this as an emergency stop 
nameplate.

Panel Plug

Round

A16ZT-3003

Used for covering the panel cutouts 
for future panel expansion. 
Degree of protection: IP40 
Color: Black

Tightening Tool

---

A16Z-3004

Useful for repetitive mounting. Be 
careful not to tighten excessively.

Extractor

A16Z-5080

Convenient for extracting the Switch 
and Lamp.

Rated voltage

Resistive load

125 VAC
250 VAC
30 VDC

5 A
3 A
3 A

Rated voltage

Resistive load

125 VAC
250 VAC
30 VDC

1 A
0.5 A
1 A

Rated voltage

Resistive load

250 VAC
30 VDC

3 A
3 A

Rated voltage

Resistive load

250 VAC
30 VDC

0.5 A
1 A

Certification body

Standards

File No.

UL *

UL508, 
CSA C22.2 No.14

E41515

TÜV Product Service

EN60947-5-1, 
EN60947-5-5

Inquire

CQC (CCC)

GB14048.5

2003010303070678

Rated voltage

Resistive load

125 VAC
250 VAC
30 VDC

5 A
3 A
3 A

Rated voltage

Resistive load

125 VAC
250 VAC
30 VDC

1 A
0.5 A
1 A

Rated voltage

Rated current

Operation voltage

24 VDC

10 mA

24 VDC±5%

http://www.ia.omron.com/

3

(c)Copyright OMRON Corporation 2007   All Rights Reserved. 

Summary of Contents for A165E -

Page 1: ...Separate construction 30 mm model A165E 03U One piece construction 30 mm model Be sure to read the precautions for all pushbutton switches in the Pushbutton Switches Group Catalog Cat No X032 as well...

Page 2: ...utton size Terminal Contact form Model Non lighted Yellow 30 dia Solder terminal SPST NC A165E SY 01 Gray A165E SGR 01 Yellow DPST NC A165E SY 02 Gray A165E SGR 02 Yellow 40 dia SPST NC A165E MY 01 Gr...

Page 3: ...anel cutouts for future panel expansion Degree of protection IP40 Color Black Tightening Tool A16Z 3004 Useful for repetitive mounting Be careful not to tighten excessively Extractor A16Z 5080 Conveni...

Page 4: ...hanical 100 000 operations min Electrical 100 000 operations min Degree of protection IP65 Oil resistant 2 IP65 2 IP65 Oil resistant 2 Electric shock protection class Class II PTI tracking characteris...

Page 5: ...m diameter 0 7 8 0 3 Panel cutout dimensions When applying a coating such as paint to the panel dimensions after the coating must satisfy the specified dimensions Recommended panel thickness 0 5 to 3...

Page 6: ...0 dia Switch Lighted models 40 mm diameter 16 0 2 dia 0 3 0 1 dia 0 7 8 0 3 0 Panel cutout dimensions When applying a coating such as paint to the panel dimensions after the coating must satisfy the s...

Page 7: ...e panel design and mount from the front side of the panel Panel cutout dimensions are the same as those for the Switch Tightening Tool t 1 A16Z 5070 15 6 dia 45 dia 12 12 15 8 0 1 dia Rough surface 15...

Page 8: ...ile matching the protruding part of the Lamp and the small guides on the outer surface of the casing Panel Mounting nut Lock ring Rubber packing or Yellow Plate sold separately Edge Lock Cutout Panel...

Page 9: ...65E U one piece construction allows both a standard load 125 V at 1 A 250 V at 0 5 A and a microload If a standard load is applied however the microload area cannot be used If the microload area is us...

Page 10: ...eing supplied Doing so may result in electric shock Do not apply a voltage between the incandescent lamp and the terminal that is greater than the rated voltage Doing so may damage the lamp or LED and...

Page 11: ...rms test whether correct operation is possible with the actual load before application x When switching for microloads voltage or current use a Switch with microload specifications The reliability of...

Page 12: ...ding to the characteristics of the load The capacitor suppresses the spark discharge of current when the contacts are open The resistor limits the inrush current when the contacts are closed again Con...

Page 13: ...tch it may not be able to withstand the normal operating force With continuous mounting in particular select a panel of a thickness that is easily sufficient to withstand the total operating force x P...

Page 14: ...esult in metal corrosion Perform hand soldering using the appropriate soldering iron With the exception of PCB mounting Switches when performing hand soldering hold the Switch so that the terminals po...

Page 15: ...the Switch enters the bath first Storage When the Switch is left unused or stored for long periods the ambient conditions can have a great effect on the condition of the Switch In certain environment...

Page 16: ...p systems that will ensure optimal usage Related International Standards ISO 14119 Interlocking Devices Associated with Guards Principles for Design and Selection Installing Safety Products Make sure...

Page 17: ...may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control syst...

Reviews: