General Precautions 

The  user  must  operate  the  product  according  to  the  performance 
specifications  described  in  this  instruction  sheet  and  in  the  operation 
manual of the inverter. 
Before using the product under conditions which are not described in the 
inverter  manual  or  applying  the  product  to  nuclear  control  systems, 
railroad  systems,  aviation  systems,  vehicles,  combustion  systems, 
medical  equipment,  amusement  machines,  safety  equipment,  and  other 
systems, machines, and equipment that may have a serious influence on 
lives  and  property  if  used  improperly,  consult  your  OMRON 
representative. 
Make sure that the ratings and performance characteristics of the product 
are  sufficient  for  the  systems,  machines,  and  equipment,  and  be  sure  to 
provide  the  systems,  machines,  and  equipment  with  double  safety 
mechanisms. 

 

The  MX2-A

  inverter  with  a  mounted  3G3AX-MX2-EIP-A  option 

board  is  a  general  purpose  product  combination.  It  is  a  system 
component and is used in conjunction with other items of industrial 
equipment such as PLCs. 

 

A  detailed  system  analysis  and  job  safety  analysis  should  be 
performed  by  the  system  designer  or  system  integrator  before 
including  the  inverter  option  board  combination  in  any  new  or 
existing  system.  Consult  your  OMRON  representative  for 
application specific system integration information if required. 

 

The  product  will  be  used  to  control  an  adjustable  speed  drive 
connected  to  high  voltage  sources  and  rotating  machinery  that  is 
inherently  dangerous  if  not  operated  safely.  Interlock  all  energy 
sources,  hazardous  locations,  and  guards  in  order  to  restrict  the 
exposure of personnel to hazards. The adjustable speed drive may 
start the motor without warning. Signs on the equipment installation 
must be posted to this effect. A familiarity with auto-restart settings 
is a requirement when controlling adjustable speed drives. Failure of 
external  or  ancillary  components  may  cause  intermittent  system 
operation,  i.e.,  the  system  may  start  the  motor  without  warning  or 
may  not  stop  on  command.  Improperly  designed  or  improperly 
installed  system  interlocks  and  permissives  may  render  a  motor 
unable to start or stop on command. 

 

This  Instruction  Sheet  does  not  contain  illustrations  of  the  product 
with  protective  covers  removed  from  the  MX2-A

  inverter.  Make 

sure that these protective covers are on the inverter before use.

 

 
 
 

 

Safety Precautions 

Definition of Precautionary Information 

WARNING 

Indicates  a  potentially  hazardous  situation 
which,  if  not  avoided,  could  result  in  death  or 
serious  injury.  Additionally,  there  may  be 
severe property damage. 

Caution 

Indicates  a  potentially  hazardous  situation, 
which,  if  not  avoided,  may  result  in  minor  or 
moderate injury, or property damage. 

 

■ 

Warnings and Cautions

 

 

WARNING 

Do not attempt to take an option board apart or 
touch  any  internal  parts  while  the  power  is 
being supplied. Doing so may result in electric 
shock. 

 

WARNING 

Do not touch the conductive parts such as the 
internal PCB or connector while power is being 
supplied.  Doing  so  may  result  in  electrical 
shock.

 

 

WARNING 

Do  not  attempt  to  disassemble,  repair,  or 
modify  an  option  board.  Any  attempt  to  do  so 
may  result  in  malfunction,  fire,  or  electric 
shock. 

 

WARNING 

Wiring,  maintenance  or  inspection  must  be 
performed  by  authorized  personnel.  Not  doing 
so may result in electrical shock or fire. 

 

WARNING 

Turn  OFF the  power  supply  before  performing 
wiring, maintenance or inspection. Wait for the 
time  specified  on  the  Inverter  front  cover  for 
the capacitors to discharge. Not doing so may 
result in electrical shock. 

 

WARNING 

Provide  safety  measures  in  external  circuits, 
i.e. not in the option board. This ensures safety 
in  the  system  if  an  abnormality  occurs  due  to 
malfunction  of  the  option  board  or  another 
external  factor  affecting  the  option  board 
operation.  Not  doing  so  may  result  in  serious 
accidents. 

WARNING 

Refer  to  the  section  “MX2  Inverter  Safety 
(ISO  13849-1)”  for  details  if  the  safety 
measures mentioned in the previous warning 
are  to  be  ensured  using  the  Gate  Suppress 
function of the MX2-A

 inverter. 

WARNING 

Emergency  stop  circuits,  interlock  circuits, 
limit  circuits,  and  similar  safety  measures 
must be provided in external control circuits. 

WARNING 

Fail-safe  measures  must  be  taken  by  the 
customer  to  ensure  safety  in  the  event  of 
incorrect,  missing,  or  abnormal  signals 
caused  by  broken  signal  lines,  momentary 
power  interruptions,  or  other  causes.  Not 
doing so may result in serious accidents. 

Caution 

Do  not  touch  the  inverter  during  power-on, 
and  immediately  after  power-off.  Hot  surface 
may cause injury. 

 

■ 

Operating Environment Precautions 

Caution

 

Do not operate the MX2-A

 inverter with a mounted 

3G3AX-MX2-EIP-A  option  board  in  the  following 
locations  (doing  so  may  result  in  malfunction, 
electric shock or burning): 

  Locations subject to direct sunlight  

  Locations  subject  to  temperatures  or  humidity  outside  the  range 

specified in the specifications  

  Locations subject to condensation as the result of severe changes in 

temperature 

  Locations subject to corrosive or flammable gases 

  Locations subject to dust (especially iron dust) or salts 

  Locations subject to exposure to water, oil, or chemicals  

  Locations subject to shock or vibration 

 

Caution

 

Take  appropriate  and  sufficient  countermeasures 
when  installing  systems  in  the  following  locations 
(doing so may result in malfunction): 

  Locations subject to static electricity or other forms of noise 

  Locations subject to strong electromagnetic fields 

  Locations subject to possible exposure to radioactivity 

  Locations close to power supplies 

 

Caution

 

The  operating  environment  of  the  MX2-A

  inverter 

with  a  mounted  3G3AX-MX2-EIP-A  option  board 
can  have  a  large  effect  on  the  longevity  and 
reliability  of  the  system.  Improper  operating 
environments  can  lead  to  malfunction,  failure,  and 
other  unforeseeable  problems  with  the  system. 
Make  sure  that  the  operating  environment  is  within 
the  specified  conditions  at  installation  and  remains 
within the specified conditions during the life of the 
system. 

 

■ 

Application Precautions 

WARNING

 

Failure  to  abide  by  the  following  precautions 
could  lead  to  serious  or  possibly  fatal  injury. 
Always read these precautions. 

  Always connect the grounding cable to one of the ground terminals of 

the MX2-A

 inverter. 

  Check  any  user  program  in  the  system  that  acts  as  a  EtherNet/IP 

master  before  actually  running  it.  Not  checking  the  program  may 
result in unexpected operation. 

 

Caution

 

Failure  to  abide  by  the  following  precautions  could 
lead  to  faulty  operation  of  the  option  board  or  the 
inverter, or could damage either of the two. Always 
read these precautions. 

  Install  external  breakers  and  take  other  safety  measures  against 

short-circuits  in  external  wiring.  Not  observing  this  may  result  in 
burning. 

  Be  sure  that  all  the  cable  connector  screws  are  tightened  to  the 

torque  specified  in  the  relevant  manuals.  Incorrect  tightening  torque 
may result in malfunction. 

  Do  not  allow  metal  clippings  to  enter  either  option  board  or  inverter 

when wiring or installing the unit. 

  Follow  the  network  configuration  and  wiring  instructions  provided  in 

the “EtherNet/IP Operation Manual” (Cat. No. W465). 

o

 

Wire the EtherNet/IP cables correctly. Incorrect wiring may result 
in burning. 

o

 

Wire  the  EtherNet/IP  connectors  correctly.  Incorrect  wiring  may 
result in burning. 

o

 

Apply  termination  at  both  ends  of  a  EtherNet/IP cable  segment. 
Do not apply termination anywhere else. 

  Be  sure  that  the  option  board  is  mounted  correctly.  Improper 

mounting may result in malfunction. 

  Disconnect  the  grounding  cable  when  performing  withstand  voltage 

tests. Not disconnecting the grounding cable may result in burning. 

  Check  the  inverter  settings  for  proper  inverter  behaviour  before 

actually operating the inverter remotely via the EtherNet/IP network. 

  Check  the  network  related  inverter  settings  regarding  EtherNet/IP 

node  address  and  EtherNet/IP  remote  I/O  allocation.  Not  doing  so 
may result in unexpected operation. 

  Check  the  inverter’s  EzSQ  program  and  its  interaction  with  the 

EtherNet/IP  master  before  actually  running  it  on  the  inverter.  Not 
checking the program may result in unexpected operation. 

  When  replacing  an  inverter  be  sure  that  all  inverter  settings  of  the 

inverter being replaced are restored to the replacement. 

  Parameters  for  the  module  are  stored  in  the  module  and  must  be 

restored  if  the  module  is  replaced.  The  setup  parameters  for  the 
3G3AX-MX2-EIP-A  are  not  stored  in  the  drive.  Always  check  the 
node  address  and  other  network  related  inverter  settings  after 
restore. 

  Confirm  that  no  adverse  effect  will  occur  at  the  moment  the 

EtherNet/IP  master  stops  communicating  with  the  inverter  or  at  the 
moment the EtherNet/IP master has not yet started communicating to 
the inverter. 

  Confirm that no adverse effect will occur in the inverter before force-

setting/force-resetting any bit in the system that acts as a EtherNet/IP 
master. 

■ 

Handling, Storage and Disposal

 

  Before touching the option board or inverter, be sure to first touch a 

grounded metallic object in order to discharge any static built-up. Not 
doing so may result in malfunction or damage. 

  When  transporting  or  storing  the  option  board,  cover  the  PCBs  with 

electrically  conductive  materials  to  prevent  electronic  components 
from being damaged by static electricity. Also keep the product within 
the specified storage temperature range. 

  Never  dispose  electrical  components  by  incineration.  Contact  your 

state  environmental  agency  for  details  on  disposal  of  electrical 
components and packaging in your area. 

■ 

Compliance with EC Directives

 

  This  product  complies  with  EC  Directives  when  mounted  on  an 

MX2-A

  inverter  and  having  connected  the  grounding  cable.  For 

grounding,  cable  selection,  and  any  other  conditions  for  EMC 
compliance, refer to the MX2 User’s Manual for installation. 

■ 

References

 

Please  be  sure  to  read  the  related  user  manuals  to  use  the 
3G3AX-MX2-EIP-A  option  board  safely  and  properly.  Be  sure  you 
are using the most current version of the manual. 

 

Name 

Cat No. 

3G3AX-MX2-EIP-A Option Board User’s Manual 

I36I 

MX2 User’s Manual 

I570 

EtherNet/IP Operation Manual 

W465 

 
 
 
 
 
 
 
 
 
 
 
 

SUITABILITY FOR USE 

OMRON shall not be responsible for conformity with any standards, codes, 
or regulations that apply to the combination of products in the customer’s 
application or use of the products. 
Take all necessary steps to determine the suitability of the product for the 
systems, machines, and equipment with which it will be used. 
Please know and observe all prohibitions of use applicable to the products. 
NEVER  USE  THE  PRODUCTS  FOR  AN  APPLICATION  INVOLVING 
SERIOUS  RISK  TO  LIFE  OR  PROPERTY  WITHOUT  ENSURING  THAT 
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE 
RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED 
AND  INSTALLED  FOR  THE  INTENDED  USE  WITHIN  THE  OVERALL 
EQUIPMENT OR SYSTEM. 

See also product catalogs for Warranty and Limitations of Liability

 

 

Reviews: