background image

E3X-DACLR

5

Nomenclature

Safety Precautions

Refer to 

Warranty and Limitations of Liability

.

This product is not designed or rated for 

ensuring safety of persons either directly or 

indirectly.

Do not use it for such purposes.

Do not use the product with voltage in excess 

of the rated voltage. Excess voltage may result 

in malfunction or fire.

Never use the product with an AC power 

supply. 

Otherwise, explosion may result.

High-temperature environments may result in

burn injury.

The following precautions must be observed to ensure safe 

operation of the Sensor.

1.  Do not use the Sensor in an environment where explosive 

or flammable gas is present.

2.  Do not use the Sensor in a location subject to splattering 

of water, oils, or chemicals.

3.  Do not attempt to disassemble, repair, or modify the 

Sensor.

4.  Do not apply voltages or currents that exceed the rated 

range to the Sensor.

5.  Do not use the Sensor in an ambient atmosphere or 

environment that exceeds the ratings.

6.  Wire the power supply correctly, including the polarity.

7.  Connect the load correctly.

8.  Do not short-circuit the load at both ends.

9.  Do not use the Sensor if the case is damaged.

10. Dispose of the Sensor as industrial waste.

11. Do not use the Sensor in locations subject to direct 

sunlight.

12. Burn injury may occur. The Sensor surface temperature 

rises depending on application conditions, such as the 

ambient temperature and the power supply voltage. Use 

caution when operating or performing maintenance on the 

Sensor.

Amplifier Units

Single colour

1 to 4 colour

ON when output is ON.
OFF when output is OFF.

Operation Indicator 

(orange)

Locks the fiber.

Lock lever

Incident level, function, etc.

Main Display (red)

Threshold, function settings, etc.

Sub-display (green)

Use to select SET
or RUN mode.

Mode Selector

Switch

Lit orange: Operation
in I Mode.

I Mode Indicator

Function setting operations

Operation Keys

Use to switch between Light ON
and Dark ON modes.

Operation Selector Switch

UP

DOWN

MODE

Locks the fiber.

Incident level, function, etc.

ON when output is ON.
OFF when output is OFF.

Ch1 Operation Indicator

Lock lever

Main Display (red)

Used to select the channel to
display and set.

Channel Switch

Use to select SET
or RUN mode.

Mode Selector Switch

ON when output is ON.
OFF when output is OFF.

Ch2 Operation Indicator

Function setting operations

Operation Keys

Threshold, function settings, etc.

Sub-display (green)

UP

DOWN

MODE

WARNING

CAUTION

Precautions for Safe Use

Summary of Contents for 323872

Page 1: ...At the end of this document you will find links to products related to this catalog You can go directly to our shop by clicking HERE HERE...

Page 2: ...ron representative 2 Models with 2 m PVC cable or M12 pigtail connector are available Contact your Omron representative Content list All products can be ordered separately under the following order co...

Page 3: ...lowable range Object teaching good sample with auto tolerance 2 point teaching good and bad sample Functions Operation mode ON for match ON for same color as registered color or ON for mismatch ON for...

Page 4: ...rted to Vcc ON 1 5 V max sourcing current 1 mA max OFF Vcc 1 5 V to Vcc leakage current 0 1 mA max PNP ON Shorted to Vcc sinking current 3 mA max OFF Open or shorted to 0 V ON Vcc 1 5 V to Vcc sinking...

Page 5: ...ut External input Orange Pink Ch1 operation indicator orange Photo electric Sensor main circuit Load Load Brown Black Blue 12 to 24 VDC Display Match Mismatch ON OFF ON OFF Operate Reset Output transi...

Page 6: ...Sensor if the case is damaged 10 Dispose of the Sensor as industrial waste 11 Do not use the Sensor in locations subject to direct sunlight 12 Burn injury may occur The Sensor surface temperature ris...

Page 7: ...er Unit s for which the Connector is to be removed away from the rest of the group 2 After the Amplifier Unit s has been separated press down on the lever on the Connector and remove it Do not attempt...

Page 8: ...nections EEPROM Writing Error If the data is not written to the EEPROM correctly due to a power failure or static electric noise initialize the settings with the keys on the Amplifier Unit ERR EEP wil...

Page 9: ...s Vinyl insulated round cable Standard length 2 m With Mounting Bracket Attached Main display Sub display Operation indicator Round I Mode indicator Oblong Operation indicator for channel 2 Area of di...

Page 10: ...ndicator Round I Mode indicator Oblong Operation indicator for channel 2 Area of digital indication Center of DIN track DIN track sold separately PFP N End Plate sold separately PFP M Multiple connect...

Page 11: ...Receive lens Sensing surface 10x24 5 Optical axis 2 lens 9 29 14 11 5 25 6 13 6 Optical fiber 2 2 Mounting holes 2 3 2 11 2 11 6 Type indicated tube Fiber unit E32 L15 M8x1 37 248 15 1 300 20 Fiber Am...

Page 12: ...E3X DACLR 11...

Page 13: ...utdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad sys...

Page 14: ...eal time Logistics systems for the shipment of materials almost anywhere in the world Purchasing management order record and tracking of shipments To access the product click on the green button Produ...