2JCIE-BL01-P1 Environment Sensor (PCB Type) User’s Manual (A280)
5
1.3.1
With Data Recording mode
The following Beacon Modes operate with data recording to the flash memory. To activate data
recording, 2.3.1 Time Information must be set from the Central device first. Time information is cleared
to zero (0) again when the Measurement Interval is changed, Beacon Mode is changed or power is reset.
In these cases, it is necessary to set Time Information again to restart data recording
.
Table 2. List of Beacon Mode with Data Recording
Beacon Mode
Name
Shortened Device Name
Device Name
0x00
Event Beacon (SCAN RSP)
Env
EnvSensor-BL01
0x01
Standard Beacon
Env
EnvSensor-BL01
0x07
Alternate Beacon
Env
EnvSensor-BL01
0x08
Event Beacon (ADV)
Env
EnvSensor-BL01
1.3.2
Without Data Recording mode
Since the measured data is not recorded to the flash memory in the following Beacon Modes, only
Latest Data is updated
.
Table 3. List of Beacon Mode without Data Recording
Beacon Mode
Name
Shortened Device Name
Device Name
0x02
General Broadcaster 1
IM
IM-BL01
0x03
Limited Broadcaster 1
IM
IM-BL01
0x04
General Broadcaster 2
EP
EP-BL01
0x05
Limited Broadcaster 2
EP
EP-BL01