10452491_V_1_0.DOC
23/27
®®
M
C
S-1250
REMOTE PAD
(6) AGC / GAIN-SELECTION
With the AGC switches you can determine the input level. With a combination of the switches „0“ and „1“ you
can select „OFF“, „150 mV“, „300 mV“ or „540 mV“.
(7) EXT MUTE / SYS ON
3.5 mm jack for relay operation. Via the Ext Mute
socket, you can mute the amplifier and via the Sys On
socket, you can disable other devices.
(8) NETWORK CONNECTORS RJ45
Connect these outputs with the Hub. We recommend a
maximum cable length of 200 meters.
(9) AC VOLTAGE-SELECTOR
Make sure that the selector is properly set.
(10) AC-CONNECTION with FUSEHOLDER
Used to plug the power cord in. Only replace the fuse
when the device is disconnected from mains. Only use
fuses of the same rating and power.
MCS-1250 Controller
LC-DISPLAY
Indicates the following information in succession: Volume, Zone, Treble and
Bass. The volume can be set between 00 to 63; the default setting is 48.
Zones are indicated by C1-C6; Treble and Bass can be adjusted between -9
and +9 .
LEDs (Vol., Function, Treble, Bass)
The corresponding LED lights green when the function is displayed. The LED
flashes when the parameters are being set.
REMOTE
For selecting a function (Level, Function, Treble, Bass).
POWER
Switches the controller on and off. The amplifier should be powered on
before.
SELECT
This button activates the IR remote control.
DOWN / UP
With these buttons you can adjust the parameters of the different functions
(Level, Function, Treble, Bass).