00015858.DOC VERSION 1.0
21/30
Never put heavy objects like speaker-systems, flightcased etc. on cables.
Never wind up cables tightly around the elbow, but rather sleek with an interior diameter of 20 to 30 cm.
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Operation modes
Stereo operation
Normal operation mode of an amplifier, in which every channel gets its own signal. The most commonly used
mode of amplifiers is stereo-operation at 4 Ohms. Make sure that the operation-mode-switch is correctly set.
Calculation number of speakers – impedance
E.g. 1 speaker à 8 Ohm = 8 Ohm
2 speakers à 8 Ohm = 4 Ohm (parallel)
2 speakers à 8 Ohm = 16 Ohm (in line)
3 speakers à 8 Ohm = 2.66 Ohm (parallel), only for amplifiers capable of handling 2 Ohms
2 speakers à 8 Ohm = 24 Ohm (in line)
4 speakers à 8 Ohm = 2 Ohm (parallel), only for amplifiers capable of handling 2 Ohms
N.B.:
The input-impedance of the speaker-systems should at least be the same or even higher than the output-
impedance of the amplifier.
OPERATION
After having connected your amplifier to the mains, turn both LEVEL controls counter-clockwise to Min-
position. The last device to be switched on is the amplifier.
When operating the amplifying system, please make sure that the loudspeakers always sound well. When
distorsions can be heard, either the amplifier or the loudspeaker is overloaded. Overloads can quickly lead to
amplifier or speaker damage.
In order to avoid damage, please reduce the volume immediately when distortions can be heard. When
speaker-systems are destroyed by overload, the guarantee becomes void.
Always check the sound pressure level with a meter in order to keep to the threshold.
If you want to switch off the system,
switch off the amplifier first
and then the pre-amplifiers in order to
avoid acoustic shocks on the speakers.