Balanced use with XLR connectors
1 = Ground / Shield
2 = Hot (+)
3 = Cold (-)
For unbalanced use pin 1 and pin 3 have to be bridged
Input
Output
5. INSTALLATION
The processor is provided for use as a table top unit or for installation into a 19" rack (483 mm). This rack
should be a double-door rack where you can open the front panel and the rear panel. The rack should be
provided with a cooling fan. When mounting the device into the rack, please make sure that there is enough
space around the device so that the heated air can be passed on. Steady overheating will damage your
device. You can fix the device with four screws M6 in the rack. If several devices are to be installed, make
sure that you leave 1 unit space between the devices.
6. CONNECTIONS
6.1 Audio units
All connections have to be made or changed only if the unit and all audio devices connected to it is/are
switched off!
The inputs and outputs of the
CL-266
are equipped with balanced XLR and ¼“ jack
connectors.
1. Connect the outputs of the audio sources to the INPUT jacks.
2. A PA amplifier for speakers, mixers or a subsequent unit with line level can be connected to the OUTPUT
jacks.
6.2
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.