background image

Page 8

Rear View with Dual AC Barrel Connector

NEVER ATTEMPT TO OPEN THE CHASSIS OR SERVICE THE

POWER SUPPLY OR FAN MODULE. OPENING THE CHASSIS

MAY CAUSE SERIOUS INJURY OR DEATH.

THERE ARE NO USER REPLACEABLE OR SERVICEABLE

PARTS IN THIS UNIT.

WARNING!!!

DC Power

This module is intended for installation in restricted access areas. (“Les matériels 

sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT”). A 

restricted access area can be accessed only through the use of a special key, or other 

means of security.
The over current protection for connection with centralized DC shall be provided in the 

building installation, and shall be a UL listed circuit breaker rated 20 Amps, and installed 

per the National Electrical Code, ANSI/NFPA-70.

The XM5 re/-20 to +/-60VDC inclusive or tolerance (48VDC @ 1.1 Amp max 

rated power).  Appropriate overloading protection should be provided on the DC power 

source outlets utilized.

Rear View with Dual DC Terminal Connector

Page 7

SW3

SW4

Function

OFF (DOWN) OFF (DOWN) ZTP process is disabled

ON (UP)

OFF (DOWN) Listen Mode

OFF (DOWN)

ON (UP)

Activate Mode

ON (UP)

ON (UP)

Standard Mode

ZTP Options

Zero Touch is disabled by default.  The ZTP process is configured by setting these DIP-

switches to the desired mode of operation..  The ZTP process is initiated at start-up.
Refer to the full user manual for more details on the ZTP process (041-09600-001x).

2) Installing the Module
Wall Mounting

The wall mounting height of the module should be less than or equal to 2 meters (6.6 

feet) from the floor.  Use the four mounting holes on the module to secure the module 

to the wall.  The module can accommodate #6 screws (not included).

Installation of the module should be such that the air flow in the front, back, side and 

top vents of the switch are not compromised or restricted.
The accessory cables should have their own strain relief and do not pull down on the 

module. 

Rack Mounting

The module can be rack mounted using the optional Rack Mount Shelf (8261-0).  Refer 

to the Rack Mount Shelf user manual (040-08261-001x) for the proper installation 

guidelines.  Follow the same guidelines above when rack mounting the module.

3) Apply Power
AC Power

To power the XM5 using the AC/DC adapter, connect the barrel plug at the end of the 

wire on the AC/DC adapter to the 2.5mm DC barrel connector (center-positive) on the 

back of the XM5.  Then connect the AC/DC adapter to an AC outlet.  Confirm the XM5 

has powered up properly by checking the status of the Power LED located on the front 

of the XM5. 
Depending on the model number of the module, a second power source is available.  

Use the same power supply installation procedure above for the second power supply.

Installation of the equipment should be such that the air flow in the front, back, side and 

top vents of the XM5 are not compromised or restricted.

Secure the grounding wire to the ground screws.  See the figure for the location of the 

grounding screws.