background image

Page 10

NEVER ATTEMPT TO OPEN THE CHASSIS OR

SERVICE THE POWER SUPPLY. OPENING THE

CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH.

THERE ARE NO USER REPLACEABLE OR

SERVICEABLE PARTS IN THIS UNIT.

WARNING!!!

Make sure to disconnect the power and ground cables before removing the equipment.

PoE Powered Chassis

On models with the PoE power feature, the RJ-45 Port A (the left port on the front of the 

chassis) can be configured as a PoE Powered Device (PD).  It accepts power from a 

UTP-based Power Sourcing Equipment (PSE) and supports the following PoE standards:

Front View 1-Module Redundant Power Chassis

PoE RJ-45 (left most RJ-45 port)

• 

IEEE 802.3af-2003 Alternative A – power over data wires

• 

IEEE 802.3af-2003 Alternative B – power over spare wires

• 

Pre-Standard Cisco PoE – power over spare wires, with reversed polarity (older 

Cisco switches)

The following table summarizes the RJ-45 pinouts for each of the three PoE Standards 

supported by this product.

IEEE  

Standard

PSE  

Voltage  

Range (VDC)

Pin

1

Pin

2

Pin

3

Pin 

4

Pin 

5

Pin 

6

Pin 

7

Pin 

8

802.3af

46.0 to 57.0

RX, 

DC+

RX, 

DC+

TX,  

DC-

Spare Spare TX,  

DC-

Spare Spare

802.3at

51.0 to 57.0

RX

RX

TX

DC+

DC+

TX

DC-

DC-

Pre-standard

Cisco

51.0 to 57.0

RX

RX

TX

DC-

DC-

TX

DC+

DC+

RJ-45 Port B does not support the PoE feature.

Page 9

WARNING REGARDING EARTHING GROUND:

o

o

o

o

This equipment shall be connected to the DC supply

system earthing electrode conductor or to a bonding
jumper from an earthing terminal bar or bus to which the
DC supply system earthing electrode is connected.

This equipment shall be located in the same immediate

area (such as adjacent cabinets) as any other equipment
that has a connection between the earthed conductor of
the same DC supply circuit and the earthing conductor,
and also the point of earthing of the DC system. The DC
system shall not be earthed elsewhere.

The DC supply source is to be located within the same

premises as this equipment.

There shall be no switching or disconnecting devices in

the earthed circuit conductor between the DC source and
the earthing electrode conductor.

Locate the DC circuit breaker of the external power source, and switch the circuit 

breaker to the OFF position.
Prepare a power cable using a three conductor insulated wire (not supplied) with 12AWG 

to 14AWG thickness.  Cut the power cable to the length required.
Strip approximately 3/8 of an inch of insulation from the power cable wires.
Connect the ground wire to the grounding screws on the back of the module.
Connect the power cables to the module by fastening the stripped ends to the DC 

power connector.

Rear View 1-Module Redundant Power Chassis

AC/DC with 2 Pin Terminal

WARNING:  The positive lead of the power source must be connected to the 

“+” terminal on the module and the negative lead of the power source to the “-“ 

terminal on the module as shown above. 
WARNING: Note the wire colors used in making the positive, negative and ground 

connections. Use the same color assignment for the connection at the circuit 

breaker.

Connect the power wires to the circuit breaker and switch the circuit breaker ON. If any 

module are installed, the Power LED will indicate the presence of power.
During the installation, ensure that the ground potentials are maintained throughout 

the system connections.  This includes but not limited to the power source ground and 

any shielded cabling grounds.

Summary of Contents for iConverter 8245-11pt

Page 1: ...oduct with at least the same functionality For warranty service the product must be sent to an Omnitron designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method Limitation of Warranty The foregoing warranty shall not apply to product malfunctions resulting from improper or inadequat...

Page 2: ...ptions and variety of power connection types By utilizing the optional RJ 45 ports the chassis can be powered from a connected Power Sourcing Equipment PSE Optional contact closure sensors are provided for connection to external alarm indicators By installing a managed iConverter module into the chassis the chassis functions can be remotely managed by Telnet and SNMP software such as Omnitron s Ne...

Page 3: ...ultiple redundant load sharing power configurations The power is connected to the back of the chassis with connectors labeled Pwr1 and Pwr2 Pwr1 is the primary power connection and Pwr2 is the backup There are four primary power options and two backup options The combinations of primary and backup power include low voltage barrel connector low voltage terminal high voltage terminal and PoE from th...

Page 4: ...ing a three conductor insulated wire not supplied with 12AWG to 14AWG thickness Cut the power cable to the length required Strip approximately 3 8 of an inch of insulation from the power cable wires Connect the ground wire to the ground terminal on the chassis by fastening the stripped end to the DC power connector ground Connect the power cables to the chassis by fastening the stripped ends to th...

Page 5: ...such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and also the point of earthing of the DC system The DC system shall not be earthed elsewhere The DC supply source is to be located within the same premises as this equipment There shall be no switching or disconnecting devices in the earthed ...

Page 6: ...nector has the following pin configuration Pin Description Closed Open 1 Sensor 1 No Alarm Alarm 2 Signal Return RT 3 Sensor 2 No Alarm Alarm 4 Signal Return RT Sensor 3 No Alarm Alarm Signal Return RT Sensor 4 No Alarm Alarm Signal Return RT Contact Closure Sensors Pinout Configuration LED Indicators The following table details the LED status indicators LED Function Legend Color OFF State ON Blin...

Page 7: ...can only by configured from the Module Screen options Select the appropriate option to change the DIP switch setting The Module Screen also provides access to the status and control screen To select the Status Screen enter S For models with UTP ports the Control Screen is available to enable or disable Port A and Port B To select the Control Screen enter C Applications Battery Backup with Alarms W...

Page 8: ...y 5 and higher Sensors 16 to 24 gauge AC Power Requirements AC Adapter 100 240VAC 50 60Hz 0 2A 120VAC typical DC Power Requirements DC Input Terminal Block 9 24VDC 1 5A 9VDC typical 2 Pin Terminal non isolated DC Input Terminal Block 24 60VDC 0 3A 48VDC 3 Pin Terminal isolated DC Input AC Adapter 9 24VDC 1 5A 9VDC typical 2 5mm Barrel Connector DC Input PoE 44 57VDC 0 27A 48VDC typical RJ 45 Alter...