background image

Page 3

WEEE directive: (a) Do not dispose waste equipment with unsorted municipal and 

household waste. (b) Collect equipment waste separately. (c) Return equipment using 

collection method agreed with Omnitron.

 The equipment is marked with the WEEE symbol shown to indicate that it must 

be collected separately from other types of waste. In case of small items the symbol 

may be printed only on the packaging or in the user manual. If you have questions 

regarding the correct disposal of equipment go to www.omniton-systems.com/support 

or e-mail to Omnitron at [email protected]

Safety Warnings and Cautions

  ATTENTION: Observe precautions for handling electrostatic discharge sensitive 

devices.

  WARNING:  Potential damage to equipment and personal injury.

  WARNING:  Risk of electrical shock.

Customer Support Information

Phone:   

(949) 250-6510

Fax: 

 

(949) 250-6514

Address:  

Omnitron Systems Technology, Inc.

  38 

Tesla

 

 

Irvine, CA 92618, USA

Email:  

[email protected]

URL: 

 

www.omnitron-systems.com 

      

Page 4

iConverter

®

 1-Module Redundant Power Chassis

User Manual

Product Overview

The iConverter 1-Module chassis features a number of redundant power inputs, RJ-45 

port and alarm options.  It supports primary and secondary power input options and 

variety of power connection types.  By utilizing the optional RJ-45 ports, the chassis 

can be powered from a connected Power Sourcing Equipment (PSE).  Optional contact 

closure sensors are provided for connection to external alarm indicators.  By installing 

a managed iConverter module into the chassis, the chassis functions can be remotely 

managed by Telnet and SNMP software such as Omnitron’s NetOutlook

®

 Management 

software. 
This User Manual describes the following models:

Model 

Number

Contact 

Closure

Two  

RJ-45 

Ports

Primary Power Input

Backup Power Input

DC Input

Barrel

DC Input

2-Pin  

Terminal

DC Input

3-Pin  

Terminal 

PoE  

Power

RJ-45

DC Input

Barrel

DC Input

2-Pin 

Terminal

8245-11pt

X

X

8246-11pt

X

X

X

8246-51pt

X

X

X

8247-11pt

X

X

X

8247-12pt

X

X

X

8247-220t

X

X

X

8247-31pt

X

X

X

8247-320t

X

X

X

8248-11pt

X

X

X

X

8248-12pt

X

X

X

X

8248-220t

X

X

X

X

8248-31pt

X

X

X

X

8248-320t

X

X

X

X

8248-51pt

X

X

X

X

8248-520t

X

X

X

X

Use the 

Power Calculator

 to verify the iConverter chassis power supplies will meet the 

requirements of the installation.

Backplane Architecture

The chassis features two Ethernet backplane buses (A and B) that operate at 

10/100Mbps.  Both buses are enabled by default.  When an iConverter module that 

supports Ethernet backplane connectivity is installed in the chassis, the A bus connects 

directly to the RJ-45 Port A, and the B bus connects directly to the RJ-45 Port B. .

040-08245-001E   10/22

Summary of Contents for iConverter 8245-11pt

Page 1: ...oduct with at least the same functionality For warranty service the product must be sent to an Omnitron designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method Limitation of Warranty The foregoing warranty shall not apply to product malfunctions resulting from improper or inadequat...

Page 2: ...ptions and variety of power connection types By utilizing the optional RJ 45 ports the chassis can be powered from a connected Power Sourcing Equipment PSE Optional contact closure sensors are provided for connection to external alarm indicators By installing a managed iConverter module into the chassis the chassis functions can be remotely managed by Telnet and SNMP software such as Omnitron s Ne...

Page 3: ...ultiple redundant load sharing power configurations The power is connected to the back of the chassis with connectors labeled Pwr1 and Pwr2 Pwr1 is the primary power connection and Pwr2 is the backup There are four primary power options and two backup options The combinations of primary and backup power include low voltage barrel connector low voltage terminal high voltage terminal and PoE from th...

Page 4: ...ing a three conductor insulated wire not supplied with 12AWG to 14AWG thickness Cut the power cable to the length required Strip approximately 3 8 of an inch of insulation from the power cable wires Connect the ground wire to the ground terminal on the chassis by fastening the stripped end to the DC power connector ground Connect the power cables to the chassis by fastening the stripped ends to th...

Page 5: ...such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and also the point of earthing of the DC system The DC system shall not be earthed elsewhere The DC supply source is to be located within the same premises as this equipment There shall be no switching or disconnecting devices in the earthed ...

Page 6: ...nector has the following pin configuration Pin Description Closed Open 1 Sensor 1 No Alarm Alarm 2 Signal Return RT 3 Sensor 2 No Alarm Alarm 4 Signal Return RT Sensor 3 No Alarm Alarm Signal Return RT Sensor 4 No Alarm Alarm Signal Return RT Contact Closure Sensors Pinout Configuration LED Indicators The following table details the LED status indicators LED Function Legend Color OFF State ON Blin...

Page 7: ...can only by configured from the Module Screen options Select the appropriate option to change the DIP switch setting The Module Screen also provides access to the status and control screen To select the Status Screen enter S For models with UTP ports the Control Screen is available to enable or disable Port A and Port B To select the Control Screen enter C Applications Battery Backup with Alarms W...

Page 8: ...y 5 and higher Sensors 16 to 24 gauge AC Power Requirements AC Adapter 100 240VAC 50 60Hz 0 2A 120VAC typical DC Power Requirements DC Input Terminal Block 9 24VDC 1 5A 9VDC typical 2 Pin Terminal non isolated DC Input Terminal Block 24 60VDC 0 3A 48VDC 3 Pin Terminal isolated DC Input AC Adapter 9 24VDC 1 5A 9VDC typical 2 5mm Barrel Connector DC Input PoE 44 57VDC 0 27A 48VDC typical RJ 45 Alter...

Reviews: