Omnitron Systems Technology RuggedNet 10GPoE+/Si User Manual Download Page 5

Page 9

The module will return to the primary Port F1 after the failure condition has been 

restored for 6 seconds.

SW5:  MAC Learning - “MAC Learning/Off”

When this DIP-switch is in the LEFT “MAC Learning” position (factory default), all 

ports on the module will learn the source MAC address of each received packet and 

store the address so packets destined for the stored addresses can be forwarded 

to the appropriate port on the module. When the DIP-switch is in the RIGHT “Off” 

position, learning is turned off and all received unicast packets are forwarded to 

all ports.

SW6: Pause - “Pause Off/On”

Setting the DIP-switch to the LEFT “Pause Off” position (factory default) configures 

the module to advertise no Pause capability on all ports.  Setting this DIP-switch 

to the RIGHT “On” position configures the module to advertise Symmetrical and 

Asymmetrical Pause capability to all ports.  

SW7: L2CP - “L2CP Tunnel/Discard”

When this DIP-switch is in the LEFT “L2CP Tunnel” position (factory default), all 

L2CP frames will be tunneled through the module.  When this DIP-switch is in the 

RIGHT “Discard” position, all L2CP frames will be discarded.

SW8:  PSE Reset - “Off/PoE Reset”

The module can be configured to disable (reset) the PoE output power for 5 seconds 

after a loss of receive link on any uplink port.  This feature is typically used to allow 

a PD to re-initialize after a failure on the incoming uplink.  

When this DIP-switch is in the LEFT “Off” position (factory default), PoE output power 

does not reset on a loss of receive link on any uplink port.  When this DIP-switch is 

in the RIGHT “PoE Reset” position, the module will disable PoE output power for 5 

seconds following a loss of receive link on any uplink port.  
When uplink redundancy is enabled, the loss of link on either F1 or F2 will not cause 

the PD to be re-initialized even though the PSE Reset is enabled.  The PD will be 

re-initialized on a loss of receive link on both uplink ports.
When Dual Device Mode is enabled, the loss of receive link on a uplink port will 

re-initialize the PDs associated with that uplink port.  On models with 4 RJ-45 user 

ports, ports P1 and P2 will drop PoE power when a loss of receive link on F1 is 

detected and ports P3 and P4 will drop PoE power when a loss of receive link on 

F2 is detected.  On models with 8 RJ-45 user ports, P1 - P4 will drop PoE power 

when a loss of receive link on F1 is detected and ports P5 - P8 will drop PoE power 

when a loss of receive link on F2 is detected.

Page 10

2) Installing the Module

The module can be wall or rack mounted using the optional Wall Mount Plate 

(8260-3).  Refer to the Wall Mount Plate user manual (040-08260-301x) for the 

proper installation guidelines.

Wall Mounting

The wall mounting height of the module should be less than or equal to 2 meters 

(6.6 feet) from the floor.  Use the four mounting holes on the module to secure the 

module to the wall.  The module can accommodate #6 screws (not included).

Installation of the module should be such that the air flow in the front, back, side 

and top vents of the switch are not compromised or restricted.
The accessory cables should have their own strain relief and do not pull down on 

the module. 

Rack Mounting

The module can be rack mounted using the optional Rack Mount Shelf (8260-0).  

Refer to the Rack Mount Shelf user manual (040-08260-001x) for the proper 

installation guidelines.
Follow the same guidelines above when rack mounting the module.

3) Apply DC Power

This module is intended for installation in restricted access areas. (“Les matériels 

sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT”). 

A restricted access area can be accessed only through the use of a special key, or 

other means of security.
The over current protection for connection with centralized DC shall be provided in 

the building installation, and shall be a UL listed circuit breaker rated 20 Amps, and 

installed per the National Electrical Code, ANSI/NFPA-70.
The 6 Port /Si re48 to +57VDC inclusive of tolerance (2.33A 

@ 56VDC max rated power).  The 10 Port /Si re46 to +57VDC 

inclusive of tolerance (4.49A @ 56VDC max rated power).  See specification table 

for specific model requirements. 

Appropriate overloading protection should be provided on the DC power source 

outlets utilized.

Top View with DC Power Connector

WARNING:

Only a DC power source that complies with

safety extra low voltage (SELV) requirements can be
connected to the DC-input power supply.

Summary of Contents for RuggedNet 10GPoE+/Si

Page 1: ...ring this product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option repair or replace a product which is proven...

Page 2: ...nings and Cautions ATTENTION Observe precautions for handling electrostatic discharge sensitive devices WARNING Potential damage to equipment and personal injury WARNING Risk of electrical shock WARNI...

Page 3: ...led SW6 LEFT Off Pause Disabled factory default RIGHT Pause Pause Enabled SW7 LEFT L2CP Tunnel L2CP Tunnel factory default RIGHT Discard L2CP Tunnel Discard SW8 LEFT Off PoE Reset Disabled factory def...

Page 4: ...P3 and P4 are only forwarded to uplink port F2 When models with 8 RJ 45 user ports are configured for Dual Device Mode and Directed Switch Mode the traffic from ports P1 P4 is only forwarded to uplink...

Page 5: ...ill drop PoE power when a loss of receive link on F1 is detected and ports P3 and P4 will drop PoE power when a loss of receive link on F2 is detected On models with 8 RJ 45 user ports P1 P4 will drop...

Page 6: ...shown above WARNING Note the wire colors used in making the positive negative and ground connections Use the same color assignment for the connection at the circuit breaker Connect the power wires to...

Page 7: ...linked at 10M 100M or 1G Green two blinks Port linked at 2 5G Green three blinks Port linked at 5G Green four blinks Port linked at 10G SFP Uplink Ports LED Indicators LED Indicators RJ 45 User Ports...

Page 8: ...erature Extended 40 to 75 C Storage 40 to 80 C Humidity 5 to 95 non condensing Altitude 100m to 4 000m operational MTBF hours 280 000 Warranty 5 year product warranty with 24 7 365 free Technical Supp...

Reviews: