Omnitron Systems Technology RuggedNet 10GPoE+/Si User Manual Download Page 4

Page 7

Directed Switch Mode Dual Uplink Port

When models with two uplink ports are configured for Directed Switch Mode and 

Uplink Redundancy (per DIP-switches 3 and 4), traffic is forwarded to both the 

primary and secondary uplink ports.  The secondary port will block all traffic while 

the primary port is active.  When the primary port goes down, the secondary port 

will be active and all traffic will be forwarded out the secondary port (F2).

Directed Switch Mode with Uplink Redundancy

Dual Device Mode

When configured for Dual Device Mode, the module is configured as two logically 

independent Layer 2 switches.  On models with 4 RJ-45 user ports, Port F1 is 

associated with ports P1 and P2 and Port F2 is associated with ports P3 and P4.  

On models with 8 RJ-45 user ports, Port F1 is associated with ports P1 - P4 and 

Port F2 is associated with ports P5 - P8. Data flow will follow MAC address mapping.

Dual Device Mode

When models with 4 RJ-45 user ports are configured for Dual Device Mode and 

Directed Switch Mode, the traffic from ports P1 and P2 is only forwarded to uplink 

Page 8

port F1 and ports P3 and P4 are only forwarded to uplink port F2.  When models with 

8 RJ-45 user ports are configured for Dual Device Mode and Directed Switch Mode, 

the traffic from ports P1 - P4 is only forwarded to uplink port F1 and ports P5 - P8 

are only forwarded to uplink port F2. This prevents broadcast traffic from flooding 

other network ports.  Incoming traffic from F1 and F2 follows MAC address mapping.  

Dual Device with Directed Switch Mode

SW3 and SW4:  Uplink Redundancy

The modes are described with MAC learning enabled.  When MAC learning is 

disabled, the module will send data to all ports.

SW3

SW4

Function

LEFT

LEFT

Switch Mode (factory default)

LEFT

RIGHT

Switch Mode (factory default)

RIGHT

LEFT

Redundant Mode - no return to primary (F1)

RIGHT

RIGHT

Redundant Mode - return to primary (F1)

Uplink Redundancy

When  configured  for  Uplink  Redundant  Mode  “no  return  to  primary”,  the  uplink 

ports operate as redundant links.  A fault on the primary Port F1, will cause a fail 

over to the secondary Port F2 within 50msec.  Port F1 will become the secondary 

port once the failure condition has been restored because “no return to primary” 

has been selected.

Redundant Uplink

When configured for Uplink Redundant Mode “return to primary’, a fault on the 

primary Port F1, will cause a fail over to the secondary Port F2 within 50msec.  

Summary of Contents for RuggedNet 10GPoE+/Si

Page 1: ...ring this product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option repair or replace a product which is proven...

Page 2: ...nings and Cautions ATTENTION Observe precautions for handling electrostatic discharge sensitive devices WARNING Potential damage to equipment and personal injury WARNING Risk of electrical shock WARNI...

Page 3: ...led SW6 LEFT Off Pause Disabled factory default RIGHT Pause Pause Enabled SW7 LEFT L2CP Tunnel L2CP Tunnel factory default RIGHT Discard L2CP Tunnel Discard SW8 LEFT Off PoE Reset Disabled factory def...

Page 4: ...P3 and P4 are only forwarded to uplink port F2 When models with 8 RJ 45 user ports are configured for Dual Device Mode and Directed Switch Mode the traffic from ports P1 P4 is only forwarded to uplink...

Page 5: ...ill drop PoE power when a loss of receive link on F1 is detected and ports P3 and P4 will drop PoE power when a loss of receive link on F2 is detected On models with 8 RJ 45 user ports P1 P4 will drop...

Page 6: ...shown above WARNING Note the wire colors used in making the positive negative and ground connections Use the same color assignment for the connection at the circuit breaker Connect the power wires to...

Page 7: ...linked at 10M 100M or 1G Green two blinks Port linked at 2 5G Green three blinks Port linked at 5G Green four blinks Port linked at 10G SFP Uplink Ports LED Indicators LED Indicators RJ 45 User Ports...

Page 8: ...erature Extended 40 to 75 C Storage 40 to 80 C Humidity 5 to 95 non condensing Altitude 100m to 4 000m operational MTBF hours 280 000 Warranty 5 year product warranty with 24 7 365 free Technical Supp...

Reviews: