DIP-switch is in the RIGHT “EN” position, 

the  Backplane  Port  is  enabled.    This 

allows Ethernet Backplane connectivity 

to an adjacent module via the chassis 

Backplane Link “A” or “B” depending on 

the switch setting.

Sw4 - MASTER/SlAVE

When the 10/100M2 module is installed in 

a chassis with an Network Management 

Module (NMM2), set the DIP-switch to 

the LEFT “M/SL” position (factory default). The assignment of mastership is automatically 

negotiated by the installed management modules.  To designate the 10/100M2 module 

as the master of the chassis, set the DIP-switch on the module to the LEFT “M/SL” 

position, and set the other installed management modules’ DIP-switches to the RIGHT 

“SL” position to enable Slave-Only mode.

2)  InSTAll MoDUlE In ChASSIS AnD ConnECT CABlES

a.  Carefully slide the module into an open slot in the chassis.  Align the module with 

the  installation  guides  and  ensure  that  the  module  is  firmly  seated  against  the 

backplane. Secure the module by fastening the front panel thumbscrew (push in and 

turn clockwise to tighten) to the chassis front.

 

 Verify the “Pwr” LED is ON (indicating 

the chassis is powered).

b.  When using a 10/100M2 SFP model (8919N-0), insert the SFP Fiber transceiver 

into the Port 1 SFP receptacle on the 10/100M2.   

  noTE:  The release latch of the SFP Fiber transceiver must be in the closed 

position before insertion.

c.   Connect an appropriate multimode or single-mode fiber cable to the fiber port of the 

installed module. It is important to ensure that the transmit (TX) is attached to the 

receive side of the device at the other end and the receive (RX) is attached to the 

transmit side. Single-fiber (SF) media converter models operate in pairs.  The TX 

wavelength must match the RX wavelength at the other end and the RX wavelength 

must match the TX wavelength at the other end. 

d.  Connect  the  UTP  port  via  a  Category  5  cable  to  a  10BASE-T  or  100BASE-TX  

Ethernet device.

3)  ConFIGURE MoDUlE VIA CoMMAnD lInE InTERFACE

To access the Command Line Interface (CLI), connect the 10/100M2 RS-232 Console 

Port to the COM port of a computer equipped with terminal emulation software such as 

HyperTerminal.  The Console Port (DCE) is a mini DIN-6 female connector which can 

be changed to a DB-9 connector with the included adapter.  The 10/100M2 Console 

Port  is a standard asynchronous serial interface.  
Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect 

To:” window.  Set the serial port to the following:
Bits Per Second    

57,600

Stop Bits  

 

1

Data Bits  

 

8

Parity   

 

NONE

Hardware Flow Control 

NONE

Switch

left

(Factory Default)

Right

Sw1

off:

Pause Disable

PAUS:

Pause Enable

Sw2

FDX: 

Fiber Full-Duplex

hDX:

Fiber Half-Duplex

Sw3

An:

UTP Auto-Negotiate

MAn:

UTP Manual

Sw4

100:

UTP 100Mbps

10:

UTP 10Mbps

Sw5

FDX:

UTP Full-Duplex

hDX:

UTP Half-Duplex

Sw6

See link Mode Selection

Sw7

Sw8

              

Sw6

Sw7

Sw8

link Mode Selection

Left

Left

Left

link Segment (lS)

(Factory Default)

Right

Left

Left

link Propagate (lP)

Left

Right

Left

Remote Fault  link 

Segment (RFD + lS)

Right

Right

Left

Remote Fault  link 

Propagate (RFD + lP)

Left

Left

Right

Symmetrical Fault Detect (SFD)

Right

Left

Right

Asymmetrical link Propagate

Port 1 to Port 2 (AlP P1-P2)

Left

Right

Right

Asymmetrical link Propagate

Port 2 to Port 1 (AlP P2-P1)

Right

Right

Right

Asymmetrical RFD + lP

Figure B:  DIP-Switch Bank 1

Sw3, Sw4 AnD Sw5 - UTP ConTRol

DIP-switches SW3, SW4 and SW5 control the setting of the UTP port.  See Figure C below 

for the UTP Configuration matrix.

noTE:  Refer to the table in Section 3.2.1.3 of the 10/100M2 User Manual for the 

more detailed information.

Sw3

Sw4

Sw5

Function

AN

100

FDX

The UTP port is set to auto-negotiation with the following modes advertised:  

100F, 100H, 10F, 10H

AN

100

HDX

The UTP port is set to auto-negotiation with the following modes advertised:  

100H, 10F, 10H

AN

10

FDX

The UTP port is set to auto-negotiation with the following modes advertised:  

10F, 10H

AN

10

HDX

The UTP port is set to auto-negotiation with the following modes advertised:  

10H

MAN

100

FDX

The UTP port is set to manual negotiation and is forced to:

100F

MAN

100

HDX

The UTP port is set to manual negotiation and is forced to:

100H

MAN

10

FDX

The UTP port is set to manual negotiation and is forced to:

10F

MAN

10

HDX

The UTP port is set to manual negotiation and is forced to:

10H

Figure C:  UTP Configuration Matrix

 

Sw6, Sw7, Sw8 - lInK MoDES 

These three DIP-switches configure the link mode settings. It is recommended to have 

link modes DOWN (default) during the initial installation. After the circuit has been tested 

and operational, configure the module for the desire mode.  For detailed information on 

the operation of the different Link Modes, download the application note “

iConverter

 

Link Modes” available on Omnitron’s web site.

DIP-SwITCh BAnK 2

Sw1, Sw2 - BACKPlAnE EnABlE

When  the  DIP-switch  is  in  the  LEFT  “DS”  position  (factory  default),  the  Backplane 

Port of the 10/100M2 is isolated from the chassis’ Ethernet  Backplane.  When the 

Switch

left (Factory Default)

Right

Sw1

A-DS:

 Disabled 

Backplane Port A

A-En:

 Enabled

Backplane Port A

Sw2

B-DS:

 Disabled

Backplane Port B

B-En:

 Enabled

Backplane Port B

Sw3

Reserved

Reserved

Sw4

M/Sl:

Master/Slave Auto-Select

Sl:

Slave-Mode Only

Sw5 - Sw8

Reserved

Reserved

Figure D: DIP-Switch Bank 2

Page 2

Page 3