Quadra-Fire  •  Topaz  •  7009-113  Rev. N  •  5/13

Service Parts

Topaz

Beginning Manufacturing Date: Apr. 2002 

Ending Manufacturing Date: Active

R

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement 
parts for your appliance please provide model number and serial number. All parts listed 
in this manual may be ordered from an authorized dealer.

Stocked

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

Paint, 12 oz Can - Qty: 1

Sienna Bronze/Espresso

PAINT1-CSB/CES

Y

Willow/Tuscan Olive

PAINT1-CWL/CTO

Y

Piezo Ignitor -Black Knob

291-513

Y

Plate, Damper

468-0360

Regulator, Conversion, Sit, NG

230-1570

Y

Relief Door Assembly

7011-011

Switch, Rocker

230-0730

Y

Thermopile/Generator, Millivolt

842-0250

Y

Top Mount

468-0420

Topaz Shipping Kit

842-5140

Wire Harness

7010-156

Conversion Kit, LP

844-9230

Y

Injector, Pilot, Ez, LP, 35

200-2630

Y

Orifi ce LP (.073)

Top Vent

24220

Y

Orifi ce, LP (.063)

Rear Vent

17236

Y

Orifi ce, Pilot, Pse, LP

844-8490

Y

Regulator, Conversion, Sit, LP

230-1520

Y

Additional service part numbers appear on following page.

Summary of Contents for TOPAZ 839-1290

Page 1: ...y or death This appliance may be installed as an OEM installation in manufactured home USA only or mobile home and must be installed in accordance with the manufacturer s instructions and the manufact...

Page 2: ...chnicien qualife et ou muni d une licence de mani re respecter les r glements municipaux Dans la R publique de Massachusetts l installation doit tre effectu e par un plombier ou un installateur d appa...

Page 3: ...onversions 23 B Gas Pressures 25 C Gas Connection 26 Section 7 Electrical Information A Recommendation for Wire 27 B Connecting to the Appliance 27 C Standing Pilot Ignition System Wiring 27 Section 8...

Page 4: ...ass WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas con...

Page 5: ...t terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBST...

Page 6: ...Remove log set and component pack from firebox Report to your dealer any parts damaged in shipment particularly the condition of the glass Read all of the instructions before starting the instal latio...

Page 7: ...ce to all clearance specifications in manual WARNING B Clearances Figure 3 1 Model A B C D E F G Topaz Inches 6 1 2 6 1 54 36 40 23 Millimeters 165 152 25 1372 914 1016 584 NOTE Flooring beneath appli...

Page 8: ...LOWEST DISCHARGE OPENING Roof Pitch H Min Ft Flat to 6 12 1 0 Over 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12 2 0 Over 9 12 to 10 12 2 5 Over 10 12 to 11 12 3 25 Over 11 12 to 12 12 4 0...

Page 9: ...AX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2 3 x Q ACTUAL 4 caps 12 feet 1 2 x Q ACTUAL QMIN termination caps x 3 RMA X 2 termination caps xQACTUAL N 6 inches non vinyl side...

Page 10: ...gonal runs have both vertical and horizontal vent aspects when calculating the effects Use the rise for the vertical aspect and the run for the horizontal aspect See Figure 5 1 Two 45 elbows may be us...

Page 11: ...s 6 in 152mm Horizontal sections require a 1 4 in 6mm rise for every 12 in 305mm of horizontal travel Exterior Vent Diameter 6 5 8 in 168mm Inner Vent Diameter 4 in 102mm Horizontal sections require n...

Page 12: ...wist lock adapter is built into the appliance at the factory Wall thickness may vary Remember to include wall thickness in minimum clearances when figuring venting lengths for your installation needs...

Page 13: ...grade i e basement application proper drainage must be provided to prevent water from entering the snorkel termination Do not backfill around snorkel termination HOT HOT WOOD SCREW WALL THIMBLE Step 4...

Page 14: ...op to vinyl standoff SCREWS Apply sealant to all four sides VINYL SIDING Figure 5 8 8 in 203mm 7 in 178mm 7 in 178mm 6 in 152mm Figure 5 7 NOTE Some termination caps may cause the vent pipe to be off...

Page 15: ...p 2 Set the gas appliance in its desired location Drop a plumb bob down from the ceiling to the position of the appliance flue exit and mark the location where the vent will penetrate the ceiling Dril...

Page 16: ...equirements as outlined in the current CAN CGA B149 Installation Codes in Canada the National Fuel Gas Code NFPA 54 ANSI Z223 1 in USA or local codes Note that for steep roof pitches the vent height m...

Page 17: ...amed and sheetrocked with standard construction materials however refer to these installation instructions for the minimum allowable clearance between the outside of the vent pipe and the combustible...

Page 18: ...thing Step 5 Using tin snips cut the support box from the top corners down to the roofline and fold the resulting flaps over the roof sheathing Figure 5 18 Before nailing it to the roof run a bead of...

Page 19: ...Connect the flex pipe to the retro connector and attach with sheet metal screws Step 6 Push the flex pipe back up into the ceiling support box center the retro connector and attach it to the support...

Page 20: ...x Liner Pipe Length Optional Chimney Liner Termination Cap Co Axial to Co Linear Connector 30 ft 9m of 3 in 76mm Flex Liner Exhaust Section Pipe Length Optional 4 ft 1m of 3 in 76mm Flex Liner Air Int...

Page 21: ...gth extended to its nominal length Be sure to leave 2 3 in 51 76mm of flex above the existing chimney to allow for connection to the termination kit Step 3 Secure the flashing to the top of the masonr...

Page 22: ...the top adapter to the flashing Use three sheet metal screws through the side of the top adapter into the flange on the flashing Figure 5 28 Twist lock the high wind termination cap on to the top ada...

Page 23: ...nd lifting the burner out Figure 6 3 Remove the three screws on the front of the burner support Set screws aside Figure 6 5 Remove the main burner orifice using a 5 8 in wrench and replace the orifice...

Page 24: ...move the rods and adapter cap Fire Risk Explosion Risk Disconnect any electrical cords and turn off gas supply to unit before proceeding if converting fuel on an appliance already fully installed WARN...

Page 25: ...ow Proper input pressures required for optimum appliance per formance gas line sizing requirements need to be followed from NFPA51 WARNING Fire Risk Explosion Hazard High pressure will damage valve Di...

Page 26: ...local building codes if any If not follow ANSI Z223 1 Instal lation should be done by a qualified installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts in...

Page 27: ...ppliance 4 Use low resistance thermostat wire for wiring from igni tion system to the wall switch and thermostat 5 Use the following chart for wire sizing 6 Keep wire lengths as short as possible by r...

Page 28: ...trols Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Shock hazard Replace damaged wire with type 105O C rated wire Wire must have high temperature ins...

Page 29: ...lling as indi cated in Figure 8 6 Figure 8 2 Remove inner collar adapter KIT CONTENTS Rear vent grille NG orifice 113 LP orifice 063 TOOLS REQUIRED Power drill 2 Phillips bit high temp silicone sealan...

Page 30: ...d safely WARNING C Leg Leveling System Figure 8 8 Thread Allen bolts through nuts until flush The Allen bolts and nuts are included in the component pack inside the appliance firebox Figure 8 9 Slide...

Page 31: ...FOR QUARTET AND SOLITAIRE FACE OPTIONS Figure 8 11 Solitaire Front Quartet Front Spacer NOTE The brick supplied with the Topaz is not an optional accessory The brick must be installed for safe and pr...

Page 32: ...d side panel and support the other end with one hand Install the remaining side panel and bend over the tabs to hold it in place Rest top panel baffle on sides and slide top panel baffle left or right...

Page 33: ...e your log set application reinstall the glass and the front of the unit H Mineral Wool Follow ember placement instructions in manual Do NOT place embers directly over burner ports Replace ember mater...

Page 34: ...Place blower under appliance Attach blower from front with 4 screws to blower bracket Figure 8 27 Install snap disc in bracket Attach bracket to fire box with 5 16 in wrench Figure 8 28 Connect elect...

Page 35: ...ire Topaz 7009 113 Rev N 5 13 Figure 8 31 Blower Wiring Diagram Fan Speed Control Thermal Disc 110 VAC Power Cord BLAC K Bushing Strain Relief GREEN BLACK Ground Fan Assembly BLACK BLACK WHITE WHITE W...

Page 36: ...in place K Damper Adjustment Make adjustment Let appliance warm up before adjusting Loosen screw using a Phillips head screwdriver Pivot the vertical damper adjustor in 1 4 in 6mm incre ments while o...

Page 37: ...baffle adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper posi tion Ensure that the flow of combustion and ventilation air is not obstructed front grilles...

Page 38: ...ower from the appliance 4 Open the door of the appliance May need to remove face front first 5 Push in gas control knob slightly and turn clockwise to the OFF position Do not force 6 Wait five 5 minut...

Page 39: ...ors Smoke and odors may be irritating to sensitive individuals CAUTION Prevent accidental appliance operation when not attended Unplug or remove batteries from remote control if absent or if appliance...

Page 40: ...mocouple connection at the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and...

Page 41: ...aust gases back into the system Check for proper vent connection at flue collar and all vent joints c Horizontal vent improperly pitched The horizontal vent cap should slope down only enough to preven...

Page 42: ...or slamming glass Do NOT use abrasive cleaners Use a hard water deposit glass cleaner on white film Do NOT clean glass when hot Turn off appliance after 3 4 hours of operation and ALLOW TO COOL Remov...

Page 43: ...s sary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top inspect for plugged...

Page 44: ...eference only For clearances refer to Section 3 Figure 12 1 Appliance Dimensions B C A K L M N O D E F G H I J Location Inches Millimeter Location Inches Millimeter A 27 3 8 695 I 19 3 8 492 B 7 178 J...

Page 45: ...in 235mm 6 1 2 in 165mm 6 5 8 in 168mm 17 24 in 432 610mm 11 3 4 in 298mm 5 3 4 in 146mm 6 5 8 in 168mm 6 3 8 in 162mm 6 1 2 in 165mm 9 5 8 in 244mm 6 5 8 in 168mm 6 1 2 in 165mm 6 3 8 in 162mm 9 5 8...

Page 46: ...SLP36 BK 46 DVA 36B 48 Pipe Length Galvanized SLP48M 46 DVA 48 48 Pipe Length Black SLP48 BK 46 DVA 48B Adjustable Length 3 6 Black SLP6A BK Adjustable Length 3 6 Galvanized SLP6AM Adjustable Length...

Page 47: ...R e v i t a r o c e D Firestop Spacer Ceiling Firestop SLP FSM 46DVA FS Flex Trap Cap with Firestop SLP FLEX TRAP Flex Trap Cap with Firestop and 30 Flex Pipe SLP FLEX TRAP30 Masonry Chimney Conversi...

Page 48: ...gany 839 1370 5 02 7 04 Solitarie Porcelian Midnight Blue 839 1381 7 02 4 03 Solitarie Porcelain Midnight Blue 839 1381 7 03 5 04 Color SKU No Mfg Dates Quartet Matte Black 839 1290 3 02 Active Quarte...

Page 49: ...12 Y 1 4 x 1 1 2 7000 466 12 Y 6 Grill Rear Vent Black 844 9830 Mahogany 844 9860 Sienna Bronze RV TPZ CSB No longer available RV TPZ CWL 7 Grill Top Vent Black 468 0040MBK Mahogany 468 0040PMH Sienn...

Page 50: ...14 Face Assembly Solitaire Solitaire Face Black 7009 007MBK 15 Door Assembly W Glass 7011 003 Glass Assembly 23 44 W x 14 32 H 7011 015 Y Glass Gasket Field Cut to Size Qty 10 Ft 844 3010 Y Tape Door...

Page 51: ...Lp Lp Orifice Conversion Label Leveling Assembly Snap Disc Bracket Owners Manual Warranty Card Black 7009 003 Mahogany 7009 016 Sienna Bronze 7009 019 Willow 7009 020 Leveling Assembly 7000 000 Miner...

Page 52: ...12 oz Can Qty 1 Sienna Bronze Espresso PAINT1 CSB CES Y Willow Tuscan Olive PAINT1 CWL CTO Y Piezo Ignitor Black Knob 291 513 Y Plate Damper 468 0360 Regulator Conversion Sit NG 230 1570 Y Relief Doo...

Page 53: ...ostat 842 0370 Y Wire Harness 455 7240 Y Firescreen Quartet Front Only 844 9360 Warming Shelves Black 844 9780 Mahogany 844 9810 Sienna Bronze WSLG CSB Willow WSLG CWL Smart Batt Il 841 0970 Smart Sta...

Page 54: ...se In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer dist...

Page 55: ...D ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surfa...

Page 56: ...ncluded Read understand and follow these instruc tions for safe installation and operation Leave this manual with party responsible for use and operation R Quadra Fire Topaz 7009 113 Rev N 5 13 Printe...

Reviews: