and Welcome to the Quadra-Fire Family

!

Hearth & Home Technologies welcomes you to our tradition 
of excellence!  In choosing a Quadra-Fire appliance, you 
have our assurance of commitment to quality, durability, 
and performance.

This commitment begins with our research of the market, 
including ‘Voice of the Customer’ contacts, ensuring we 
make products that will satisfy your needs. Our Research 
and Development facility then employs the world’s most 
advanced technology to achieve the optimum operation 

of our stoves, inserts and fi replaces.  And yet we are old-
fashioned when it comes to craftsmanship.  Each appliance 
is meticulously fabricated and gold and nickel surfaces are 
hand-fi nished for lasting beauty and enjoyment.  Our pledge 
to quality is completed as each model undergoes a quality 
control inspection.    

We wish you and your family many years of enjoyment in 
the warmth and comfort of your hearth appliance.  Thank 
you for choosing Quadra-Fire.

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION: HANGING ON A CHAIN ON BACK OF APPLIANCE

Manufactured Date

Serial Number

Model Name

Test Lab & Report No.

Report No. / Rapport Numéro 

061-S-19B-5 

MODEL / MODÈLE: TOPAZ 

VENTED GAS FIREPLACE HEATER FOURNAISE AU GAZ AVEC 

VENTILATION.  NOT FOR USE WITH SOLID FUEL / NE PAS UTILISER 

AVEC LE COMBUSTIBLE SOLIDE. 

 

 

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ÉTIQUETTE 

Made in U.S.A. / Fait Aux États-Unis 

A.  Side of stove top to side wall 

6.5" (152 mm) 

Du coté du poêle au coté du mur 

B.  Rear of stove top to back wall 

6" (100 mm) 

Le contrôle arrière au mur arrière 

C.  Corner of stove top to side wall 

1" (152 mm) 

Du Coin du poêle du mur 

D.  Minimum Alcove Height 

54" (1372 mm) 

Hauteur minimum du plancher au plafond 

E.  Maximum Alcove Depth 

36" (914 mm) 

Profondeur maximale de l'alcôve 

F.  Minimum Alcove Width 

40"(915 mm) 

Largeur minimum de l'alÔve 

G. Mantle clearance from stove top                                           23"(584mm)                                                             Espace libre du poêle au manteau 

 

  

SERIAL  NO

.

 

This appliance equipped only for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’ (0-1370m). In USA for Altitudes above 2000’, the vent 
configuration, orifice, or combination of both may need to be changed. See Owner’s Manual for information on making these changes.
This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if none, follow  National Fuel Gas Code ANSI Z223.1, 
or Canadian Installation Codes, CAN/CGA-B149  in Canada. Install and use only in accordance with manufacturer’s installation and operating instructions. NOTE: Have the gas 
supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, installation 
must be performed by a licensed plumber or gas fitter.)
Cet appareil est équipé pour les altitudes de 0-2000’ (0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500’ (0-1370m). Pour les altitudes au dessus de 2000’ 
aux États-Unis, la configuration du ventilateur, son orifice ou les deux peuvent possiblement avoir à être changé. Voyez le manuel du propriétaire pour les informations sur 
ces changements. Cet appareil doit être installé en accord avec les codes locaux, s’il-y-a lieu (et approuvé par dans la République de Massachusetts); sinon lisez au National 
Fuel Gas Code ANSI Z223.1, ou aux code courant d'installation Installez et utilisez en accords avec les instructions d’installation et d’opération du manufacturier.

 

REMARQUE: 

Le conduit gaz doit être installé conformément aux codes de construction locaux. L'installation doit être effectuée par un technicien qualifeé et/ou muni d'une licence de manière à 
respecter les règlements municipaux. (Dans la République de Massachusetts, l'installation doit être effectuée par un plombier ou un installateur d'appareils à gaz agrée.)

 

This appliance must be installed in accordance with the current Standard CAN/CSA Z240 MH, Mobile Housing or with Manufactured Home Construction and Safety Standard, 
Title 24 CFR, Part 3280, or when such standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installation Standard.
 WARNING: Do not operate the appliance until all sections have been assembled and installed in accordance with the manufacturer's instructions.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maisons mobiles ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard.  Si ces 
normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
AVERTISSEMENT: Ne pas utiliser l'appareil tant que toutes les sections n'ont pas ete assemblees et installees selon les instructions du fabricant.
This appliance must be properly connected to a venting system in accordance with the manufacturer's installation instructions.
Cet apprareil doit être correctement raccordé à un système d'évacuation, conformément aux instructions du fabricant

FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE 
Blower Electrical Rating / Évaluation du Ventilateur Électrique: 
115 V., 1.5 Amps, 60 Hz, 150 Watts 

Thermal Efficiency / Efficacité Thermique*            85% NG (blower on / avec ventilateur allumé) 

                                                                                    85% LP  (blower on / avec ventilateur allumé) 

* With Maximum horizontal length. / Avec longueur horizontale maximum. 

P.4.1-02 Canada Minimum pipe

 

(P.4.1-02 Le canada tuyau minimum) 

 

62.98% NG / 64.14% LP 

APPROVED FOR CANADA AND USA TO: 
ANSI Z21.88a-2000 / CSA 2.33a-M-00 Vented Gas Fireplace Heaters, and 
applicable sections of UL307b Gas Burning Heating Appliances for 
Manufactured Homes and Recreational Vehicles, CAN/CGA 2.17-M91 
“Gas Fired Appliances for use at High Altitudes.” This appliance is 
manufactured for operation with Natural Gas.   

APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS: 
ANSI Z21.88a-2000 / CSA 2.33a-M-00 Fournaises au Gaz avec Ventilation, 
et les sections applicable de UL 307b Appareils de Chauffage Au Gaz pour 
les Maisons Mobiles et les Véhicules Motorisés, CAN/CGA 2.17-M91 “Gas 
Fired Appliances for use at High Altitudes”. 
Cet appareil est manufacturé pour l’opération avec le Gaz Naturel. 

Date of Manufacture / Date du Manufacturier 

2008

2009

2010

Feb Mar Apr May Jun  Jul Aug Sep Oct Nov Dec 

Jan 

A

A

E

A

B

C

D

F

A

C

250-7141 

G

 

1445 North HIghway 

Colville, WA 99114 

www.quadrafire.com 

 

HEARTH: A non-combustible hearth pad is not required. However, the floor beneath the stove must be stable, level, and strong enough to support the stove without a tipping hazard. 
CHEMINÉE: Un coussinet non-combustible de cheminée n’est pas exigé. Cependant, le plancher en dessous du poêle doit être droit, à niveau et assez fort pour 
supporter le poêle sans le hasard de basculer. 

Top Vent/Rear Vent: 
Input Rate on “HI” (BTU/Hr) 

  

Input Rate on “LO” (BTU/Hr) 
Maximum Output (BTU/Hr)** 
Main Burner Orifice (DMS) 
Minimum Inlet Pressure (Inches W.C.) 
Maximum Inlet Pressure (Inches W.C.) 
Manifold Pressure on “HI” (Inches W.C.) 
**Max Venting, Blower On 

For use with Natural Gas 

Usage au Gaz Naturel 

0-2000’ 

39,500 
26,500 
33,600 

.125” 

4.5“ 
7.0” 
3.5” 

 

For use with Propane 

Usage au Gaz Propane 

0-2000’ 

38,000 
30,500 
32,500 

.073” (49DMS) 

11“ 
14” 
10” 

 

 

Bouche Supérieure/Conduit postérieur: 
Puissance Évaluée à “HI” (BTU/Hr) 
Puissance Évaluée à “LO” (BTU/Hr) 
Puissance Maximum (BTU/Hr)** 
Orifice du Brûleur Principal 
Pression Minimum de la Valve (pouces W.C.) 
Pression Maximum de la Valve (pouces W.C.) 
Pression du Collecteur d’ Échappement à “HI” (pouces W.C.) 
** Ventilation Maximum, Ventilateur Allumé 

 

SAMPLE 

SA

MP

LE

 

Portland

Barcode

Summary of Contents for TOPAZ 839-1290

Page 1: ...y or death This appliance may be installed as an OEM installation in manufactured home USA only or mobile home and must be installed in accordance with the manufacturer s instructions and the manufact...

Page 2: ...chnicien qualife et ou muni d une licence de mani re respecter les r glements municipaux Dans la R publique de Massachusetts l installation doit tre effectu e par un plombier ou un installateur d appa...

Page 3: ...onversions 23 B Gas Pressures 25 C Gas Connection 26 Section 7 Electrical Information A Recommendation for Wire 27 B Connecting to the Appliance 27 C Standing Pilot Ignition System Wiring 27 Section 8...

Page 4: ...ass WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas con...

Page 5: ...t terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBST...

Page 6: ...Remove log set and component pack from firebox Report to your dealer any parts damaged in shipment particularly the condition of the glass Read all of the instructions before starting the instal latio...

Page 7: ...ce to all clearance specifications in manual WARNING B Clearances Figure 3 1 Model A B C D E F G Topaz Inches 6 1 2 6 1 54 36 40 23 Millimeters 165 152 25 1372 914 1016 584 NOTE Flooring beneath appli...

Page 8: ...LOWEST DISCHARGE OPENING Roof Pitch H Min Ft Flat to 6 12 1 0 Over 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12 2 0 Over 9 12 to 10 12 2 5 Over 10 12 to 11 12 3 25 Over 11 12 to 12 12 4 0...

Page 9: ...AX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2 3 x Q ACTUAL 4 caps 12 feet 1 2 x Q ACTUAL QMIN termination caps x 3 RMA X 2 termination caps xQACTUAL N 6 inches non vinyl side...

Page 10: ...gonal runs have both vertical and horizontal vent aspects when calculating the effects Use the rise for the vertical aspect and the run for the horizontal aspect See Figure 5 1 Two 45 elbows may be us...

Page 11: ...s 6 in 152mm Horizontal sections require a 1 4 in 6mm rise for every 12 in 305mm of horizontal travel Exterior Vent Diameter 6 5 8 in 168mm Inner Vent Diameter 4 in 102mm Horizontal sections require n...

Page 12: ...wist lock adapter is built into the appliance at the factory Wall thickness may vary Remember to include wall thickness in minimum clearances when figuring venting lengths for your installation needs...

Page 13: ...grade i e basement application proper drainage must be provided to prevent water from entering the snorkel termination Do not backfill around snorkel termination HOT HOT WOOD SCREW WALL THIMBLE Step 4...

Page 14: ...op to vinyl standoff SCREWS Apply sealant to all four sides VINYL SIDING Figure 5 8 8 in 203mm 7 in 178mm 7 in 178mm 6 in 152mm Figure 5 7 NOTE Some termination caps may cause the vent pipe to be off...

Page 15: ...p 2 Set the gas appliance in its desired location Drop a plumb bob down from the ceiling to the position of the appliance flue exit and mark the location where the vent will penetrate the ceiling Dril...

Page 16: ...equirements as outlined in the current CAN CGA B149 Installation Codes in Canada the National Fuel Gas Code NFPA 54 ANSI Z223 1 in USA or local codes Note that for steep roof pitches the vent height m...

Page 17: ...amed and sheetrocked with standard construction materials however refer to these installation instructions for the minimum allowable clearance between the outside of the vent pipe and the combustible...

Page 18: ...thing Step 5 Using tin snips cut the support box from the top corners down to the roofline and fold the resulting flaps over the roof sheathing Figure 5 18 Before nailing it to the roof run a bead of...

Page 19: ...Connect the flex pipe to the retro connector and attach with sheet metal screws Step 6 Push the flex pipe back up into the ceiling support box center the retro connector and attach it to the support...

Page 20: ...x Liner Pipe Length Optional Chimney Liner Termination Cap Co Axial to Co Linear Connector 30 ft 9m of 3 in 76mm Flex Liner Exhaust Section Pipe Length Optional 4 ft 1m of 3 in 76mm Flex Liner Air Int...

Page 21: ...gth extended to its nominal length Be sure to leave 2 3 in 51 76mm of flex above the existing chimney to allow for connection to the termination kit Step 3 Secure the flashing to the top of the masonr...

Page 22: ...the top adapter to the flashing Use three sheet metal screws through the side of the top adapter into the flange on the flashing Figure 5 28 Twist lock the high wind termination cap on to the top ada...

Page 23: ...nd lifting the burner out Figure 6 3 Remove the three screws on the front of the burner support Set screws aside Figure 6 5 Remove the main burner orifice using a 5 8 in wrench and replace the orifice...

Page 24: ...move the rods and adapter cap Fire Risk Explosion Risk Disconnect any electrical cords and turn off gas supply to unit before proceeding if converting fuel on an appliance already fully installed WARN...

Page 25: ...ow Proper input pressures required for optimum appliance per formance gas line sizing requirements need to be followed from NFPA51 WARNING Fire Risk Explosion Hazard High pressure will damage valve Di...

Page 26: ...local building codes if any If not follow ANSI Z223 1 Instal lation should be done by a qualified installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts in...

Page 27: ...ppliance 4 Use low resistance thermostat wire for wiring from igni tion system to the wall switch and thermostat 5 Use the following chart for wire sizing 6 Keep wire lengths as short as possible by r...

Page 28: ...trols Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Shock hazard Replace damaged wire with type 105O C rated wire Wire must have high temperature ins...

Page 29: ...lling as indi cated in Figure 8 6 Figure 8 2 Remove inner collar adapter KIT CONTENTS Rear vent grille NG orifice 113 LP orifice 063 TOOLS REQUIRED Power drill 2 Phillips bit high temp silicone sealan...

Page 30: ...d safely WARNING C Leg Leveling System Figure 8 8 Thread Allen bolts through nuts until flush The Allen bolts and nuts are included in the component pack inside the appliance firebox Figure 8 9 Slide...

Page 31: ...FOR QUARTET AND SOLITAIRE FACE OPTIONS Figure 8 11 Solitaire Front Quartet Front Spacer NOTE The brick supplied with the Topaz is not an optional accessory The brick must be installed for safe and pr...

Page 32: ...d side panel and support the other end with one hand Install the remaining side panel and bend over the tabs to hold it in place Rest top panel baffle on sides and slide top panel baffle left or right...

Page 33: ...e your log set application reinstall the glass and the front of the unit H Mineral Wool Follow ember placement instructions in manual Do NOT place embers directly over burner ports Replace ember mater...

Page 34: ...Place blower under appliance Attach blower from front with 4 screws to blower bracket Figure 8 27 Install snap disc in bracket Attach bracket to fire box with 5 16 in wrench Figure 8 28 Connect elect...

Page 35: ...ire Topaz 7009 113 Rev N 5 13 Figure 8 31 Blower Wiring Diagram Fan Speed Control Thermal Disc 110 VAC Power Cord BLAC K Bushing Strain Relief GREEN BLACK Ground Fan Assembly BLACK BLACK WHITE WHITE W...

Page 36: ...in place K Damper Adjustment Make adjustment Let appliance warm up before adjusting Loosen screw using a Phillips head screwdriver Pivot the vertical damper adjustor in 1 4 in 6mm incre ments while o...

Page 37: ...baffle adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper posi tion Ensure that the flow of combustion and ventilation air is not obstructed front grilles...

Page 38: ...ower from the appliance 4 Open the door of the appliance May need to remove face front first 5 Push in gas control knob slightly and turn clockwise to the OFF position Do not force 6 Wait five 5 minut...

Page 39: ...ors Smoke and odors may be irritating to sensitive individuals CAUTION Prevent accidental appliance operation when not attended Unplug or remove batteries from remote control if absent or if appliance...

Page 40: ...mocouple connection at the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and...

Page 41: ...aust gases back into the system Check for proper vent connection at flue collar and all vent joints c Horizontal vent improperly pitched The horizontal vent cap should slope down only enough to preven...

Page 42: ...or slamming glass Do NOT use abrasive cleaners Use a hard water deposit glass cleaner on white film Do NOT clean glass when hot Turn off appliance after 3 4 hours of operation and ALLOW TO COOL Remov...

Page 43: ...s sary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top inspect for plugged...

Page 44: ...eference only For clearances refer to Section 3 Figure 12 1 Appliance Dimensions B C A K L M N O D E F G H I J Location Inches Millimeter Location Inches Millimeter A 27 3 8 695 I 19 3 8 492 B 7 178 J...

Page 45: ...in 235mm 6 1 2 in 165mm 6 5 8 in 168mm 17 24 in 432 610mm 11 3 4 in 298mm 5 3 4 in 146mm 6 5 8 in 168mm 6 3 8 in 162mm 6 1 2 in 165mm 9 5 8 in 244mm 6 5 8 in 168mm 6 1 2 in 165mm 6 3 8 in 162mm 9 5 8...

Page 46: ...SLP36 BK 46 DVA 36B 48 Pipe Length Galvanized SLP48M 46 DVA 48 48 Pipe Length Black SLP48 BK 46 DVA 48B Adjustable Length 3 6 Black SLP6A BK Adjustable Length 3 6 Galvanized SLP6AM Adjustable Length...

Page 47: ...R e v i t a r o c e D Firestop Spacer Ceiling Firestop SLP FSM 46DVA FS Flex Trap Cap with Firestop SLP FLEX TRAP Flex Trap Cap with Firestop and 30 Flex Pipe SLP FLEX TRAP30 Masonry Chimney Conversi...

Page 48: ...gany 839 1370 5 02 7 04 Solitarie Porcelian Midnight Blue 839 1381 7 02 4 03 Solitarie Porcelain Midnight Blue 839 1381 7 03 5 04 Color SKU No Mfg Dates Quartet Matte Black 839 1290 3 02 Active Quarte...

Page 49: ...12 Y 1 4 x 1 1 2 7000 466 12 Y 6 Grill Rear Vent Black 844 9830 Mahogany 844 9860 Sienna Bronze RV TPZ CSB No longer available RV TPZ CWL 7 Grill Top Vent Black 468 0040MBK Mahogany 468 0040PMH Sienn...

Page 50: ...14 Face Assembly Solitaire Solitaire Face Black 7009 007MBK 15 Door Assembly W Glass 7011 003 Glass Assembly 23 44 W x 14 32 H 7011 015 Y Glass Gasket Field Cut to Size Qty 10 Ft 844 3010 Y Tape Door...

Page 51: ...Lp Lp Orifice Conversion Label Leveling Assembly Snap Disc Bracket Owners Manual Warranty Card Black 7009 003 Mahogany 7009 016 Sienna Bronze 7009 019 Willow 7009 020 Leveling Assembly 7000 000 Miner...

Page 52: ...12 oz Can Qty 1 Sienna Bronze Espresso PAINT1 CSB CES Y Willow Tuscan Olive PAINT1 CWL CTO Y Piezo Ignitor Black Knob 291 513 Y Plate Damper 468 0360 Regulator Conversion Sit NG 230 1570 Y Relief Doo...

Page 53: ...ostat 842 0370 Y Wire Harness 455 7240 Y Firescreen Quartet Front Only 844 9360 Warming Shelves Black 844 9780 Mahogany 844 9810 Sienna Bronze WSLG CSB Willow WSLG CWL Smart Batt Il 841 0970 Smart Sta...

Page 54: ...se In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer dist...

Page 55: ...D ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surfa...

Page 56: ...ncluded Read understand and follow these instruc tions for safe installation and operation Leave this manual with party responsible for use and operation R Quadra Fire Topaz 7009 113 Rev N 5 13 Printe...

Reviews: