ISO18000-6C(EPC-G2) tag operate 
 
Click “EPCTag operate” from menu as follow : 

 

   

Tag Identify 

 

 

 
 

  Select identity tag times

default as continue

, tag identify the time

default is 

10ms

then click “Start” button, reader get to tag identify status, when read the tag 

will show as below: 

 

EPC multi tag identify success and detail record 

 

Identify tag total quantity 

  EPC GEN2 Read and Write 

Need Stop “Identify Tag” operation before to read/write data to the tag   

 

 
 

Summary of Contents for OMT724

Page 1: ...e stop bit and no parity bit Data rate can be 9600 19200 57600 and 115200 TCP IP This reader supports RJ45 Ethernet interface DB15 definition DB15 pin assignment Pin 1 2 3 4 5 6 7 8 function Output 2...

Page 2: ...low GND Input 2 Input 1 Specification PC enquiry Reader input Input status command as below Head Addr Len Cmd Check 0x0A FF 0x02 0x2E C7 When reader received it will get response as below 1 When 2 Inp...

Page 3: ...state of the appointed address EPC GEN2 ISO18000 6C tag Multi tag identification search all the tags in the detection range and read the EPC supports 96 bits EPC Single tag initialization define the...

Page 4: ...e DEMO software Click on EXIT to close the program DEMO reader operation Connect Reader with PC through RS232 cable a Serial Port connection select the correct Com Port and Baud rate 9600 115200 optio...

Page 5: ...can change the IP Address Mask code gateway e g 196 168 000 001 for Gateway need input 3 digit value section e g 000 Below error message will be found if input an incorrect format e g 0 or 00 5 click...

Page 6: ...st select power parameter and frequency China 902 928MHz AMERICA ISM902 928MHz EUROPEAN ISM865 868MHz then click Set button as chart B Chart A chart B Antenna set and query Query working antenna click...

Page 7: ...k ASCII option is valid read the data is ASCII code if not valid then it is hex data format Tag Write write ISO180006B tag s Data First must select one tag identify the tag first and then select selec...

Page 8: ...t as continue tag identify the time default is 10ms then click Start button reader get to tag identify status when read the tag will show as below EPC multi tag identify success and detail record Iden...

Page 9: ...ion bar as below EPC read success EPC GEN2 Write Select membank Membank option include KILL PWD ACCESS PWD EPC CODE TID CODE USER DATA different tag with different memeory then select address Address...

Page 10: ...Lock Tag button if lock success the information bar will show below as below Note once the tag locked it can t unlock only can lock the bank EPC G2 KILL Select bank Bank to KILL PWD in Passeord bar in...