background image

 

unit off. (Activates after 
5 minutes.) 

 

Adju 

CHXX=XXX 

Adjust Value of Each 
Channel 

Info 

DriT 

XXXC 

Driver Temperature 

Set 

Rest 

Rest 

Reset 

 

Move 

RPan                ON/

OFF 

RTilt                  ON/

OFF

 

Degr                 630/540 
Enco                 

ON

/OFF 

Mode                

Mod1

/Mod2 

Reverse Pan 
Reverse Tilt 
Choose Pan Degree 
Encoder Wheel 
Choose Pan/Tilt Mode 

 

UI 

Mic                    0~99%, 

60% 

Sign                  Close/

Hold

/Auto/Music 

Fan                   

Auto Speed

/High Speed 

Hibe                  OFF, 01M~99M, 

15M 

Back                 02~60M, 

02M 

Flip                   ON/

OFF 

User                  

Use1

/Use2 

Mic Sensitivity 
Signal Mode 
Fan Mode 
Hibernate Time 
Backlight Time 
Flip Display 180

° 

DMX Mode (St/Ex) 

 

Cali 

Code                 XXX 
CHXX                 XXX 

Password (050) 
Calibrate Channel 

 

Ver 

X1.0.0 

IC Version 

 

load 

ON/

OFF

 

Reload Default 

 

 
CLEANING AND MAINTENANCE

 

The operator needs to make sure that safety­related and machine­technical installations are inspected by an 
expert after every four years in the course of an acceptance test. 

 

The operator needs to make sure that safety­relating and machine­technical installations are inspected by a 
skilled person once a year. 

 

The following points must be considered during the inspection: 
1) All screws used for installing the devices or parts need to be tightly connected and not corroded. 
2) There must not be any deformations on housings, fixations, and installation spots (ceiling, suspension, 

trussing). 

3) Mechanically moving parts like axles must not show any traces of wearing (e.g. material abrading or 

damages) and must not rotate unbalanced. 

4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables), or 

sediments. Further instructions depending on the installation spot and usage need to be adhered by a skilled 
installer and any safety problems have to be removed. 

 

 

We recommend a frequent cleaning of the device. Please use a moist, lint­free cloth. Never use alcohol or 
solvents! 

16 of 18 

 

Summary of Contents for onyxpro 75

Page 1: ...Tel 253 395 9500 Fax 253 395 9494 6403 South 208th Street Kent WA 98032 KEEP THIS MANUAL FOR FUTURE NEEDS 1 of 18...

Page 2: ...arge variety of lighting sound truss and effects Since 1986 we have been providing quality and affordable lighting products to North America We are confident that our excellent products will meet your...

Page 3: ...mage Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time Do not connect more than 8 units together in a single power chain If...

Page 4: ...n cars and heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must only be operated in an altitude between 20 and 2000m over sea level Never use the devic...

Page 5: ...e 23mm inside 18mm 7 open custom interchangeable position for rotating gobo wheel Real indexable and gobo shaking Distinctive gobo animation effect Features DMX channels 11 14 Color wheel 8 1 colors S...

Page 6: ...bjective lens 2 Arm 3 Base 4 Handle 5 Wireless indicator 6 Display 7 MODE ESC 8 Down Button 9 Up Button 10 Enter button 11 3 PIN DMX input socket 12 3 PIN DMX output socket 13 Power input 14 Power out...

Page 7: ...onstructed in a way that no part of the installation can fall down if the main attachment fails When rigging de rigging or servicing the fixture staying in the area below the installation place on bri...

Page 8: ...systems need to be used The projector must never be fixed swinging freely in the room Caution Projectors may cause severe injuries when crashing down If you have doubts concerning the safety of a poss...

Page 9: ...g system Insert the end in the quick link and tighten the fixation screw The maximum drop distance must never exceed 20cm A safety bond which already holds the strain of a fall or which is defective m...

Page 10: ...f the controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX ch...

Page 11: ...connected to the power supply the fixture starts running During the reset the motors are trimmed and the device is ready to use Stand Alone operation In the Stand Alone mode the device can be used wi...

Page 12: ...to ensure proper transmission on the DMX data link DMX Protocol St Ex Name Function DMX 1 1 Pan Pan Coarse 0 255 2 Pan Fine Pan Fine 0 255 2 3 Tilt Tilt Coarse 0 255 4 Tilt Fine Tilt Fine 0 255 3 5 Mo...

Page 13: ...13 Cyan Orange Color 14 Orange Color 15 Orange Magenta Color 16 Magenta Color 17 Magenta White Indexed w Bounce Color 01 White Red Color 03 Red Blue Color 05 Blue Green Color 07 Green Yellow Color 09...

Page 14: ...obo 6 Gobo 7 Forward Wheel Spin Stop to Fast Reverse Spin Stop to Fast 0 5 6 11 12 17 18 23 24 29 30 35 36 41 42 47 48 53 54 59 60 65 66 71 72 77 78 83 84 89 90 95 96 97 98 115 116 13 3 134 15 1 152 1...

Page 15: ...mply set the starting address run the pre programmed program or perform a reset Main Menu Browse through the menu by pressing the Mode Down Up and Enter keys Press Enter in order to select the desired...

Page 16: ...years in the course of an acceptance test The operator needs to make sure that safety relating and machine technical installations are inspected by a skilled person once a year The following points m...

Page 17: ...older on the rear panel Step 2 Remove the old fuse from the fuse holder Step 3 Install the new fuse in the fuse holder Step 4 Replace the fuse holder in the housing Should you need any spare parts ple...

Page 18: ...xH 343 x 262 x 455 mm 13 5 x 10 3 x 17 9 Weight 10kg 30 9 lbs Maximum ambient temperature Ta 45 C 113 F Maximum housing temperature TB steady state 60 C 140 F Min distance from flammable surfaces 0 5...

Reviews: