OmniSense G-3 Series User Manual Download Page 6

 

[email protected] 1.805.340.9625 

Page 

3

                                               OmniSense G-3 Series Gateway 

7.  Accessing G-3 Management Web Page 

The G-3 has a built in web server which serves up the 
management web pages.  The management web server can be 
accessed directly using any PC, tablet or smart phone.  To 
connect to the G-3 Management Web Page you must connect 
your PC, smart phone or tablet directly to the G-3 using either 
WiFi 

or

 hard wired Ethernet. 

  Power on gateway and wait for the "Internet" LED to stop 

blinking 

  to connect using WiFi 

  From your PC, tablet or smart phone scan for available 

wireless networks 

  Connect to SSID "OmniSense" 

  to connect using hard wired Ethernet 

  Connect G-3 Gateway's WAN/LAN port to your PC's 

Ethernet port using Ethernet cable 

  You should see the "WAN/LAN" Link LED go on solid or 

blink 

  open a web browser and enter "

http://omnisense

" in the 

address field 

  You should then see a login page (see 

Error! Reference 

ource not found.

) prompting for username and password.  

Use the default username and password from the label on 
the bottom of the gateway.  

 

TIP

 - The default username is "root" and the default 

password is the gateway ID.  Note password and 
username are case sensitive and all letters are lower 
case. 

 

TIP

 - From the login page with no username or password 

required you can quickly get useful status like current 
cellular signal strength and number of active sensors 
since gateway was turned on.  Bookmark this page for 
easy access.  

 
 

As a general warning you should not change any settings 

outside of what is described in this manual.  You can restore 

factory defaults by holding down the reset button for 20 

seconds.  

 

Summary of Contents for G-3 Series

Page 1: ...G 3 Series Gateway User Manual OmniSense LLC 72 Sams Point Road Ladys Island SC 29907 USA http www omnisense com support omnisense com 1 805 340 9625 1 843 522 0350 Revision 1 0 Released 5 7 2013 ...

Page 2: ......

Page 3: ...NECTION 5 8 2 WIFI INTERNET CONNECTION 5 8 3 G 3 C X 3G CELLULAR DATA INTERNET CONNECTION 6 8 3 1 G 3 C GSM Using provided SIM card 6 8 4 G 3 C GSM INSERTING YOUR OWN SIM CARD 6 8 5 GSM CONNECTION STATUS 7 9 USING G 3 GATEWAY IN DATALOGGING MODE 7 10 CREATE A MONITORING ACCOUNT 8 11 ASSIGNING GATEWAY S TO A JOB SITE 8 12 INSTALLING SENSORS 8 13 VIEW SYSTEM DATA ONLINE 8 14 NETWORK CONFIGURATION 9 ...

Page 4: ... G 3 series gateway is compatible with all OmniSense and GE HygroTrac sensors This manual describes how to get your G 3 gateway online and begin monitoring 3 What is Included Description G 3 series Data Acquisition Gateway Detachable Antenna with RP SMA connector for Sensor Communication Detachable Antenna with RP SMA connector for Cellular Communication G 3 C x models only USB Power Supply 5VDC 1...

Page 5: ... 1 LEDs POWER when on indicates power is ON CELLULAR FLASHES when receiving a cellular signal Flash rate varies to indicate signal strength Faster is better signal slower is worse signal WiFi ON when WiFi is enabled blinks to indicate data activity WAN LAN ON when Ethernet is enabled blinks to indicate data activity INTERNET When FLASHING indicates gateway is powering up When ON indicates the G 3 ...

Page 6: ...et port using Ethernet cable You should see the WAN LAN Link LED go on solid or blink open a web browser and enter http omnisense in the address field You should then see a login page see Error Reference ource not found prompting for username and password Use the default username and password from the label on the bottom of the gateway TIP The default username is root and the default password is t...

Page 7: ...support omnisense com 1 805 340 9625 OmniSense G 3 Series Gateway Page 4 Figure 2 G 3 Management Login Web Page ...

Page 8: ... not working Check the troubleshooting guide in section 15 and or our web site forum at shop omnisense com for troubleshooting tips 8 1 Wired Ethernet Internet Connection Typically this is zero configuration and you do not need to access the G 3 Management Web Page when using a wired Ethernet connection Connect the gateway s WAN LAN Ethernet port using the supplied Ethernet cable to your LAN route...

Page 9: ...M card If your G 3 C GSM did not come with a SIM card follow these instructions for inserting your SIM card and configuring your connection Accessing the USB Stick MODEM 1 Open the gateway case by removing the 4 screws on the bottom of the gateway 2 Loosen two red thumb screws 3 Remove USB Stick MODEM to allow for access to SIM slot Inserting the SIM Card see Figure 3 Inserting the SIM Card 1 Skip...

Page 10: ...OmniSense web site s gateway detail page should you need it 8 5 GSM Connection Status The rate at which the Cellular LED flashes varies with signal strength and faster is better The Internet LED comes on when a connection with the OmniSense server has been successfully made more detailed connection status is available on the G 3 Management Web Page which is accessed as described in section 7 9 Usi...

Page 11: ...sh to monitor 11 Assigning Gateway s to a job site after completing the site setup in step 1 you will be on the My Account page Click on jobs Sites to go to your job sites and you should see the job site you just created Click on the Gateways link on that page to manage the gateways assigned to that job site Click on the Add a new gateway button Enter the Gateway ID found on the bottom label of th...

Page 12: ...1 98 if no other DHCP server is detected on the network or it will automatically act as a DHCP client if a DHCP server is detected 15 Troubleshooting PROBLEM SOLUTION Cellular LED Blinking you have signal but Internet LED never comes on not getting internet connection If you are using your own SIM card check your APN Username and Password settings After changing settings you can no longer access y...

Page 13: ...ceiling using 2 built in teardrop mounting eyes WiFi 802 11gn Ethernet 10 100 Mb s 3G Cellular on G 3 C GSM models Huawei E160G USB MODEM US models come with T Mobile SIM Card Sensor Antenna RP SMA omni directional 2 dBi gain Cellular Antenna on G 3 C GSM models RP SMA omni directional 2 dBi gain Sensor transmitter RF power 10 mW Sensor transmitter RF frequency 64 channels in 902 928 MHZ FCC ISM b...

Page 14: ...ment has been tested and found to comply with part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no g...

Page 15: ...ions NOTICE The Industry Canada IC label identifies certified equipment The Department does not guarantee the equipment will operate to the user s satisfaction For EU Models Only Data Acquisition Gateway The G 3 Series Gateway is in conformity with the following standards EN55022 2006 A1 2007 EN 55024 2010 EN60950 1 2006 A11 2009 A1 2010 A12 2011 following the provisions of the 2004 108 EC Electro...

Page 16: ...erein OmniSense LLC makes no warranty representation or guarantee regarding the suitability of its products for any particular application nor does OmniSense LLC assume any liability arising out of the application or use of any product or circuit and specifically disclaims all liability without limitation for consequential or incidental damages The foregoing warranties are exclusive and in lieu of...

Reviews: