UM-003-A OPS243-A User Manual
18
OmniPreSense Corporation
Persistent Memory
–
saves current configuration into flash memory and is retained even if power is
removed.
Command
Name
R/W
Value
A!
Save Configuration
Write
Saves current configuration settings in flash
memory. Upon power loss or recycling power,
the saved configurations will be used as the
default.
A.
Read Settings
Write
Read the current flash settings.
AX
Reset Flash Settings
Write
Will overwrite current saved settings and
return to the factory default settings.