11. Initial Setup
18 www.sinetech.co.za
AC output ON/Off Timer: Set up on/off time for AC output of inverter. If setting is
00:00/00:00, this function is disabled.
Allow to charge battery: This option is automatically determined by setting in “Charging
source”. It cannot be modified here. When “NONE” is selected in the charging source
section, this option becomes unchecked as grey text.
Allow AC to charge battery: This option is automatically determined by setting in
”Charging source”. It cannot be modified here. When “Grid and PV” or “Grid or PV” is
selected in charging source section, this option is default selected. Under Grid-tie mode,
this option is invalid.
Allow to feed into the Grid: This option is only valid under Grid-tie and Grid-tie with
backup modes. Users can decide if this inverter should feed into the grid.
Allow battery to discharge when PV is available: This option is automatically determined
by setting in “Load supply source (PV is available)”. When “Battery” is higher priority
than “Grid” in Load supply source (PV is available), this option is default selected. Under
Grid-tie, this option is invalid.
Allow battery to discharge when PV is unavailable: This option is automatically
determined by setting in “Load supply source (PV is unavailable)”. When “Battery” is
higher priority than “Grid” in Load supply source (PV is unavailable), this option is default
selected. Under Grid-tie mode, this option is invalid.
Allow battery to feed-in to the Grid when PV is available: This option is only valid in
Grid-tie with backup II or Grid-tie with backup III modes.
Allow battery to feed-in to the Grid when PV is unavailable: This option is only valid in
all options of Grid-tie with backup mode.