background image

6  

Fig. 9 

Important

:

 

DO NOT use a hex wrench on the Re-

taining Nuts (7.2), only apply pressure with your 

finger. 

Fig. 10 

Route the cables along one side of the Inner Arm (nearest the wall 

plate), as shown in Fig. 9.  With cables in place, loosely secure the Inner 
Arm cable covers back in place.  

Next, route the cables along the opposite side of the Outer Arm, as shown in 

Fig. 10.  Be sure to leave slack in the cable where it transitions between the 

two sides of the Arm Assembly.  With cables in position, loosely secure the 
Outer Arm cable covers back in place. 

Note: For best system performance, route the AC 
power cable separately from the signal cables. 

With all cables in place, pull the display in and out and check that the arm 

assembly moves freely, without stretching or damaging the cables, and then 

secure the cable covers. 

Step 7 — Using Cable Management 

The Wishbone series cantilevers include a cable management function, where cables can be routed along the length of the 
arm assembly. 

To install cables, you’ll first need to remove the cable covers.  Using a Phillips Head screwdriver on the Retaining Screw 

(7.1) and pushing on the Retaining Nuts (7.2) with your finger, remove the screw assembly (Fig. 8).  Remove the Cable 

Covers (7.3) and set all parts aside. 

Fig. 7 

7.2 

7.1 

7.3 

Retaining Screw 

Fig. 8:

 

Screw Assembly

 

Cover Washer 

Plastic Sleeve 

Step 8 — Adjusting the Display 

The Wishbone series cantilevers provide a wealth of flat panel display adjustment to 
offer the best viewing from a number of seating positions. 

 

Roll Control

Horizontal leveling of the flat panel display.  

Grasp the edge of the display and roll it up or down into a level position. (Fig 11) 

Fig. 11 

 3 

Step 1 — Determine the Mounting Location 

To provide maximum viewing flexibility, the OmniMount Wishbone Series cantilever mounts are capable of a wide range 

of motion, which  allows the flat panel display to be positioned for viewing from many different angles. 

When selecting the mounting location for the display, make sure there is adequate space on all sides of the display, consid-

ering the dimensions (H x W) of your particular flat panel display model.  

Step 2 — The Installation Template 

The Installation Template is designed to make the installation of the wall plate faster, easier and more accurate.  In addi-

tion, the template can be used to locate and mount any 

required electrical boxes for routing AC power and A/V 

signals to the display.  Finally, the template includes a 

built in dust channel to reduce the clean up chores from 

mounting the  CL-X. 

 

Assembling the Dust Channel: 

Locate the supplied mounting template. (Fig. 1) 
Fold the dust collector along the marked lines: 

a.  Fold main channel up. 
b.  Crease and fold the tab sections inward. 
c. 

Fold outer portion of tab around the back 
of the guide, and then insert tab into slot. 

Step 3 — Mounting to the Wall 

Follow the instructions based upon your mounting surface:  
3a Wooden 

Stud 

3b Concrete/Masonry 
3c Cinder 

Block 

Step 3a — Mounting to Wooden Studs 

The CL-X can be mounted onto two wooden studs, with center to center distances between 15” and 
17” (38—43 cm). 
 
Using an electronic stud finder (Fig 2), locate the center of the two wooden studs at the desired mount-

ing location.  Mark the stud center positions directly onto the wall.  Extend the stud center lines, and 

then draw a horizontal line between the studs to represent where you wish the center of the screen to be 
located.  Measure and mark the center of this horizontal line. 
 
Insert supplied thumbtack into center cross-hair on template, and then remove the tape strip from the back of the tem-

plate.  Pin the template to the center mark on the wall.  Using a level (bubble or laser), level the guide, and then press the 
adhesive backing against the wall to hold the guide in place.  
 
Note: Depending upon the roughness of the surface, you may need to hold the template in place with an application of 
blue painters tape. 
 
Using a 1/4” (6 mm) drill bit, drill 6 pilot holes into the center of the studs (through the mounting hole cut-out sections of 
the template), down to a depth of 3” (76 mm). 
 
Note: For best results from the dust channel, press and hold the template against the wall about 2” (50 mm) from where 
you are drilling. 
If installing electrical boxes for an AC outlet and/or A/V signal cables, carefully remove the perforated sections of the 
guide and then mark the wallboard.  This mark will define the area in which electrical boxes may be installed. 
 
Carefully remove the guide from the wall, and discard.  Note: Be sure to hold the guide in an upright position so as not to 
spill the collected dust. 

Fig. 2 

Fig. 1 

Summary of Contents for Wishbone Series

Page 1: ...nt Systems disclaims liability for any diffi culties arising from the interpretation of information contained in these instructions If OmniMount products are used for purposes other than their original intent OmniMount its distributors and retailers shall not be held responsible or liable for injuries or property damage direct indirect or consequential which may arise from the inability to use thi...

Page 2: ...ithout manual adjustment yet can still be moved with minimal effort Fig 12 Grasp the upper and lower edges of the display and then push or pull the display to the desired tilt angle Fig 13 To lock the tilt angle tighten the Tilt Levers 12 1 se curely Fig 12 For heavier displays never fully release the Tilt Knob without fully supporting the display 12 1 Loosen Tighten The Tilt Lever includes a ratc...

Page 3: ...esigned to make the installation of the wall plate faster easier and more accurate In addi tion the template can be used to locate and mount any required electrical boxes for routing AC power and A V signals to the display Finally the template includes a built in dust channel to reduce the clean up chores from mounting the CL X Assembling the Dust Channel Locate the supplied mounting template Fig ...

Page 4: ...st Insert wall anchors into the mounting holes and lightly tap them flush to the wall with a hammer Fig 3 WARNING Cinder Block must meet ASTM C 90 specifications Mount to solid portion of block generally 1 from the sides NEVER drill into mortar joints Use standard drill set on slow speed high torque setting DO NOT use hammer drill on cinder block Verify that you have a minimum of 1 3 8 of actual c...

Reviews: