User Manual V4.2
37
7.4 Instructions of Safety Standard selection when power-up
1) Attentions before the operation:
Only perform this operation when the volt
age value displayed on Omnik inverter’s LCD falls
between 80V and 300V for 1.0kW inverter or between 150V and 450V for 1.5kW/2.0kW
inverters.
Only perform this operation when the accumulative generated electricity is less than 1KWh.
2) Operation steps are as following:
a. Power on the inverter with only DC side connected, while disconnecting cables of AC
side.
b.
Press the Function button until the LCD displays inverter’s model and hold the button for
5 seconds or more when the LCD displays the current Safety Standard. Change the
standard by pressing the Function button one at a time.
Function button