User Manual V4.2
30
Cable preparation
(ill.9) Important: Cables with class 2, 5
or 6 construction can be connected. It is
advantageous to use tinned conductors.
It is unadvisable to use non-tinned cables
of type H07RN-F, since with oxidised
copper wires the contact resistances of
the crimp connection may exceed the
permitted limits.
Check dimension b according to the
following table:
(ill.10) Strip cable insulation. L = 6-7, 5
mm. Take care not to cut individual
strands.
Recommended tool:
Stripping pliers PV-AZM,Order
No.32.6027
Crimping
(ill.11) Notes to the operation ofthe
crimping pliers, see¬MA251-def
(www.multicontact.com)
(ill.12) Push the crimped contact into the
socket resp. plug insulator until it
engages. Pull lightly on the lead to check
that the metal part has engaged.