General Specifications 

Power Requirements 

Power Supply Voltage 

 30Vdc (ripple < 5%) 

Average Current 

2.7 Watt peak(excluding I/O) 

1 Watt typical 

User Configuration 

Configuration Software 

Omniset Configuration Untility 
(free download from website 

www.omniflex.com

) 

Advanced User 

Programming 

Advanced customisation of the 

product is possible using the 
built in EziForth Programming 

Language. Consult the factory 
for your application. 

Environmental Conditions 

Storage Temperature 

-25

 85 

C (-13

 185

F) 

Operating Temperature 

-10

 60 

C (+14

 140

F) 

Full GSM Spec. compliance  -10

 50 

C (+14

 122

F) 

Weight 

Packed/Unpacked 

350gm/250gm approx. 

 

Compliance with Standards 

Safety 

EN 60950 

Emissions 

EN 55011, Group I, Class A 

Immunity 

 ESD 

IEC 61000-4-2:2001, level 3 

Immunity 

 RF Fields  IEC 61000-4-3:2003, level 3 

Immunity 

  

Fast Transients 

IEC 61000-4-4:2004 
2 kV 

 DC power port 

1 kV 

 input/output lines 

 
 
 
 

 

Ordering Information 

ORDER CODE  DESCRIPTION 
C2363A-11-0  Teleterm Silent Sentry with Quad band 850/900/1800/1900MHz GSM/GPRS modem. 
C2363A-12-0  Teleterm Silent Sentry with GSM/GPRS/EDGE/HSPA modem (3G HSPA compliant) 
NOTE 

All Teleterm Silent Sentry’s supplied with the following:

 

 

Internal network modem 

 

External stub antenna 

 

Serial programming cable 

ACCESSORIES 
M1831A 

Serial Programming cable (as a spare) 

 
 
 
 
 
© Copyright Omniflex 2019 

Summary of Contents for Teleterm Silent Sentry C2330B

Page 1: ...ar update message capability ensures the ability of the Silent Sentry to react to alarms when they occur The Silent Sentry is easily configurable by the user using the free Omniset configuration software Using Omniset PRO the Silent Sentry can even be configured remotely over the GSM CDMA network The Silent Sentry can be connected to your existing alarm annunciator system and can even be used to r...

Page 2: ...ard not supplied Ensure that the SIM card holder is properly closed See the User Manual for more detailed instructions 3 Replace the top blue cover 4 Connect the stub antenna supplied Do not over tighten Finger tight is quite acceptable 5 Power up the unit 9 30Vdc 6 Once you have downloaded the Omniset software install the software on to a PC equipped with a serial port or USB to serial port conve...

Page 3: ...1 12 13 14 15 16 OK RUN TX1 RX1 TX2 RX2 PROG Pushbefore removingcard Onlyremovecard when lightis off Link Act 10 100 Antenna RJ25 Programming Port RS232 485 Serial Port Diagnostic Lights LEDs I O Terminals I O Indicators C2330B TELETERM Silent Sentry Height including serial cable 155 37 46 5 152 40 5 7 5 45 89 5 Input Output Wiring 70 ...

Page 4: ...8 12 Yes 0 5Vdc Yes 9 13 Yes 0 5Vdc Yes 10 14 Yes 0 5Vdc Yes 11 15 Yes 0 30Vdc 12 16 Yes 0 30Vdc Note 1 See the Specifications section of this document for detailed specifications of each I O point option Note 2 All 0 30V analogue inputs have increased resolution over the range 0 6V equivalent to the 0 5V inputs Note 3 All Digital Inputs can be configured as Pulse Counters or Hours Counter Note 4 ...

Page 5: ...e for all messages Once a message has been sent to all recipients the message will not be sent again for at least the duration set in the Hold off time setting SMS ALARM ACKNOWLEDGMENT Method All outstanding Alarms in the Silent Sentry can be acknowledged by sending an SMS to the Silent Sentry with the words Ack or Yes in the message MAXIMUM SMS MESSAGES PER HOUR As further protection against an a...

Page 6: ...pe Voltage Input referenced to 0V supply Range 0 30Vdc software configurable to smaller ranges such as 1 5Volts Accuracy 0 15 of reading 6mV from 0 to 5 5V 0 15 of reading 30mV from 5 5 to 30V Resolution 6mV from 0 to 5 5 Volts nominal 10 bits 33mV from 5 5 to 30Volts nominal 10 bits As an Analogue Input I O Points 3 to 10 Type Voltage Input referenced to 0V supply Range 0 5 5Vdc software configur...

Page 7: ...ec compliance 10 C 50 C 14 F 122 F Weight Packed Unpacked 350gm 250gm approx Compliance with Standards Safety EN 60950 Emissions EN 55011 Group I Class A Immunity ESD IEC 61000 4 2 2001 level 3 Immunity RF Fields IEC 61000 4 3 2003 level 3 Immunity Fast Transients IEC 61000 4 4 2004 2 kV DC power port 1 kV input output lines Ordering Information ORDER CODE DESCRIPTION C2363A 11 0 Teleterm Silent S...

Reviews: