Omniflex Teleterm Silent Sentry C2330B Installation Manual Download Page 3

Page 3 

 

 

 

General Layout 

 

 

 

 

Mechanical Dimensions 

 

 

 
 
 
 
 
 

9-30Vdc

+

-

1 2 3 4 5 6 7 8 9 10 11 12

Press card in

to release.

P

O

R

T

 1

NET

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

OK RUN

TX1 RX1

TX2 RX2

P

R

O

G

Push before 

removing card. 

Only remove card 

when             light is 

off.

Link/Act

10/100

Antenna

RJ25

Programming 

Port

RS232/485

Serial Port

Diagnostic

Lights (LEDs)

I/O Terminals

I/O Indicators

C2330B

TELETERM

Silent Sentry

Height including serial cable

155

37

46.5

152.40

5

7.5

4

5

8

9

.5

Input/Output

Wiring

70

Summary of Contents for Teleterm Silent Sentry C2330B

Page 1: ...ar update message capability ensures the ability of the Silent Sentry to react to alarms when they occur The Silent Sentry is easily configurable by the user using the free Omniset configuration software Using Omniset PRO the Silent Sentry can even be configured remotely over the GSM CDMA network The Silent Sentry can be connected to your existing alarm annunciator system and can even be used to r...

Page 2: ...ard not supplied Ensure that the SIM card holder is properly closed See the User Manual for more detailed instructions 3 Replace the top blue cover 4 Connect the stub antenna supplied Do not over tighten Finger tight is quite acceptable 5 Power up the unit 9 30Vdc 6 Once you have downloaded the Omniset software install the software on to a PC equipped with a serial port or USB to serial port conve...

Page 3: ...1 12 13 14 15 16 OK RUN TX1 RX1 TX2 RX2 PROG Pushbefore removingcard Onlyremovecard when lightis off Link Act 10 100 Antenna RJ25 Programming Port RS232 485 Serial Port Diagnostic Lights LEDs I O Terminals I O Indicators C2330B TELETERM Silent Sentry Height including serial cable 155 37 46 5 152 40 5 7 5 45 89 5 Input Output Wiring 70 ...

Page 4: ...8 12 Yes 0 5Vdc Yes 9 13 Yes 0 5Vdc Yes 10 14 Yes 0 5Vdc Yes 11 15 Yes 0 30Vdc 12 16 Yes 0 30Vdc Note 1 See the Specifications section of this document for detailed specifications of each I O point option Note 2 All 0 30V analogue inputs have increased resolution over the range 0 6V equivalent to the 0 5V inputs Note 3 All Digital Inputs can be configured as Pulse Counters or Hours Counter Note 4 ...

Page 5: ...e for all messages Once a message has been sent to all recipients the message will not be sent again for at least the duration set in the Hold off time setting SMS ALARM ACKNOWLEDGMENT Method All outstanding Alarms in the Silent Sentry can be acknowledged by sending an SMS to the Silent Sentry with the words Ack or Yes in the message MAXIMUM SMS MESSAGES PER HOUR As further protection against an a...

Page 6: ...pe Voltage Input referenced to 0V supply Range 0 30Vdc software configurable to smaller ranges such as 1 5Volts Accuracy 0 15 of reading 6mV from 0 to 5 5V 0 15 of reading 30mV from 5 5 to 30V Resolution 6mV from 0 to 5 5 Volts nominal 10 bits 33mV from 5 5 to 30Volts nominal 10 bits As an Analogue Input I O Points 3 to 10 Type Voltage Input referenced to 0V supply Range 0 5 5Vdc software configur...

Page 7: ...ec compliance 10 C 50 C 14 F 122 F Weight Packed Unpacked 350gm 250gm approx Compliance with Standards Safety EN 60950 Emissions EN 55011 Group I Class A Immunity ESD IEC 61000 4 2 2001 level 3 Immunity RF Fields IEC 61000 4 3 2003 level 3 Immunity Fast Transients IEC 61000 4 4 2004 2 kV DC power port 1 kV input output lines Ordering Information ORDER CODE DESCRIPTION C2363A 11 0 Teleterm Silent S...