background image

Page 1 

 

 

 

 

 

 

INSTALLATION  GUIDE  

 

Teleterm Silent Sentry 

Model C2330B 

 

The TELETERM ‘Silent Sentry’ is a state

-

of-the-art  Remote  SMS  Alarm  Monitor 

capable  of  monitoring  a  wide  range  of 
input types and sending SMS Alarm and 

status  messages  upon  detection  of  an 

alarm condition. 

The  Silent  Sentry  is  equipped  with  12 
direct  Binary  or  Analogue  Inputs,  plus  a 

Modbus  port  allowing  alarms  from  a 

variety of sources to be monitored. 

Up to 64 different SMS messages can be 
sent. The Silent Sentry can be configured 

for  up  to  10  SMS  message  recipients, 

each  in  one  of  three  escalating  priority 

groups. This allows messages to be sent 
to a selected group of recipients, and if not 

acknowledged within a set time, then sent 

to the second group of recipients, and if 

still  not  acknowledged,  then  sent  to  the 
third group  

of recipients. 

The addition of a regular update message 

capability ensures the ability of the Silent 
Sentry to react to alarms when they occur. 

The Silent Sentry is easily configurable by 

the  user,  using  the  free  Omniset 

configuration  software.  Using  Omniset 
PRO,  the  Silent  Sentry  can  even  be 

configured remotely over the GSM/CDMA 

network. 

The  Silent  Sentry  can  be  connected  to 
your  existing  alarm  annunciator  system 

and  can  even  be  used  to  remotely 

acknowledge  alarms  using  your  mobile 

phone. 
The  Silent  Sentry  provides  an  easy 

solution  to  remotely  monitoring  your 

alarms or even send the Silent Sentry an 

SMS to read a value or control an output. 

Application Examples 

 

Remote Site Monitoring 

 

Computer Rooms 

 

Environmental & Effluent Monitoring 

 

Small Sub-station Monitoring 

 

Facilities Management 

 

Utilities Monitoring 

 

 

 

Features 

 

Receive Text Message Alerts on your phone 

 

Acknowledge Alarms remotely or have them 

escalate to other mobiles 

 

Monitor Digital or Analog Inputs 

 

Send up to 64 different messages 

 

Send up to Recipients 

 

"On-Demand" messages asllow remote 

monitoring & control 

 

Summary of Contents for Teleterm Silent Sentry C2330B

Page 1: ...ar update message capability ensures the ability of the Silent Sentry to react to alarms when they occur The Silent Sentry is easily configurable by the user using the free Omniset configuration software Using Omniset PRO the Silent Sentry can even be configured remotely over the GSM CDMA network The Silent Sentry can be connected to your existing alarm annunciator system and can even be used to r...

Page 2: ...ard not supplied Ensure that the SIM card holder is properly closed See the User Manual for more detailed instructions 3 Replace the top blue cover 4 Connect the stub antenna supplied Do not over tighten Finger tight is quite acceptable 5 Power up the unit 9 30Vdc 6 Once you have downloaded the Omniset software install the software on to a PC equipped with a serial port or USB to serial port conve...

Page 3: ...1 12 13 14 15 16 OK RUN TX1 RX1 TX2 RX2 PROG Pushbefore removingcard Onlyremovecard when lightis off Link Act 10 100 Antenna RJ25 Programming Port RS232 485 Serial Port Diagnostic Lights LEDs I O Terminals I O Indicators C2330B TELETERM Silent Sentry Height including serial cable 155 37 46 5 152 40 5 7 5 45 89 5 Input Output Wiring 70 ...

Page 4: ...8 12 Yes 0 5Vdc Yes 9 13 Yes 0 5Vdc Yes 10 14 Yes 0 5Vdc Yes 11 15 Yes 0 30Vdc 12 16 Yes 0 30Vdc Note 1 See the Specifications section of this document for detailed specifications of each I O point option Note 2 All 0 30V analogue inputs have increased resolution over the range 0 6V equivalent to the 0 5V inputs Note 3 All Digital Inputs can be configured as Pulse Counters or Hours Counter Note 4 ...

Page 5: ...e for all messages Once a message has been sent to all recipients the message will not be sent again for at least the duration set in the Hold off time setting SMS ALARM ACKNOWLEDGMENT Method All outstanding Alarms in the Silent Sentry can be acknowledged by sending an SMS to the Silent Sentry with the words Ack or Yes in the message MAXIMUM SMS MESSAGES PER HOUR As further protection against an a...

Page 6: ...pe Voltage Input referenced to 0V supply Range 0 30Vdc software configurable to smaller ranges such as 1 5Volts Accuracy 0 15 of reading 6mV from 0 to 5 5V 0 15 of reading 30mV from 5 5 to 30V Resolution 6mV from 0 to 5 5 Volts nominal 10 bits 33mV from 5 5 to 30Volts nominal 10 bits As an Analogue Input I O Points 3 to 10 Type Voltage Input referenced to 0V supply Range 0 5 5Vdc software configur...

Page 7: ...ec compliance 10 C 50 C 14 F 122 F Weight Packed Unpacked 350gm 250gm approx Compliance with Standards Safety EN 60950 Emissions EN 55011 Group I Class A Immunity ESD IEC 61000 4 2 2001 level 3 Immunity RF Fields IEC 61000 4 3 2003 level 3 Immunity Fast Transients IEC 61000 4 4 2004 2 kV DC power port 1 kV input output lines Ordering Information ORDER CODE DESCRIPTION C2363A 11 0 Teleterm Silent S...