Collection Timer — set up the value for the polling period for the Terminal, its
connected modules and external devices. The available value range is from 15 to 240
seconds.
Go to the “Operation Mode for Ignition Off and Power On” and select one of the
following:
“Collect all data”, collecting and transmitting data in the same manner as when the
ignition is on.
“Collect all data except GPS”, collecting and transmitting data selected during the
Terminal configuration, except for the GPS module data.
“Collect Data during jolting”, monitoring the state of the panic button and
accelerometer. When the accelerometer readings change by more than 0.2 g, or
when the panic button is pressed, the Terminal switches to 'Collect All Data' mode
and proceeds to transmit data to the Communication Server for the next 5 minutes.
When selecting “Collect all data during jolting”, configure the following settings:
“Collect all data”, with this parameter enabled, the Terminal switches to “Collect all
data” mode and collects and transmits data to the communication server when the
time entered in the “Period of Data Transmission to Server” expires. Having
transmitted all available data, the Terminal reverts to “Collect data during jolting”
mode.
Period of data transmission to server, select the time interval in between the
Terminal's connection sessions to the server. The available values range from 1 to 6
hours at 1-hour increments.