Input/Output
This submenu provides level adjustments for the audio inputs and the absolute peak operating level of the Analog
XLR, Composite MPX, AES-3 (AES/EBU) and Livewire outputs. Choices governing the selection of the input
audio source (Analog, AES Digital or Livewire) and signal mode (Stereo or Mono) are also found within these
submenus. There is also a setting to disable Livewire.
These I/O settings are generally “set once and forget” parameters, usually adjusted during initial installation and
then left alone. These I/O settings are not saved with a processing preset but can be saved, loaded, deleted or
renamed as “I/O Configurations” using options available in this submenu.
Mtr Select (Meter Select)
Selects whether the
Input
levels,
Analog Out
put levels,
AES
/EBU
Out
put levels or
LW
(Livewire)
Out
put
levels
are displayed on the front panel L & R LED bargraph meters.
Input
There are eleven controls under the heading “Input” and each will be explained in the order in which they
appear in the menu:
<-Exit
Click on this option to return to the
Input/Output
menu.
Input Src (Input Source)
Allows the selection of
Analog
,
AES/EBU
(digital) or
Livewire
as the primary input source to the
OmniaONE.
Fover Time (Failover Time)
Failover Time is a feature that when set to a value other than zero (disabled) allows the
OmniaONE to automatically select another input source if the currently selected one fails.
Failover Time is the amount of time that will elapse after the failure of audio on the primary input
source before the unit makes the decision to switch to the secondary (failover) input source. For
instance, if Failover Time is set for 5 seconds and the primary audio source fails, 5 seconds later
the unit will switch to the secondary audio input if that input is active. If, at any time, audio is
restored on the primary input (for 1 second, continuously), the unit will switch back to the primary
audio input. It will remain with the primary input unless another failure is detected.
Fover Src (Failover Source)
Failover Source selects which audio input:
Analog
,
AES/EBU
(digital) or
Livewire
will serve as
the secondary audio input. Note that the audio input that is selected under Input Source (above)
will always be the Primary audio input. A source selected under Failover Source will always be
the secondary source.
28