5.1.3
Check the communication with the FASTRACK Supreme
To check the communication with the FASTRACK Supreme, do the following operations:
•
Connect the RS232 link between the DTE (port COM) and the FASTRACK Supreme (DCE).
•
Configure the RS232 port of the DTE as follows:
Bits per second:
115.200 bps
,
Data
bits:
8
,
Parity:
None
,
Stop
bits:
1
,
Flow
control:
hardware
.
•
Using a communication software such as a HyperTerminal, enter the
AT
↵
command. The
response of the FASTRACK Supreme must be
OK
displayed in the HyperTerminal window.
•
If the communication cannot be established with the FASTRACK Supreme, do the following:
Check the RS232 connection between the DTE and the FASTRACK Supreme
(DCE),
Check the configuration of the port COM used on the DTE.
•
Example of AT commands which can be used after getting started the FASTRACK Supreme:
AT+CGMI
:
FASTRACK Supreme answer is "WAVECOM MODEM" when serial
link is OK.
AT+CPIN=xxxx
:
to enter a PIN code xxxx (if activated).
AT+CSQ
: to verify the received signal strength.
AT+CREG?
: to verify the registration of the FASTRACK Supreme Plug & Play on
the network.
ATD<phone number>;
: to initiate a voice call.
ATH
: to hang up (end of call).
For further information on these AT commands and their associated parameters, refer to "AT
Commands Interface Guide" [6].
5.1.4
Reset the FASTRACK Supreme
To reset the FASTRACK Supreme, a hardware reset signal is available on pin 14 of the Sub HD 15-pin
connector (RESET).
The FASTRACK Supreme reset is carried out when this pin is low for at least 200
μ
s.
Warning This signal has to be considered as an emergency reset only. For further details on the