Fastrack Supreme User Guide
Using the FASTRACK Supreme Plug & Play
confidential ©
Page: 45 / 77
Description
AT commands
FASTRACK Supreme Plug
& Play response
Comment
+CREG: 0,0
FASTRACK Supreme Plug
& Play not registered
on the network, no
registration attempt.
Receiving an
incoming call
ATA OK
Answer
the
call.
OK Communication
established.
+CME ERROR: 11
PIN code not entered (with
+CMEE = 1 mode).
Initiate a call
ATD<phone number>;
(Don’t forget the « ; » at the
end for « voice » call)
+CME ERROR: 3
AOC credit exceeded or a
communication is already
established.
Initiate an
emergency call
ATD112;
(Don’t forget the « ; » at the
end for « voice » call)
OK Communication
established.
Communication
loss
NO
CARRIER
Hang up
ATH OK
Store the
parameters in
EEPROM
AT&W
OK
The configuration settings
are stored in EEPROM.
(1*) The command "AT+CMEE=1" switch to a mode enabling more complete error diagnostics.
5.11
Firmware Upgrade Procedure
The firmware upgrade procedure is used to update the firmware embedded into the FASTRACK Supreme.
That procedure consists in downloading the firmware into internal memories through the RS232 serial link
available on the SUB-D 15-pin connector.