NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE. REFER TO
THIS MANUAL. FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT
A QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.
These appliances are designed to operate on
natural or propane gas only.
Input of appliance is 23,000 BTU/HR.
WARNING: THESE FIREPLACES ARE
VENTED GAS FIREPLACE HEATERS. DO
NOT BURN WOOD OR OTHER MATERIAL
IN THESE APPLIANCES.
Please read and carefully follow all of the instructions found in this manual.
Please pay special attention to the safety instructions provided in this manual.
The Homeowner's Care and Operation Instructions included here will assure that
you have many years of dependable and enjoyable service from this product.
INTRODUCTION
The Fireplace models covered in this manual
are Direct-Vent sealed combustion gas fire-
place heaters designed for residential appli-
cation. Direct-Vent appliances operate with
the combustion chamber completely iso-
lated from the inside atmosphere. All air for
combustion is brought in from the outside
and exhaust gases are vented through the
same direct vent, vent system.
These millivolt appliances are designed to
operate on either natural or propane gas and
may be easily converted to the use of either
gas type with the conversion kit provided. A
millivolt gas control valve with piezo ignition
system provides safe, efficient operation. Ex-
ternal electrical power is required to operate
the optional electrically powered components
if installed. Electrical power must be wired
during appliance installation.
S'assurer que le brùleur et le compartiment
des commandes sont propres. Voir les in-
structions d'installation et d'utilisation qui
accompagnent l'appareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
Due to high temperatures the appliance should
be located out of traffic and away from furni-
ture and draperies. Locate furniture and win-
dow coverings accordingly.
These appliances comply with National Safety
Standards and are tested and listed by Omni-
Test Laboratories (Report No. 116-F-13-4) to
ANSI Z21.88-2002 (in Canada, CSA-2.33-
2002), and CAN/CGA-2.17-M91 in both USA
and Canada, as vented gas fireplace heaters.
Installation must conform to local codes. In the
absence of local codes, installation must com-
ply with the current National Fuel Gas Code,
ANSI Z223.1 (NFPA 54). (In Canada, the current
CAN/CGA B149 installation code.) Electrical
wiring must comply with local codes. In the
absence of local codes, installation must be in
accordance with the National Electrical Code,
NFPA 70 - (latest edition). (In Canada, the
current CSA C22.1 Canadian Electric Code.)
For additional installation requirements when
these appliances are to be installed as an OEM
installation in a manufactured home, refer to
the manufactured home construction and
safety standard, Title 24, Part 3280 or stan-
dard for installation in manufactured homes,
CAN/CSA Z240MH.
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.
Nominal operating pressures for the manifold
side of the gas control system are; 3.5 inches
water column (0.87 kPa) for natural gas models
and 10 inches water column (2.49 kPa) for
propane gas models.
Do not use these appliances if any part has
been under water. Immediately call a qualified,
professional service technician to inspect the
appliance and to replace any parts of the
control system and any gas control which
have been under water.
Ne pas se servir de cet appareil s'il a été plongé
dans l'eau, complètement ou en partie. Appeler
un technicien qualifié pour inspecter l'appareil et
remplacer toute partie du système de contrôle et
toute commande qui ont été plongés dans l'eau.
Test gage connections are provided on the
front of the gas control valve (identified IN for
the manifold side and OUT for inlet pressure).
Gas
Orifice
Type
Size
Elevation
0 - 4500'
(0 - 1370 m)
0 - 4500'
(0 - 1370 m)
Natural
Propane
#54
(.055)
(.090)
TABLE OF CONTENTS
Introduction ..................................... page
2
General Information ......................... page
2
Operation/Care of Your Appliance .... page
3
Control Compartment Access .......... page
3
Variable Flame Adjustment .............. page
3
Glass Cleaning ................................. page
4
Maintenance .................................... page
4
Front Glass Enclosure Panel,
Removal and Installation ............... page
4
Maintenance Schedule ..................... page
5
Burner Adjustments ......................... page
6
Flame Appearance and Sooting ....... page
6
Adjustment ...................................... page
6
Log Placement ................................. page
7
Rockwool Placement ....................... page
7
Volcanic Stone Placement ............... page
7
Appliance Checkout ......................... page
7
Wiring Diagrams .............................. page
8
Warranty .......................................... page
8
Replacement Parts .......................... page
8
Product Reference Information ....... page
8
Accessory Components ................... page
9
Troubleshooting Guide ..................... page 11
Lighting Instructions ....................... page 12
Replacement Parts List ..................... page 14
GENERAL INFORMATION
Note:
Installation and repair should be per-
formed by a qualified service person. The
appliance should be inspected annually by a
qualified professional service technician.
More frequent inspections and cleanings
may be required due to excessive lint from
carpeting, bedding material, etc. It is im-
perative that the control compartment, burn-
ers and circulating air passage ways of the
appliance be kept clean.