9
9 to install fixed-plate for limit magnetic steel.
Installation of fixed-plate for limit magnetic steel: use clutch key to release clutch like fig.10.
Move the gate manually to the open limit and close limit,mark the points on the rack, then fix the
magnet bracket at the limit points on the rack, then close clutch for automatic control. Regulate
the position of fixed plate for limit magnetic steel till the door can open and close properly, and
fasten the fixed-plate for limit magnetic steel finally.
Warning:
Maintenance operations and repairs can be only performed
by qualified technicians. Our company will not bear any legal
liability for non-technicians operations.
Ⅵ
. USER GUIDE:
6-1 User need to have a regular check whether the door is sliding smoothly,
add lubrication grease on the sliding rack regularly.
Ⅷ
. Common faults and removal methods:
(
Non professional is forbidden to touch the line and components on the control board so as to
avoid unnecessary damage)